Pulsed thrust measurements using electromagnetic calibration techniques

被引:18
|
作者
Tang, Haibin [1 ]
Shi, Chenbo [1 ]
Zhang, Xin'ai [1 ]
Zhang, Zun [1 ]
Cheng, Jiao [1 ]
机构
[1] Beijing Univ Aeronaut & Astronaut, Sch Astronaut, Beijing 100191, Peoples R China
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2011年 / 82卷 / 03期
关键词
PLASMA THRUSTERS; IMPULSE BALANCE; STAND;
D O I
10.1063/1.3567803
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A thrust stand for accurately measuring impulse bits, which ranged from 10-1000 mu Ns using a noncontact electromagnetic calibration technique is described. In particular, a permanent magnet structure was designed to produce a uniform magnetic field, and a multiturn coil was made to produce a calibration force less than 10 mN. The electromagnetic calibration force for pulsed thrust measurements was linear to the coil current and changed less than 2.5 parts per thousand when the distance between the coil and magnet changed 6 mm. A pulsed plasma thruster was first tested on the thrust stand, and afterward five single impulse bits were measured to give a 310 mu Ns average impulse bit. Uncertainty of the measured impulse bit was analyzed to evaluate the quality of the measurement and was found to be 10 mu Ns with 95 parts per thousand credibility. (C) 2011 American Institute of Physics. [doi: 10.1063/1.3567803]
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Pulsed thrust measurements using laser interferometry
    Cubbin, EA
    Ziemer, JK
    Choueiri, EY
    Jahn, RG
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (06): : 2339 - 2346
  • [2] Springback calibration using pulsed electromagnetic field
    Golovashchenko, SF
    [J]. NUMISHEET 2005: PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE AND WORKSHOP ON NUMERICAL SIMULATION OF 3D SHEET METAL FORMING PROCESSES, PTS A AND B, 2005, 778 : 284 - 285
  • [3] CALIBRATION TECHNIQUES FOR ELECTROMAGNETIC FLOWMETER
    MAKIN, GS
    BERGEL, DH
    WELBOURN, RB
    [J]. BRITISH JOURNAL OF SURGERY, 1968, 55 (01) : 74 - &
  • [4] Investigation on the measurements of averaging thrust for pulsed thrusters
    Wang, Guang-Yu
    Hong, Yan-Ji
    [J]. Tuijin Jishu/Journal of Propulsion Technology, 2009, 30 (05): : 638 - 640
  • [6] Pulsed RF Calibration for NVNA Measurements
    Roblin, Patrick
    Ko, Youngseo
    Jang, Haedong
    Teyssier, Jean Pierre
    [J]. 80TH ARFTG MICROWAVE MEASUREMENT CONFERENCE: ADVANCES IN WIRELESS COMMUNICATIONS TEST AND MEASUREMENTS, 2012,
  • [7] Techniques for fisheye lens calibration using a minimal number of measurements
    Mundhenk, TN
    Rivett, MJ
    Liao, XQ
    Hall, EL
    [J]. INTELLIGENT ROBOTS AND COMPUTER VISION XIX: ALGORITHMS, TECHNIQUES, AND ACTIVE VISION, 2000, 4197 : 181 - 190
  • [8] CALIBRATION CHARACTERISTICS OF PULSED-FIELD ELECTROMAGNETIC FLOWMETER
    BECK, R
    MORRIS, JA
    ASSALI, NS
    [J]. AMERICAN JOURNAL OF MEDICAL ELECTRONICS, 1965, 4 (02): : 87 - &
  • [9] Design, calibration and error analysis of a piezoelectric thrust dynamometer for small thrust liquid pulsed rocket engines
    Xing, Qin
    Zhang, Jun
    Qian, Min
    Jia, Zhenyuan
    Sun, Baoyuan
    [J]. MEASUREMENT, 2011, 44 (02) : 338 - 344
  • [10] Output Force Characterization of the Electromagnetic Calibration Device for Low Thrust Measurement
    Chang, Hao
    Zhou, Weijing
    Hong, Yanji
    Ye, Jifei
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70