Experimental investigation on thermoelectric generator with non-uniform hot-side heat exchanger for waste heat recovery

被引:91
|
作者
Lu, Xing [1 ]
Yu, Xingfei [1 ]
Qu, Zuoming [1 ]
Wang, Qiuwang [1 ]
Ma, Ting [1 ]
机构
[1] Xi An Jiao Tong Univ, MOE, Key Lab Thermofluid Sci & Engn, Xian 710049, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Thermoelectric generator; Hot-side heat exchanger; Stream-wise temperature drop; Non-uniform configuration; Power output; LONGITUDINAL VORTEX GENERATORS; HYDRAULIC PERFORMANCE; POWER GENERATION; NUMERICAL-MODEL; OPTIMIZATION; SYSTEM; PLATE; FLOW; FIN; RESISTANCE;
D O I
10.1016/j.enconman.2017.08.030
中图分类号
O414.1 [热力学];
学科分类号
摘要
In typical gas-to-liquid thermoelectric generators for waste heat recovery, the stream-wise gas temperature drop in the hot-side heat exchanger leads to the decrease of power output of the whole system. Denser fins are usually arranged on the downstream of the hot-side heat exchanger to improve the uniformity of temperature field and thus the total power output performance of thermoelectric generators when the steam-wise temperature drop is small, but it is not benificial when the steam-wise temperature drop is large. This work investigates the effect of configuration of winglet vortex generators on the performance of thermoelectric generator system. Three sets of hot-side heat exchangers, including a heat exchanger with smooth channel, a heat exchanger with uniform configuration of winglet vortex generators and a heat exchanger with non-uniform configuration of winglet vortex generators, are tested in a gas-to-liquid thermoelectric generators experimental system. The hot-side Reynolds number ranges from 3000 to 6400 and the hot-side inlet temperature is within 523-553 K. The experimental results show that the total and net power output of thermoelectric generator under matched load resistance with uniform heat exchanger can respectively outperform that with smooth heat exchanger by 97.5% and 77.7% in average, whereas that with non-uniform heat exchanger by 189.1% and 177.4% in average. Since the uniform and non-uniform heat exchangers have the same number but different configuration of winglet vortex generators, this kind of active cascade control of heat transfer enhancement elements is proved to be effective in improving the power output of thermoelectric generator system without increasing pumping power.
引用
收藏
页码:403 / 414
页数:12
相关论文
共 50 条
  • [1] Performance enhancement of the motorcycle exhaust thermoelectric generator - Optimization of the hot-side heat exchanger configuration
    Hong, Thong Duc
    Pham, Minh Quang
    Huynh, Khai Quoc
    Tran, Khoi Quang
    [J]. CASE STUDIES IN THERMAL ENGINEERING, 2023, 51
  • [2] USE HOT-SIDE PRECIPITATOR WITH CO BOILER WASTE HEAT RECOVERY
    BIBBO, PP
    PEACOS, MM
    [J]. HYDROCARBON PROCESSING, 1975, 54 (09): : 149 - 150
  • [3] Experimental Study on a Thermoelectric Generator for Industrial Waste Heat Recovery Based on a Hexagonal Heat Exchanger
    Quan, Rui
    Li, Tao
    Yue, Yousheng
    Chang, Yufang
    Tan, Baohua
    [J]. ENERGIES, 2020, 13 (12)
  • [4] Experimental investigation of a novel heat pipe thermoelectric generator for waste heat recovery and electricity generation
    Tang, Simiao
    Wang, Chenglong
    Liu, Xiao
    Su, Guanghui
    Tian, Wenxi
    Qiu, Suizheng
    Zhang, Qihao
    Liu, Ruiheng
    Bai, Shengqiang
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2020, 44 (09) : 7450 - 7463
  • [5] Analysis of the fins geometry of a hot-side heat exchanger on the performance parameters of a thermoelectric generation system
    Borcuch, Marcin
    Musial, Michal
    Gumula, Stanislaw
    Sztekler, Karol
    Wojciechowski, Krzysztof
    [J]. APPLIED THERMAL ENGINEERING, 2017, 127 : 1355 - 1363
  • [6] Waste heat recovery through plate heat exchanger based thermoelectric generator system
    Wang, Tongcai
    Luan, Weiling
    Wang, Wei
    Tu, Shan-Tung
    [J]. APPLIED ENERGY, 2014, 136 : 860 - 865
  • [7] Effect of non-uniform heat flux on solar thermoelectric generator
    Ge, Minghui
    Xuan, Zhiwei
    Zhang, Guoyin
    Zhao, Yuntong
    Zhao, Yulong
    [J]. ENERGY REPORTS, 2022, 8 : 296 - 301
  • [8] EXPERIMENTAL INVESTIGATION OF HEAT TRANSFER ACROSS A THERMOELECTRIC GENERATOR FOR WASTE HEAT RECOVERY FROM AUTOMOBILE EXHAUST
    Pandit, Jaideep
    Thompson, Megan
    Ekkad, Srinath V.
    Huxtable, Scott
    [J]. PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE - 2013, VOL 1, 2014,
  • [9] Thermoelectric Generator with Passive Biphasic Thermosyphon Heat Exchanger for Waste Heat Recovery: Design and Experimentation
    Araiz, Miguel
    Casi, Alvaro
    Catalan, Leyre
    Aranguren, Patricia
    Astrain, David
    [J]. ENERGIES, 2021, 14 (18)
  • [10] Experimental investigation of waste heat recovery potential from car radiator with thermoelectric generator
    Abderezzak, B.
    Randi, S.
    [J]. THERMAL SCIENCE AND ENGINEERING PROGRESS, 2020, 20 (20)