Inter-laboratory comparison of a fatigue test

被引:0
|
作者
Holmgren, M [1 ]
Johansson, K [1 ]
Johnson, E [1 ]
Svensson, T [1 ]
机构
[1] Fraunhofer Chalmers Res Ctr Ind Math, Gothenburg, Sweden
来源
MATERIALPRUFUNG | 2005年 / 47卷 / 09期
关键词
D O I
10.3139/120.100683
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
This paper describes a fatigue testing inter-lab oratory comparison between six Nordic laboratories, which performed fatigue tests on steel specimens. The specimens were tested with three different stress levels (maximum stress) and with a load ratio R = S-min/S-max = 0.1. Each laboratory tested four specimens at each stress level. The participating laboratories reported the results together with the uncertainty of measurement. The calculated results showed a significant difference between laboratories. However, when the differences in modelling were taken into consideration, no significant differences between the laboratories remained. Significant problems connected with calculations of uncertainty of measurement were detected. One of the major conclusions from the study is that it is of great importance how fatigue tests are reported, e.g. the method of modelling. Better knowledge of how to report fatigue tests, including uncertainty of measurement, as well as a more generally accepted way of reporting such tests - and especially how to treat run-outs would be a great improvement for the customers of the laboratories.
引用
收藏
页码:529 / 533
页数:5
相关论文
共 50 条
  • [1] Inter-laboratory measurements and inter-laboratory cooperation
    Mudronja, V
    Stepanic, J
    Medic, S
    [J]. MEASURE AND QUALITY CONTROL IN PRODUCTION, 2004, 1860 : 745 - 750
  • [2] Inter-laboratory comparison of three earplug fit-test systems
    Byrne, David C.
    Murphy, William J.
    Krieg, Edward F.
    Ghent, Robert M.
    Michael, Kevin L.
    Stefanson, Earl W.
    Ahroon, William A.
    [J]. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2017, 14 (04) : 294 - 305
  • [3] THE CHEMAQUA INTER-LABORATORY COMPARISON PROGRAM
    MATTINGLEY, BI
    [J]. TRACE ELEMENTS IN NEW ZEALAND : ENVIRONMENTAL, HUMAN AND ANIMAL, 1989, : 275 - 285
  • [4] INTER-LABORATORY COMPARISON OF FLUOROCARBON MEASUREMENTS
    RASMUSSEN, RA
    [J]. ATMOSPHERIC ENVIRONMENT, 1978, 12 (12) : 2505 - 2508
  • [5] INTER-LABORATORY COMPARISON OF NORTRIPTYLINE LEVELS
    BURROWS, GD
    DAVIES, B
    MAGUIRE, KP
    NORMAN, TR
    SCOGGINS, BA
    HULLIN, RP
    BURCH, J
    [J]. BIOCHEMICAL MEDICINE, 1978, 20 (01): : 125 - 127
  • [6] An Inter-Laboratory Comparison of NVNA Measurements
    Salter, Martin
    Stant, Laurence
    Buisman, Koen
    Nielsen, Troels
    [J]. INTERNATIONAL WORKSHOP ON INTEGRATED NONLINEAR MICROWAVE AND MILLIMETRE-WAVE CIRCUITS (INMMIC), 2018,
  • [7] CONDUCTING AN INTER-LABORATORY STUDY OF A TEST METHOD
    不详
    [J]. MATERIALS PROTECTION, 1965, 4 (05): : 50 - &
  • [8] PROFICIENCY TESTING FOR AIR POLLUTION TEST LABORATORIES BY INTER-LABORATORY COMPARISON SCHEMES
    Debiasi, R.
    Nicolau, M.
    Mitran, E.
    Nicolescu, I.
    Danciulescu, V.
    Stanescu, G. B.
    [J]. JOURNAL OF ENVIRONMENTAL PROTECTION AND ECOLOGY, 2006, 7 (01): : 204 - 211
  • [9] INAA laboratory results evaluation of inter-laboratory analysis test
    Mohamed, Nader M. A.
    El-Nor, Asmaa G. Abo
    Soliman, Mohamed
    Aal, Ahmed A. Abdel
    Shaat, M. K.
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2010, 285 (02) : 321 - 329
  • [10] INAA laboratory results evaluation of inter-laboratory analysis test
    Nader M. A. Mohamed
    Asmaa G. Abo El-Nor
    Mohamed Soliman
    Ahmed A. Abdel Aal
    M. K. Shaat
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 2010, 285 : 321 - 329