Comparison of hydrophilic interaction and reversed phase liquid chromatography coupled with tandem mass spectrometry for the determination of eight artificial sweeteners and common steviol glycosides in popular beverages

被引:21
|
作者
Kubica, Pawel [1 ]
Namiesnik, Jacek [1 ]
Wasik, Andrzej [1 ]
机构
[1] Gdansk Univ Technol, Fac Chem, Dept Analyt Chem, Narutowicza 11-12, PL-80233 Gdansk, Poland
关键词
HILIC-MS/MS; Artificial sweeteners; Steviol glycosides; HILIC method development; ACESULFAME-K; REBAUDIANA; FOODS; SACCHARIN; CYCLAMATE;
D O I
10.1016/j.jpba.2016.01.006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Hydrophilic interaction liquid chromatography (HILIC) coupled with tandem mass spectrometry (MS/MS) was used to separate artificial and natural sweeteners approved for use in European Union (EU). Among three tested HILIC columns (BlueOrchid PAL-HILIC, Ascentis Express Si and Acclaim (TM) Trinity (TM) P2) the last one was selected for the development of HILIC method due to the best results obtained with it. Early eluting and coeluting compounds in HILIC (acesulfame-K, saccharin, cyclamate, sucralose and aspartame) were successfully separated by the HILIC-based approach for the first time. The developed HILIC method allows for determination of all high potency sweeteners in one analytical run. The calibration curves for all analytes had good linearity within the tested ranges. The limits of detection and quantitation were in the range 0.81-3.30 ng/mL and 2.32-9.89 ng/mL, respectively. The obtained recoveries used for trueness and precision estimation were from 98.6% to 106.2% with standard deviation less than 4.1%. Sample preparation was reduced to a necessary minimum and contained only proper dilution and centrifugation. More than twenty samples of beverages were analyzed with the developed HILIC method. Finally, the chromatographic parameters of peaks (reduced retention time, width at baseline, width at 50% of peak height, tailing factor and efficiency) obtained in HILIC mode and in RPLC mode were compared. Developed HILIC method along with RPLC method can be applied for rapid evaluation of sweeteners' content, quality and safety control. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:184 / 192
页数:9
相关论文
共 50 条
  • [1] Determination of eight artificial sweeteners and common Stevia rebaudiana glycosides in non-alcoholic and alcoholic beverages by reversed-phase liquid chromatography coupled with tandem mass spectrometry
    Paweł Kubica
    Jacek Namieśnik
    Andrzej Wasik
    [J]. Analytical and Bioanalytical Chemistry, 2015, 407 : 1505 - 1512
  • [2] Determination of eight artificial sweeteners and common Stevia rebaudiana glycosides in non-alcoholic and alcoholic beverages by reversed-phase liquid chromatography coupled with tandem mass spectrometry
    Kubica, Pawel
    Namiesnik, Jacek
    Wasik, Andrzej
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (05) : 1505 - 1512
  • [3] Determination of eight artificial sweeteners in wastewater by hydrophilic interaction liquid chromatography-tandem mass spectrometry
    Kokotou, Maroula G.
    Thomaidis, Nikolaos S.
    [J]. ANALYTICAL METHODS, 2013, 5 (16) : 3825 - 3833
  • [4] Discrepancies in determination of biogenic amines in beer samples by reversed phase and hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry
    Nalazek-Rudnicka, Katarzyna
    Kubica, Pawel
    Wasik, Andrzej
    [J]. MICROCHEMICAL JOURNAL, 2020, 159
  • [5] Determination of 14 sweeteners in liquid foods by hydrophilic interaction liquid chromatography-tandem mass spectrometry
    Fan Guangyu
    Feng Feng
    Zhang Feng
    Gao Fei
    Li Xiaoming
    Liang Zhengang
    [J]. CHINESE JOURNAL OF CHROMATOGRAPHY, 2018, 36 (04) : 351 - 355
  • [6] Systematic comparison of sensitivity between hydrophilic interaction liquid chromatography and reversed phase liquid chromatography coupled with mass spectrometry
    Periat, Aurelie
    Boccard, Julien
    Veuthey, Jean-Luc
    Rudaz, Serge
    Guillarme, Davy
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2013, 1312 : 49 - 57
  • [7] Artificial sweeteners in beverages by ultra performance liquid chromatography with photodiode array and liquid chromatography tandem mass spectrometry
    Lorenzo, R. A.
    Pena, M. T.
    Fernandez, P.
    Gonzalez, P.
    Carro, A. M.
    [J]. FOOD CONTROL, 2015, 47 : 43 - 52
  • [8] Determination of artificial sweeteners in beverages with green mobile phases and high temperature liquid chromatography-tandem mass spectrometry
    Ordonez, Edgar Y.
    Rodil, Rosario
    Benito Quintana, Jose
    Cela, Rafael
    [J]. FOOD CHEMISTRY, 2015, 169 : 162 - 168
  • [9] Comparison of hydrophilic interaction and reversed-phase liquid chromatography coupled with tandem mass spectrometric detection for the determination of three pharmaceuticals in human plasma
    Apostolou, Constantinos
    Kousoulos, Constantinos
    Dotsikas, Yannis
    Loukas, Yannis L.
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (12) : 1393 - 1402
  • [10] Hydrophilic interaction liquid chromatography coupled to high-resolution mass spectrometry to determine artificial sweeteners in environmental waters
    Daniela Salas
    Francesc Borrull
    Núria Fontanals
    Rosa Maria Marcé
    [J]. Analytical and Bioanalytical Chemistry, 2015, 407 : 4277 - 4285