Shared-photodetector readout to improve the sensitivity of positron emission tomography

被引:10
|
作者
Du, Junwei [1 ]
Peng, Peng [1 ]
Bai, Xiaowei [1 ]
Cherry, Simon R. [1 ]
机构
[1] Univ Calif Davis, Dept Biomed Engn, One Shields Ave, Davis, CA 95616 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2018年 / 63卷 / 20期
关键词
positron emission tomography (PET); depth-of-interaction (DOI); shared-photodetector readout; sensitivity; RESOLUTION; SCINTILLATORS; DETECTORS; DESIGN; DEPTH;
D O I
10.1088/1361-6560/aae056
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Sensitivity is an important performance characteristic of positron emission tomography (PET) systems. Improved sensitivity can be used to reduce injected dose, reduce scan time, or improve the signal-to-noise ratio and temporal resolution for dynamic studies. One way to improve the sensitivity of PET scanners is to reduce the gaps between detector modules. In this paper, a new signal processing method, named the shared-photodetector readout method, is proposed and evaluated. In this method, the signals generated in nearest neighbor photodetectors adjacent to the detector module of interest, were used to help identify the interaction location in the detector module of interest. Using this method, scintillator array-based detector modules with almost 100% packing fraction can be built, and the edge crystals can be clearly resolved, even when the crystals are small compared to the photodetector size. To evaluate this signal processing concept in one dimension, a detector block with four dual-ended readout detector modules, was designed. The detector block consisted of eight 4 x 4 arrays of SensL MicroFJ-30035 SiPMs coupled to both ends of a 14 x 56 array of 0.9 x 0.9 x 20 mm(3) LYSO elements with a pitch size of 0.96 mm and a length of 20 mm. Performance in terms of energy resolution, flood histogram, timing resolution and depth-of interaction resolution obtained using the shared-photodetector readout method were compared to those obtained using a conventional readout method. The results show that better over-all performance was achieved using the shared-photodetector readout method, especially at the edges and corners of the array.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Readout of LYSO using a new silicon photodetector for positron emission tomography
    Lerch, MLF
    Ward, R
    Simmonds, PE
    Pervertailo, VL
    Meikle, SR
    Taylor, GN
    Rosenfeld, AB
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1408 - 1412
  • [2] PETRIC - A positron emission tomography readout integrated circuit
    Pedrali-Noy, M
    Grubre, G
    Krieger, B
    Mandelli, E
    Meddeler, G
    Moses, W
    Rosso, V
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (03) : 479 - 484
  • [3] Readout of scintillator light with avalanche photodiodes for positron emission tomography
    Chen, RR
    Fremout, A
    Tavernier, S
    Bruyndonckx, P
    Clément, D
    Loude, JF
    Morel, C
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 433 (03): : 637 - 645
  • [4] Readout of scintillator light with avalanche photodiodes for positron emission tomography
    Chen, Ruru
    Fremout, A.
    Tavernier, S.
    Bruyndonckx, P.
    Clément, D.
    Loude, J.-F.
    Morel, C.
    [J]. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1999, 433 (03): : 637 - 645
  • [5] An edge-readout, multilayer detector for positron emission tomography
    Li, Xin
    Ruiz-Gonzalez, Maria
    Furenlid, Lars R.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : 2425 - 2438
  • [6] Development of a multiplexed readout with high position resolution for positron emission tomography
    Lee, Sangwon
    Choi, Yong
    Kang, Jihoon
    Jung, Jin Ho
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 850 : 42 - 47
  • [7] RECONSTRUCTION ALGORITHM FOR HIGHER SENSITIVITY POSITRON EMISSION TOMOGRAPHY
    PELC, NJ
    CHESLER, DA
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1979, 3 (04) : 572 - 572
  • [8] Overview of Positron Emission Tomography, Hybrid Positron Emission Tomography Instrumentation, and Positron Emission Tomography Quantification
    Kwee, Thomas C.
    Torigian, Drew A.
    Alavi, Abass
    [J]. JOURNAL OF THORACIC IMAGING, 2013, 28 (01) : 4 - 10
  • [9] BAF2 SCINTILLATORS WITH WIRE CHAMBER READOUT FOR POSITRON EMISSION TOMOGRAPHY
    BRUYNDONCKX, P
    DEBRUYNE, J
    ETIENNE, L
    GRUWE, M
    GUERARD, B
    TAVERNIER, S
    SHUPING, Z
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 310 (1-2): : 107 - 115
  • [10] Silicon photomultiplier signal readout and multiplexing techniques for positron emission tomography: a review
    Haewook Park
    Minseok Yi
    Jae Sung Lee
    [J]. Biomedical Engineering Letters, 2022, 12 : 263 - 283