COAST: Modelling Restenosis and Stent Based Therapies

被引:0
|
作者
Evans, D. J. W. [1 ]
Caiazzo, A. [3 ]
Falcone, J. L. [4 ]
Hegewald, J. [5 ]
Lorenz, E. [6 ]
Stahl, B. [4 ]
Wang, D. [7 ]
Bernsdorf, J. [7 ]
Chopard, B. [4 ]
Gunn, J. [1 ]
Walker, D. [2 ]
Hose, R. [1 ]
Krafczyk, M. [5 ]
Hoekstra, A. [6 ]
Lawford, P. [1 ]
机构
[1] Univ Sheffield, Med Phys Grp, Sheffield, S Yorkshire, England
[2] Univ Sheffield, Dept Comp Sci, Sheffield, S Yorkshire, England
[3] INRIA Rocquencourt, Paris, France
[4] Univ Geneva, CUI Dept, Geneva, Switzerland
[5] Tech Univ Carolo Wilhelmina Braunschweig, Inst Comp Appl Civil Engn, Braunschweig, Germany
[6] Univ Amsterdam, Computat Sci, Amsterdam, Netherlands
[7] NEC Europe Ltd, NEC Labs Europe, St Augustin, Germany
关键词
Restenosis; Stent; Complex Automata; Coupling; Multiscale; COMPLEX AUTOMATA; CORONARY-ARTERY; CELLS;
D O I
10.1007/978-3-642-04292-8_71
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
COAST (Complex Automata Simulation Technique) is a European Union FP6 funded project which has developed a methodology for multi-science, multi-scale simulation of complex systems. The resulting framework (MUSCLE: Multiscale Simulation Coupling Library and Environment is now publically available. As an exemplar, MUSCLE has been applied to the model of a complex biomedical pathology, that of in-stent restenosis, resulting in a hierarchical aggregation of coupled cellular automata and agent based models coined "complex automaton". Currently, three simple, single scale models have been coupled to simulate the pathological response of the arterial wall to stent-deployment: an agent based model of smooth muscle cell dynamics (modeling cell cycle and cell-cell interaction), a lattice Boltzmann model of blood flow (defining wall shear stress and oscillatory shear index at the vessel surface) and a finite difference drug diffusion model (defining stent-eluted drug concentrations across the vessel wall). These sub-models operate on distinct temporal scales and can be plotted on a scale separation map. This conceptual tool defines the temporal separation of the processes and the coupling template required for interaction between them PI. Coupling is implemented using smart conduits and in some situations, mapper agents, which transfer information between models with lattice based domains (blood flow, drug diffusion) to those with continuous domains (smooth muscle behaviour). Here we present preliminary output of a simple 2D model of in-stent restenosis. The present model captures the relationship between degree of stent induced injury and the smooth muscle cell hyperplastic response. The generation of realistic output correlates well with experimental data and paves the way for computer-aided design of stent-based therapies.
引用
收藏
页码:319 / +
页数:2
相关论文
共 50 条
  • [1] Mycophenolic acid-eluting stent and the ABC's of stent-based immunosuppressive therapies for the prevention of restenosis
    Carter, AJ
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2005, 66 (04) : 496 - 498
  • [2] Mathematical modelling of the restenosis process after stent implantation
    Escuer, Javier
    Martinez, Miguel A.
    McGinty, Sean
    Pena, Estefania
    [J]. JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2019, 16 (157)
  • [3] Gene-based therapies for restenosis
    Labhasetwar, V
    Chen, BR
    Muller, DWM
    Bonadio, J
    Ciftci, K
    March, K
    Levy, RJ
    [J]. ADVANCED DRUG DELIVERY REVIEWS, 1997, 24 (01) : 109 - 120
  • [4] Modelling the Effect of a Functional Endothelium on the Development of In-Stent Restenosis
    Tahir, Hannan
    Bona-Casas, Carles
    Hoekstra, Alfons G.
    [J]. PLOS ONE, 2013, 8 (06):
  • [5] Modelling the Development of In-Stent Restenosis: Preliminary Results of a Structural Model
    Amatruda, C. M.
    Hose, D. R.
    Lawford, P. V.
    Narracott, A. J.
    [J]. INTERNATIONAL CONFERENCE ON ADVANCEMENTS OF MEDICINE AND HEALTH CARE THROUGH TECHNOLOGY, 2011, 36 : 276 - 279
  • [6] Patient-specific modelling of stent overlap: Lumen gain, tissue damage and in-stent restenosis
    He, R.
    Zhao, L. G.
    Silberschmidt, V. V.
    Liu, Y.
    Vogt, F.
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2020, 109
  • [7] Treatment of long in-stent restenosis: A comparison of therapies with cutting balloon and rotablator.
    Braun, P
    Heinrich, KW
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (5A): : 17G - 17G
  • [8] In stent restenosis: bane of the stent era
    Mitra, AK
    Agrawal, DK
    [J]. JOURNAL OF CLINICAL PATHOLOGY, 2006, 59 (03) : 232 - 239
  • [9] In-Stent Restenosis
    Kim, Michael S.
    Dean, Larry S.
    [J]. CARDIOVASCULAR THERAPEUTICS, 2011, 29 (03) : 190 - 198
  • [10] Investigating the effect of drug release on in-stent restenosis: A hybrid continuum - agent-based modelling approach
    Corti, Anna
    Mcqueen, Alistair
    Migliavacca, Francesco
    Chiastra, Claudio
    Mcginty, Sean
    [J]. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2023, 241