Heat transfer and pressure drop measurements in rib-roughened rectangular ducts

被引:126
|
作者
Gao, XF [1 ]
Sundén, B [1 ]
机构
[1] Lund Inst Technol, Div Heat Transfer, S-22100 Lund, Sweden
关键词
liquid crystal thermography; heat transfer enhancement; pressure drop; rib-roughened duct;
D O I
10.1016/S0894-1777(00)00054-6
中图分类号
O414.1 [热力学];
学科分类号
摘要
In the present study, the thermal and hydraulic performance of three rib-roughened rectangular ducts is investigated. The aspect ratio of the ducts was 1 to 8, and the ribs were arranged staggered on the two wide walls. Three rib configurations were tested: parallel ribs and V-shaped ribs pointing upstream or downstream of the main flow direction. For all cases, the rib height-to-hydraulic diameter ratio was 0.06, with an attack angle of 60 degrees and a pitch-to-height ratio of 10. The Reynolds number range was from 1000 to 6000. Liquid crystal thermography was employed in the heat transfer experiment to demonstrate detailed temperature distribution between a pair of ribs on the ribbed surfaces. The secondary flows caused by the inclined ribs create a significant spanwise variation of the heat transfer coefficients on the rib-roughened wall with high heat transfer coefficient at one end of the rib and low value at the other. In the streamwise direction between two consecutive ribs, the temperature distribution shows a sawtooth fashion because of flow reattachment. Based on the local heat transfer coefficients, the average Nusselt numbers were estimated as weighted mean values. Isothermal pressure drop data were taken and presented as Fanning friction factors. The ducts are compared to each other by considering both heat transfer and friction factor performance. (C) 2001 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:25 / 34
页数:10
相关论文
共 50 条
  • [1] Enhancement of convective heat transfer in rib-roughened rectangular ducts
    Sundén, B
    [J]. JOURNAL OF ENHANCED HEAT TRANSFER, 1999, 6 (2-4) : 89 - 103
  • [2] Heat Transfer and Pressure Drop Measurements of Rotating Rib-Roughened Parallelogram Channel
    Chang, S. W.
    Liou, T. -M.
    Lee, T. -H.
    [J]. JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2012, 26 (01) : 98 - 107
  • [3] Rib heat transfer coefficient measurements in a rib-roughened square passage
    Korotky, GJ
    Taslim, ME
    [J]. JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 1998, 120 (02): : 376 - 385
  • [4] Heat transfer coefficient and friction factor correlations for the transitional flow regime in rib-roughened rectangular ducts
    Karwa, R
    Solanki, SC
    Saini, JS
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1999, 42 (09) : 1597 - 1615
  • [5] Effect of Entrance Geometry on Heat Transfer in a Rib-Roughened Rectangular Channel
    Satta, Francesca
    Tanda, Giovanni
    Venturino, Giulio
    [J]. HEAT TRANSFER ENGINEERING, 2022, 43 (07) : 623 - 637
  • [6] Experimental study of flow and heat transfer in rib-roughened rectangular channels
    Olsson, CO
    Sunden, B
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 1998, 16 (04) : 349 - 365
  • [7] Effects of rib arrangements on pressure drop and heat transfer in a rib-roughened channel with a sharp 180 deg turn
    Mochizuki, S
    Murata, A
    Fukunaga, M
    [J]. JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 1997, 119 (03): : 610 - 616
  • [8] FRICTION FACTOR FOR FLOW IN RECTANGULAR DUCTS WITH ONE SIDE RIB-ROUGHENED
    YOUN, B
    YUEN, C
    MLLS, AF
    [J]. JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 1994, 116 (03): : 488 - 493
  • [9] HEAT/MASS TRANSFER AND PRESSURE-DROP IN A TRIANGULAR-RIB-ROUGHENED RECTANGULAR CHANNEL
    LING, CM
    JIN, YY
    CHEN, ZQ
    [J]. INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 1994, 15 (06) : 486 - 490
  • [10] HEAT TRANSFER AND PRESSURE DROP MEASUREMENTS IN A RIB ROUGHENED LEADING EDGE COOLING CHANNEL
    Domaschke, Norbert
    von Wolfersdorf, Jens
    Semmler, Klaus
    [J]. PROCEEDINGS OF THE ASME TURBO EXPO 2009, VOL 3, PTS A AND B, 2009, : 337 - 348