CAD/CAM single-retainer monolithic zirconia ceramic resin-bonded fixed partial dentures bonded with two different resin cements: Up to 40 months clinical results of a randomized-controlled pilot study

被引:5
|
作者
Bilir, Halenur [1 ]
Yuzbasioglu, Emir [2 ]
Sayar, Gulsilay [3 ]
Kilinc, Delal Dara
Bag, Harika Gozde Gozukara [4 ]
Ozcan, Mutlu [5 ]
机构
[1] Istanbul Medipol Univ, Sch Dent, Dept Prosthodont, TEM Avrupa Otoyolu Cikisi 1 Bagcilar, Istanbul, Turkey
[2] Bahcesehir Univ, Sch Dent Med, Dept Prosthodont, Istanbul, Turkey
[3] Bahcesehir Univ, Sch Dent Med, Dept Orthodont, Istanbul, Turkey
[4] Inonu Univ, Dept Biostat, Fac Med, Malatya, Turkey
[5] Univ Zurich, Dent Mat Unit, Ctr Dent & Oral Med, Clin Fixed & Removable Prosthodont & Dent Mat Sci, Zurich, Switzerland
关键词
CAD; CAM; ceramics; dental materials; digital dentistry; prosthodontics; DENTAL PROSTHESES; COMPLICATION RATES; OBSERVATION PERIOD; SAMPLE-SIZE; SURVIVAL; RESTORATIONS; AGENESIS; BRIDGES; TRIAL;
D O I
10.1111/jerd.12945
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose This pilot study was part of a larger study planned for the future which aimed to compare the clinical success of two different resin cements used in the cementation of CAD/CAM single-retainer monolithic zirconia ceramic resin-bonded fixed dentures (RBFPDs). Methods Twenty-four RBFPDs were fabricated with monolithic zirconia (Katana (TM) Zirconia HT, Kuraray Noritake Dental Inc, Tokyo, Japan). Panavia F2.0 (PF2.0; n = 12) and Panavia V5 (PV5; n = 12) were used for cementation. The survival period was defined as the time when the restoration was placed in the mouth and lasted until an irreparable damage occurred. The repairable failures were identified as relative and irreparable failures were identified as absolute failure. The survival rate of the RBFPDs was determined by the Kaplan-Meier estimator. Statistical significance was set at p < 0.05. Results The mean observation times of the PF2.0 group and the PV5 group were 40.45 +/- 6.15 months and 40.18 +/- 6.41 months, respectively. Four failures occurred in the PF2.0 group. No failure was observed in the PV5 group. The curves of survival rate (PF2.0 = 80%, PV5 = 100%) showed no statistically significant difference (p = 0.031), although success rate (PF2.0 = 66.7%, PV5 = 100%) showed statistically significant difference (p = 0.317). Conclusion Up to 40 months mean follow-up period, performance of RBFPDs bonded with PV5 was better than with PF2.0. Clinical Significance For clinicians, it is a matter of hesitation to apply single-retainer RBFPDs. This study contains results of 40 months (minimum 32, maximum 50.47 months) clinical follow-ups of single-retainer RBFPDs. These results will enlighten clinicians about the clinical success of the resin cement type for single-retainer monolithic zirconia ceramic RBFPDs.
引用
收藏
页码:1122 / 1131
页数:10
相关论文
共 17 条
  • [1] Clinical long-term survival of two-retainer and single-retainer all-ceramic resin-bonded fixed partial dentures
    Kern, M
    [J]. QUINTESSENCE INTERNATIONAL, 2005, 36 (02): : 141 - 147
  • [2] Randomized clinical trial on single retainer all-ceramic resin-bonded fixed partial dentures: Influence of the bonding system after up to 55 months
    Sasse, Martin
    Eschbach, Stephanie
    Kern, Matthias
    [J]. JOURNAL OF DENTISTRY, 2012, 40 (09) : 783 - 786
  • [3] CAD/CAM Single Retainer Zirconia-Ceramic Resin-Bonded Fixed Dental Prostheses: Clinical Outcome after 5 Years
    Sasse, M.
    Kern, M.
    [J]. INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2013, 16 (02) : 109 - 118
  • [4] Three-dimensional finite element analysis of stress distribution of two-retainer and single-retainer all-ceramic resin-bonded fixed partial dentures
    Toman, Muhittin
    Toksavul, Suna
    Sabanci, Sercan
    Kiran, Begum
    Dikici, Serkan
    Sarikanat, Mehmet
    Oflaz, Hakan
    [J]. QUINTESSENCE INTERNATIONAL, 2015, 46 (08): : 691 - 696
  • [5] Zirconia Ceramic Single-Retainer Resin-Bonded Fixed Dental Prostheses (RBFDPs) After 4 Years of Clinical Service: A Retrospective Clinical and Volumetric Study
    Sailer, Irene
    Haemmerle, Christoph Hans Franz
    [J]. INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2014, 34 (03) : 333 - 343
  • [6] Successful use of a single-retainer all-ceramic resin-bonded fixed partial denture for replacement of a maxillary canine: A clinical report
    Foitzik, Magdalena
    Lennon, Aine M.
    Attin, Thomas
    [J]. QUINTESSENCE INTERNATIONAL, 2007, 38 (03): : 241 - 246
  • [7] Clinical evaluation of zirconia cantilevered single-retainer resin-bonded fixed dental prostheses replacing missing canines and posterior teeth
    Yazigi, Christine
    Kern, Matthias
    [J]. JOURNAL OF DENTISTRY, 2022, 116
  • [8] Influence of the amount of tooth surface preparation on the shear bond strength of zirconia cantilever single-retainer resin-bonded fixed partial denture
    Sillam, Charles-Ellie
    Cetik, Sibel
    Thai Hoang Ha
    Atash, Ramin
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2018, 10 (04): : 286 - 290
  • [9] Clinical Performance of Posterior Inlay-Retained and Wing-Retained Monolithic Zirconia Resin-Bonded Fixed Partial Dentures: Stage One Results of a Randomized Controlled Trial
    Boemicke, Wolfgang
    Rathmann, Friederike
    Pilz, Maximilian
    Bermejo, Justo Lorenzo
    Waldecker, Moritz
    Ohlmann, Brigitte
    Rammelsberg, Peter
    Zenthoefer, Andreas
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2021, 30 (05): : 384 - 393
  • [10] Retrospective Clinical Study of Single-Retainer Cantilever Anterior and Posterior Glass-Ceramic Resin-Bonded Fixed Dental Prostheses at a Mean Follow-up of 6 Years
    Sailer, Irena
    Bonani, Tom
    Brodbeck, Urs
    Haemmerle, Christoph Hans Franz
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2013, 26 (05) : 443 - 450