A stationary pseudophase semi-permanent coating for open-tubular capillary liquid chromatography and electrochromatography

被引:6
|
作者
Ahmed, Mohamed Adel [1 ]
Felisilda, Bren Mark [1 ]
Wuethrich, Alain [2 ]
Quirino, Joselito P. [1 ]
机构
[1] Univ Tasmania, Australian Ctr Res Separat Sci ACROSS, Sch Nat Sci Chem, Hobart, Tas 7001, Australia
[2] Univ Queensland, Australian Inst Bioengn & Biotechnol AIBN, Brisbane, Qld, Australia
基金
澳大利亚研究理事会;
关键词
Capillary electrochromatography; Liquid chromatography; Open-tubular separations; Semi-permanent coating; Small molecules; Stationary pseudophase; POROUS SILICA LAYERS; ELECTROKINETIC CHROMATOGRAPHY; SURFACTANT COATINGS; SEPARATION; PHASE; ELECTROPHORESIS; PERFORMANCE; COLUMNS; WATER;
D O I
10.1016/j.chroma.2021.462553
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We describe the chromatographic and electrochromatographic separation of small neutral and charged analytes using a fused silica capillary with a stationary pseudophase semi-permanent coating of dido-decyldimethyl ammonium bromide (DDAB) aggregates. The coating was prepared by flushing the capil-lary with a DDAB solution that was rinsed out with the mobile phase. Our studies (i.e., electroosmotic flow measurements by capillary electrophoresis, chromatographic retention of a neutral probe and atomic force microscopy) suggested the formation of DDAB patchy admicelle, complete admicelle, or larger ag-gregates at the solid surface -liquid interface inside the capillary, depending on the concentration of DDAB used in coating the capillary. The analytical figures of merit for open tubular liquid chromatogra-phy (OT-LC, pressure driven) and open tubular capillary electrochromatography (OT-CEC, voltage driven) using a capillary coated with 0.5 mM DDAB and mobile phase/background solution of 25 mM borate buffer at pH 9.5 with 10% MeOH were the following: LOD = 3.0-5.0 mu g/mL (OT-LC) and 2.5-5.0 mu g/mL (OT-CEC); linearity R2 0.99 (peak area (OT-LC) and corrected peak area (OT-CEC)), intraday and inter-day repeatability%RSD < 5% ( n = 12) for retention/migration time, peak area (OT-LC) and corrected peak area (OT-CEC). The reversed-phase and anion-exchange property of the stationary pseudophase was stud-ied by the addition of organic solvents and sodium chloride to the mobile phase, respectively. We also demonstrate the increase in the ks of the tested analytes by implementing successive multiple ionic layer (SMIL) coating strategies with DDAB in combination with a cationic and/or anionic polyelectrolyte. The use of a stationary pseudophase coating is potentially an easy alternative way to conduct open-tubular liquid chromatography and electrochromatography. Crown Copyright (c) 2021 Published by Elsevier B.V. All rights reserved.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] A stationary pseudophase semi-permanent coating for open-tubular capillary liquid chromatography and electrochromatography
    Ahmed, Mohamed Adel
    Felisilda, Bren Mark
    Wuethrich, Alain
    Quirino, Joselito P.
    Quirino, Joselito P. (jquirino@utas.edu.au), 1600, Elsevier B.V. (1657):
  • [2] A novel open-tubular capillary electrochromatography with magnetic nanoparticle coating as stationary phase
    Zhu, Yaxian
    Zhou, Chaoran
    Qin, Sasa
    Ren, Zhiyu
    Zhang, Lingyi
    Fu, Honggang
    Zhang, Weibing
    ELECTROPHORESIS, 2012, 33 (02) : 340 - 347
  • [3] Metallomesogenic stationary phase for open-tubular capillary electrochromatography
    Chen, JL
    ELECTROPHORESIS, 2006, 27 (04) : 729 - 735
  • [4] Application of graphene as the stationary phase for open-tubular capillary electrochromatography
    Liu, Xi
    Liu, Xiaoling
    Li, Min
    Guo, Liping
    Yang, Li
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1277 : 93 - 97
  • [5] Open-tubular capillary electrochromatography using a polymeric surfactant coating
    Kamande, MW
    Kapnissi, CP
    Zhu, XF
    Akbay, C
    Warner, IM
    ELECTROPHORESIS, 2003, 24 (06) : 945 - 951
  • [6] Open-tubular capillary electrochromatography (Review)
    Jinno, K
    Sawada, H
    BUNSEKI KAGAKU, 1999, 48 (11) : 957 - 971
  • [7] An immobilized graphene oxide stationary phase for open-tubular capillary electrochromatography
    Wang, Chun
    de Rooy, Sergio
    Lu, Cheng-Fei
    Fernand, Vivian
    Moore, Leonard, Jr.
    Berton, Paula
    Warner, Isiah M.
    ELECTROPHORESIS, 2013, 34 (08) : 1197 - 1202
  • [8] Polymer-brush stationary phases for open-tubular capillary electrochromatography
    Miller, MD
    Baker, GL
    Bruening, ML
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1044 (1-2) : 323 - 330
  • [9] Recent highlights in stationary phase design for open-tubular capillary electrochromatography
    Guihen, E
    Glennon, JD
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1044 (1-2) : 67 - 81
  • [10] Chiral separation using cyclodextrins as mobile phase additives in open-tubular liquid chromatography with a pseudophase coating
    Yu, Raymond B.
    Quirino, Joselito P.
    JOURNAL OF SEPARATION SCIENCE, 2022, 45 (06) : 1195 - 1201