The effect of stimulus number on the recognition accuracy and information transfer rate of SSVEP-BCI in augmented reality

被引:21
|
作者
Zhang, Rui [1 ]
Xu, Zongxin [1 ]
Zhang, Lipeng [1 ]
Cao, Lijun [1 ]
Hu, Yuxia [1 ]
Lu, Beihan [2 ]
Shi, Li [3 ]
Yao, Dezhong [1 ,4 ,5 ]
Zhao, Xincan [6 ]
机构
[1] Zhengzhou Univ, Sch Elect Engn, Henan Key Lab Brain Sci & Brain Comp Interface Te, Zhengzhou 450001, Peoples R China
[2] Zhengzhou Univ, Int Coll, Zhengzhou 450001, Peoples R China
[3] Tsinghua Univ, Dept Automat, Beijing 100084, Peoples R China
[4] Univ Elect Sci & Technol China, Chengdu Brain Sci Inst, MOE Key Lab Neuroinformat, Clin Hosp, Chengdu 611731, Peoples R China
[5] Univ Elect Sci & Technol China, Ctr Informat Med, Sch Life Sci & Technol, Chengdu 611731, Peoples R China
[6] Zhengzhou Univ, Sch Informat Engn, Zhengzhou 450001, Peoples R China
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
steady-state visually evoked potential (SSVEP); augmented reality (AR); computer screen (CS); information transfer rate (ITR); brain-computer interface (BCI); BRAIN-COMPUTER-INTERFACE; FREQUENCY; VISION; FIELD;
D O I
10.1088/1741-2552/ac6ae5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. The biggest advantage of steady-state visual evoked potential (SSVEP)-based brain-computer interface (BCI) lies in its large command set and high information transfer rate (ITR). Almost all current SSVEP-BCIs use a computer screen (CS) to present flickering visual stimuli, which limits its flexible use in actual scenes. Augmented reality (AR) technology provides the ability to superimpose visual stimuli on the real world, and it considerably expands the application scenarios of SSVEP-BCI. However, whether the advantages of SSVEP-BCI can be maintained when moving the visual stimuli to AR glasses is not known. This study investigated the effects of the stimulus number for SSVEP-BCI in an AR context. Approach. We designed SSVEP flickering stimulation interfaces with four different numbers of stimulus targets and put them in AR glasses and a CS to display. Three common recognition algorithms were used to analyze the influence of the stimulus number and stimulation time on the recognition accuracy and ITR of AR-SSVEP and CS-SSVEP. Main results. The amplitude spectrum and signal-to-noise ratio of AR-SSVEP were not significantly different from CS-SSVEP at the fundamental frequency but were significantly lower than CS-SSVEP at the second harmonic. SSVEP recognition accuracy decreased as the stimulus number increased in AR-SSVEP but not in CS-SSVEP. When the stimulus number increased, the maximum ITR of CS-SSVEP also increased, but not for AR-SSVEP. When the stimulus number was 25, the maximum ITR (142.05 bits min(-1)) was reached at 400 ms. The importance of stimulation time in SSVEP was confirmed. When the stimulation time became longer, the recognition accuracy of both AR-SSVEP and CS-SSVEP increased. The peak value was reached at 3 s. The ITR increased first and then slowly decreased after reaching the peak value. Significance. Our study indicates that the conclusions based on CS-SSVEP cannot be simply applied to AR-SSVEP, and it is not advisable to set too many stimulus targets in the AR display device.
引用
收藏
页数:12
相关论文
共 15 条
  • [1] Visual stimulus color effect on SSVEP-BCI in augmented reality
    Du, Yulin
    Zhao, Xincan
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2022, 78
  • [2] An SSVEP-BCI in Augmented Reality
    Liu, Pengxiao
    Ke, Yufeng
    Du, Jiale
    Liu, Wentao
    Kong, Linghan
    Wang, Ningci
    An, Xingwei
    Ming, Dong
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 5548 - 5551
  • [3] SSVEP-BCI in augmented reality in realistic environment
    Chaiyarit, Bhuwit
    Pan-Ngum, Setha
    Israsena, Pasin
    Suwannarat, Arpa
    Hemakom, Apit
    2024 21ST INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING/ELECTRONICS, COMPUTER, TELECOMMUNICATIONS AND INFORMATION TECHNOLOGY, ECTI-CON 2024, 2024,
  • [4] Study on Robot Grasping System of SSVEP-BCI Based on Augmented Reality Stimulus
    Zhang, Shangen
    Chen, Yuanfang
    Zhang, Lijian
    Gao, Xiaorong
    Chen, Xiaogang
    TSINGHUA SCIENCE AND TECHNOLOGY, 2023, 28 (02): : 322 - 329
  • [5] Humanoid Robot Walking in Maze Controlled by SSVEP-BCI Based on Augmented Reality Stimulus
    Zhang, Shangen
    Gao, Xiaorong
    Chen, Xiaogang
    FRONTIERS IN HUMAN NEUROSCIENCE, 2022, 16
  • [6] A portable SSVEP-BCI system for rehabilitation exoskeleton in augmented reality environment
    Wang, Fei
    Wen, Yongzhao
    Bi, Jinying
    Li, Hao
    Sun, Jintao
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2023, 83
  • [7] Frequency Recognition for SSVEP-BCI Using Reference Signals With Dominant Stimulus Frequency
    Islam, Md. Rabiul
    Tanaka, Toshihisa
    Molla, Md. Khademul Islam
    Akter, Most. Sheuli
    2015 ASIA-PACIFIC SIGNAL AND INFORMATION PROCESSING ASSOCIATION ANNUAL SUMMIT AND CONFERENCE (APSIPA), 2015, : 971 - 974
  • [8] An online SSVEP-BCI system in an optical see-through augmented reality environment
    Ke, Yufeng
    Liu, Pengxiao
    An, Xingwei
    Song, Xizi
    Ming, Dong
    JOURNAL OF NEURAL ENGINEERING, 2020, 17 (01)
  • [9] Augmented Reality Interface for Smart Home Control using SSVEP-BCI and Eye Gaze
    Putze, Felix
    Weiss, Dennis
    Vortmann, Lisa-Marie
    Schultz, Tanja
    2019 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN AND CYBERNETICS (SMC), 2019, : 2812 - 2817
  • [10] Optimizing Stimulus Frequency Ranges for Building a High-Rate High Frequency SSVEP-BCI
    Chen, Xiaogang
    Liu, Bingchuan
    Wang, Yijun
    Cui, Hongyan
    Dong, Jianwei
    Ma, Ruijuan
    Li, Ning
    Gao, Xiaorong
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2023, 31 : 1277 - 1286