Migration of porous press-fit cups in hip revision arthroplasty - A radiostereometric 2-year follow-up study of 60 hips

被引:20
|
作者
Nivbrant, B
Karrholm, J
Onsten, I
Carlsson, A
Snorrason, F
机构
[1] Departments of Orthopedics, Northern University Hospital, Umeå
[2] Departments of Orthopedics, Sahlgrenska Hospital, Gothenburg
[3] Departments of Orthopedics, Malmö General Hospital, Malmö
[4] Departments of Orthopedics, Buskerud Hospital, Drammen
[5] Department of Orthopedics, Northern University Hospital
来源
JOURNAL OF ARTHROPLASTY | 1996年 / 11卷 / 04期
关键词
hip arthroplasty; acetabulum; uncemented; bone-graft; micromotion;
D O I
10.1016/S0883-5403(96)80027-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The migration of 60 press-fit cups fixed with screws was evaluated by radiostereometric analysis for 2 years in 57 patients revised because of aseptic loosening. The mean proximal migration of the cup center increased continuously up to 0.36 mm (range, 0.0-1.6 mm), whereas the migration in the other directions reached a level at 0.3 to 0.4 mm after 6 months. Mean rotations of less than 1 degrees were recorded. Factors influencing motions were cup size, use of bone-grafts, and position of the cup center in the vertical and horizontal directions. Compared with previous stereoradiographic studies of cemented revisions, the migration of the press-fit cup was smaller, however, still higher than previously reported for uncemented cups of the same design used in primary surgery.
引用
收藏
页码:390 / 396
页数:7
相关论文
共 50 条
  • [1] Migration and wear of hydroxyapatite-coated press-fit cups in revision hip arthroplasty -: A radiostereometric study
    Nivbrant, B
    Kärrholm, J
    [J]. JOURNAL OF ARTHROPLASTY, 1997, 12 (08): : 904 - 912
  • [2] Uncemented press-fit total hip arthroplasty using the identifit custom-molding technique - A prospective minimum 2-year follow-up study
    Robinson, RP
    Clark, JE
    [J]. JOURNAL OF ARTHROPLASTY, 1996, 11 (03): : 247 - 254
  • [3] Press-Fit Dual-Pivot Total Knee Arthroplasty: Early Results With a Minimum 2-Year Follow-Up
    Meding, John B.
    Meding, Lindsey K.
    Meneghini, R. Michael
    Williams, Timothy J.
    [J]. JOURNAL OF ARTHROPLASTY, 2022, 37 (06): : S238 - S244
  • [4] A cementless, elastic press-fit socket with and without screws A 2-year randomized controlled radiostereometric analysis of 37 hips
    Pakvis, Dean
    Luites, Joan
    van Hellemondt, Gijs
    Spruit, Maarten
    [J]. ACTA ORTHOPAEDICA, 2012, 83 (05) : 481 - 487
  • [5] Porous-coated cups fixed with screws -: A 12-year clinical and radiostereometric follow-up study of 50 hips
    Rohrl, Stephan M.
    Nivbrant, Bo
    Snorrason, Finnur
    Karrholm, Johan
    Nilsson, Kjell G.
    [J]. ACTA ORTHOPAEDICA, 2006, 77 (03) : 393 - 401
  • [6] Periacetabular bone densitometry after total hip arthroplasty with highly porous titanium cups: a 2-year follow-up prospective study
    Massari, Leo
    Bistolfi, Alessandro
    Grillo, Pier Paolo
    Borre, Alda
    Gigliofiorito, Gaetano
    Pari, Carlotta
    Francescotto, Andrea
    Tosco, Piermario
    Deledda, Davide
    Ravera, Laura
    Causero, Araldo
    [J]. HIP INTERNATIONAL, 2017, 27 (06) : 551 - 557
  • [7] Revision of Failed Total Hip Arthroplasty Acetabular Cups to Porous Tantalum Components A 5-Year Follow-Up Study
    Fernandez-Fairen, Mariano
    Murcia, Antonio
    Blanco, Agustin
    Merono, Antonio
    Murcia, Antonio, Jr.
    Ballester, Jorge
    [J]. JOURNAL OF ARTHROPLASTY, 2010, 25 (06): : 865 - 872
  • [8] Monobloc press-fit cups with large-diameter bearings are safe in revision total hip arthroplasty
    Synnott, Paul-Andre
    Sivaloganathan, Sivan
    Kiss, Marc-Olivier
    Binette, Benoit
    Morcos, Mina W.
    Vendittoli, Pascal-Andre
    [J]. ORTHOPEDIC REVIEWS, 2022, 14 (04)
  • [9] Two-year migration results of the ReCap hip resurfacing system—a radiostereometric follow-up study of 23 hips
    Thomas Baad-Hansen
    Stig Storgaard Jakobsen
    Kjeld Soballe
    [J]. International Orthopaedics, 2011, 35 : 497 - 502
  • [10] Two-year migration results of the ReCap hip resurfacing system-a radiostereometric follow-up study of 23 hips
    Baad-Hansen, Thomas
    Jakobsen, Stig Storgaard
    Soballe, Kjeld
    [J]. INTERNATIONAL ORTHOPAEDICS, 2011, 35 (04) : 497 - 502