Modal analysis of power systems with doubly fed induction generators

被引:0
|
作者
Elkington, K. [1 ]
Knazkins, V. [1 ]
Ghandhari, M. [1 ]
机构
[1] Royal Inst Technol KTH, Stockholm, Sweden
关键词
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This article is concerned with the impact of large scale wind farms utilising doubly fed induction generators on the stability of a conventional power system. Inspection of the eigenstructure of the system provides a foundation for assessment of the impact, which is then quantified by means of detailed numerical simulations. Simplified state-space models are used to describe the dynamics of generators in a very simple system, whose network is described by algebraic relations. A third order model is derived for a doubly fed induction generator. Mathematical models are used to identify the behavioural patterns of the system when it is subject to disturbances. Eigenvalue analysis reveals certain interesting properties of the system when it is subject to small disturbances. Numerical simulations show that the addition to a power system of doubly fed induction generators, such as those found in wind farms, improves the response of the system to small disturbances, but can have an adverse impact after larger disturbances.
引用
收藏
页码:140 / +
页数:2
相关论文
共 50 条
  • [1] Performance analysis of doubly fed induction generators operating in weak power systems
    Tourou, Pavlos
    Schael, Michael
    Sourkounis, Constantinos
    [J]. PROCEEDINGS OF THE 18TH MEDITERRANEAN ELECTROTECHNICAL CONFERENCE MELECON 2016, 2016,
  • [2] Modal analysis of grid-connected doubly fed induction generators
    Mei, Francoise
    Pal, Bikash
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2007, 22 (03) : 728 - 736
  • [3] On the rotor angle stability of power systems with Doubly Fed Induction Generators
    Elkington, Katherine
    Knazkins, Valerijs
    Ghandhari, Mehrdad
    [J]. 2007 IEEE LAUSANNE POWERTECH, VOLS 1-5, 2007, : 213 - 218
  • [4] Harmonic analysis of doubly fed induction generators
    Lindholm, M
    Rasmussen, TW
    [J]. PEDS 2003 : FIFTH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND DRIVE SYSTEMS, VOLS 1 AND 2, PROCEEDINGS, 2003, : 837 - 841
  • [5] Dynamic Aggregation of Doubly-Fed Induction Generators (DFIGs) for Stability Analysis of Wind Power Systems
    Li, Shenghu
    Liu, Zhengkai
    Jia, Yudong
    [J]. 2011 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2011,
  • [6] Modeling of doubly fed induction generators for distribution system power flow analysis
    Dadhania, A.
    Venkatesh, B.
    Nassif, A. B.
    Sood, V. K.
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2013, 53 : 576 - 583
  • [7] H∞ robust control for wind power systems based on doubly fed induction generators
    Fan, Pu-Cheng
    Wang, Chang-Song
    Wang, Zhi-Yu
    Yang, Jian-Cheng
    [J]. Beijing Keji Daxue Xuebao/Journal of University of Science and Technology Beijing, 2011, 33 (08): : 1018 - 1023
  • [8] Impact of FACTS controllers on the stability of power systems connected with doubly fed induction generators
    Kumar, N. Senthil
    Gokulakrishnan, J.
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2011, 33 (05) : 1172 - 1184
  • [9] Analysis on the operation of crowbar in doubly fed induction generators
    Onishi, Koji
    Li, Yingxiao
    Koiwa, Kenta
    Liu, Fang
    Zanma, Tadanao
    Liu, Kang-Zhi
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2023, 215
  • [10] Enhanced Direct Power Control of Doubly Fed Induction Generators
    Rueckert, Bastian
    Hofmann, Wilfried
    [J]. PROCEEDINGS OF 14TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (EPE-PEMC 2010), 2010,