New design total knee arthroplasty shows medial pivoting movement under weight-bearing conditions

被引:17
|
作者
Bragonzoni, Laura [2 ]
Muccioli, Giulio Maria Marcheggiani [1 ,2 ]
Bontempi, Marco [2 ]
di Sarsina, Tommaso Roberti [1 ]
Cardinale, Umberto [2 ]
Alesi, Domenico [1 ]
Iacono, Francesco [3 ]
Neri, Maria Pia [1 ]
Zaffagnini, Stefano [1 ]
机构
[1] Ist Ortoped Rizzoli, IRCCS, Orthopaed & Traumatol Clin 2, Lab Biomeccan, Via Barbiano 1-10, I-40136 Bologna, Italy
[2] Univ Bologna, Bologna, Italy
[3] Humanitas Clin Inst, Prosthet Surg & Articular Biol Reconstruct, Milan, Italy
关键词
Dynamic radiostereometric analysis; Total knee arthroplasty; In vivo knee kinematics; IN-VIVO KINEMATICS; MOBILE-BEARING; LIVING KNEE; FLEXION; TKA; REPLACEMENT; STABILITY; GEOMETRY;
D O I
10.1007/s00167-018-5243-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeTo assess, using model-based dynamic radiostereometric analysis (RSA), the biomechanical behaviour of a new design posterior-stabilized (PS) fixed-bearing (FB) total knee arthroplasty (TKA) in vivo while patients performing two common motor tasks. The hypothesis was that model-based dynamic RSA is able to detect different behaviour of the implant under weight-bearing and non-weight-bearing conditions.MethodsA cohort of 15 non-consecutive patients was evaluated by dynamic RSA 9months after TKA implantation. The mean age of patients was 73.4 (65-72) years. The kinematic evaluations were performed using an RSA device (BI-STAND DRX 2) developed in our Institute. The patients were asked to perform two active motor tasks: sit-to-stand in weight-bearing condition; range of motion (ROM) while sitting on the chair. The motion parameters were evaluated using the Grood and Suntay decomposition and the low-point kinematics methods.ResultsThe dynamic RSA evaluation showed a significant difference (p<0.05) between the biomechanical behaviour of the prosthesis during the two motor tasks. When subjected to the patient weight (in the sit-to-stand) the low point of the medial compartment had a shorter motion (5.70.2mm) than the lateral (11.00.2mm). This realizes a medial pivot motion as in the normal knee. In the ROM task, where the patient had no weight on the prosthesis, this difference was not present: the medial compartment had a displacement of 12.7 +/- 0.2mm, while the lateral had 17.3 +/- 0.2mm.Conclusions Model-based RSA proved to be an effective tool for the evaluation of TKA biomechanics. In particular, it was able to determine that the fixed-bearing posterior-stabilized TKA design evaluated in this study showed a medial pivoting movement under weight-bearing conditions that was not present when load was not applied. Under loading conditions what drives the pattern of movement is the prosthetic design itself. By the systematic use of this study protocol future comparisons among different implants could be performed, thus contributing significantly to the improvement of TKA design.Level of evidence IV.
引用
收藏
页码:1049 / 1056
页数:8
相关论文
共 50 条
  • [1] New design total knee arthroplasty shows medial pivoting movement under weight-bearing conditions
    Laura Bragonzoni
    Giulio Maria Marcheggiani Muccioli
    Marco Bontempi
    Tommaso Roberti di Sarsina
    Umberto Cardinale
    Domenico Alesi
    Francesco Iacono
    Maria Pia Neri
    Stefano Zaffagnini
    Knee Surgery, Sports Traumatology, Arthroscopy, 2019, 27 : 1049 - 1056
  • [2] Range of motion after total knee arthroplasty - The effect of implant design and weight-bearing conditions
    Dennis, DA
    Komistek, RD
    Stiehl, JB
    Walker, SA
    Dennis, KN
    JOURNAL OF ARTHROPLASTY, 1998, 13 (07): : 748 - 752
  • [3] In vivo weight-bearing kinematics with medial rotation knee arthroplasty
    Moonot, Pradeep
    Shang, Mu
    Railton, Gilbert T.
    Field, Richard E.
    Banks, Scott A.
    KNEE, 2010, 17 (01): : 33 - 37
  • [4] In vivo kinematics of mobile-bearing total knee arthroplasty during deep knee bending under weight-bearing conditions
    Kazuma Futai
    Tetsuya Tomita
    Takaharu Yamazaki
    Masashi Tamaki
    Hideki Yoshikawa
    Kazuomi Sugamoto
    Knee Surgery, Sports Traumatology, Arthroscopy, 2011, 19 : 914 - 920
  • [5] THE EFFECT OF EARLY WEIGHT-BEARING IN TOTAL KNEE ARTHROPLASTY
    GRACE, DL
    CRACCHIOLO, A
    DOREY, FJ
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1986, (207) : 178 - 185
  • [6] In vivo kinematics of mobile-bearing total knee arthroplasty during deep knee bending under weight-bearing conditions
    Futai, Kazuma
    Tomita, Tetsuya
    Yamazaki, Takaharu
    Tamaki, Masashi
    Yoshikawa, Hideki
    Sugamoto, Kazuomi
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (06) : 914 - 920
  • [7] In vivo kinematic comparison of medial pivot total knee arthroplasty in weight-bearing and non-weight-bearing deep knee bending
    Kage, Tomofumi
    Inui, Hiroshi
    Tomita, Tetsuya
    Yamazaki, Takaharu
    Taketomi, Shuji
    Yamagami, Ryota
    Kono, Kenichi
    Kawaguchi, Kohei
    Murakami, Ryo
    Arakawa, Takahiro
    Tanaka, Sakae
    CLINICAL BIOMECHANICS, 2022, 99
  • [8] In Vivo Postoperative Motion of Fixed and Mobile Medial Pivot Knees Under Weight-Bearing Conditions after Cruciate-Sacrificing Total Knee Arthroplasty
    Yoshioka, Toru
    Okimoto, Nobukazu
    Sawa, Mikiya
    Asano, Kei
    Obayashi, Kenji
    Kawasaki, Makoto
    Majima, Tokifumi
    JOURNAL OF NIPPON MEDICAL SCHOOL, 2023, 90 (01) : 103 - 110
  • [9] Fixed versus mobile weight-bearing prosthesis in total knee arthroplasty
    Hamidreza Shemshaki
    Mohammad Dehghani
    Mohammad Amin Eshaghi
    Mahboobe Fereidan Esfahani
    Knee Surgery, Sports Traumatology, Arthroscopy, 2012, 20 : 2519 - 2527
  • [10] Fixed versus mobile weight-bearing prosthesis in total knee arthroplasty
    Shemshaki, Hamidreza
    Dehghani, Mohammad
    Eshaghi, Mohammad Amin
    Esfahani, Mahboobe Fereidan
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2012, 20 (12) : 2519 - 2527