A novel modified screen-printed electrode with triazole surfactant assembled on silver nanoparticles for potentiometric determination of uranium

被引:8
|
作者
Akl, Zeinab Farouk [1 ]
Ali, Tamer Awad [2 ]
机构
[1] Egyptian Nucl & Radiol Regulatory Author, Nucl Safeguards & Phys Protect Dept, 3 Ahmed El Zomor St,POB 11762, Cairo, Egypt
[2] EPRI, Cairo 11727, Egypt
关键词
Uranyl ion; Screen-printed electrodes; Potentiometry; Silver nanoparticles; Triazole derivatives; SCHIFF-BASE COMPLEX; SELECTIVE DETERMINATION; GOLD NANOPARTICLES; CARBON NANOTUBES; SENSOR; WATER; SAMPLES; IONS; THORIUM; ACID;
D O I
10.1007/s10967-017-5524-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Potentiometric modified screen-printed electrodes were developed for UO2(II) determination using a triazole-derivative alone (MSPE) or self-assembled on silver nanoparticles- (SNPs-MSPE). The electrodes exhibited excellent potentiometric response characteristics with Nernstian slopes of 26.70 +/- 1.02 and 29.90 +/- 0.88 mV decade(-1) and detection limits of 1.00 x 10(-7) and 6.10 x 10(-10) mol L-1 for MSPE and SNPs-MSPE, respectively. The electrodes showed fast response times and independent response over a wide pH range. Effect of solution temperature was investigated in the range of 10-60 A degrees C. The optimized electrodes revealed good selectivity for UO2(II) over various interferant and were successfully employed to detect UO2(II) in different real samples.
引用
下载
收藏
页码:1865 / 1875
页数:11
相关论文
共 50 条
  • [1] A novel modified screen-printed electrode with triazole surfactant assembled on silver nanoparticles for potentiometric determination of uranium
    Zeinab Farouk Akl
    Tamer Awad Ali
    Journal of Radioanalytical and Nuclear Chemistry, 2017, 314 : 1865 - 1875
  • [2] Potentiometric determination of La(III) in polluted water samples using modified screen-printed electrode by self-assembled mercapto compound on silver nanoparticles
    Ali, Tamer Awad
    Mohamed, Gehad G.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 216 : 542 - 550
  • [3] Modified Screen-Printed Electrode for Potentiometric Determination of Copper(II) in Water Samples
    Ali, Tamer Awad
    Mohamed, Gehad G.
    El-Dessouky, Maher M. I.
    Abou El-Ella, Salwa M.
    Mohamed, Rabab T. F.
    JOURNAL OF SOLUTION CHEMISTRY, 2013, 42 (06) : 1336 - 1354
  • [4] Modified Screen-Printed Electrode for Potentiometric Determination of Copper(II) in Water Samples
    Tamer Awad Ali
    Gehad G. Mohamed
    Maher M. I. El-Dessouky
    Salwa M. Abou El-Ella
    Rabab T. F. Mohamed
    Journal of Solution Chemistry, 2013, 42 : 1336 - 1354
  • [5] Thiol surfactant assembled on gold nanoparticles ion exchanger for screen-printed electrode fabrication. Potentiometric determination of Ce(III) in environmental polluted samples
    Ali, Tamer Awad
    Mohamed, Gehad G.
    Azzam, E. M. S.
    Abd-elaal, Ali A.
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 191 : 192 - 203
  • [6] Potentiometric determination of mercury (II) ion in various real samples using novel modified screen-printed electrode
    Refaat F. Aglan
    Hosam M. Saleh
    Gehad G. Mohamed
    Applied Water Science, 2018, 8
  • [7] Potentiometric determination of mercury (II) ion in various real samples using novel modified screen-printed electrode
    Aglan, Refaat F.
    Saleh, Hosam M.
    Mohamed, Gehad G.
    APPLIED WATER SCIENCE, 2018, 8 (05)
  • [8] Direct As(V) Determination Using Screen-Printed Electrodes Modified with Silver Nanoparticles
    Torres-Rivero, Karina
    Perez-Rafols, Clara
    Bastos-Arrieta, Julio
    Florido, Antonio
    Marti, Vicenc
    Serrano, Nuria
    NANOMATERIALS, 2020, 10 (07) : 1 - 10
  • [9] Flow injection amperometric determination of isoniazid using a screen-printed carbon electrode modified with silver hexacyanoferrates nanoparticles
    de Oliveira, Paulo Roberto
    Oliveira, Marcela Mohallem
    Zarbin, Aldo J. G.
    Marcolino-Junior, Luiz Humberto
    Bergamini, Marcio F.
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 171 : 795 - 802
  • [10] SCREEN-PRINTED ELECTRODE MODIFIED WITH SILVER HEXACYANOFERRATE-NAFION® FOR ASCORBIC ACID DETERMINATION
    Mattos, I. L.
    Padilla, F.
    Zagal, J. H.
    Falcao, E. H. L.
    Segura, R.
    JOURNAL OF THE CHILEAN CHEMICAL SOCIETY, 2011, 56 (03): : 803 - 807