Sequential Injection System for Analysis of Degree Brix, Orthophosphate and pH in Raw Sugarcane Juice Applicable to Sugar Industry

被引:5
|
作者
Saetear, Phoonthawee [1 ,2 ,3 ]
Saechua, Nattinee [1 ,2 ,3 ]
Sereenonchai, Kamonthip [1 ,4 ]
机构
[1] Mahidol Univ, Flow Innovat Res Sci & Technol Labs, Firstlabs, Rama 6 Rd, Bangkok 10400, Thailand
[2] Mahidol Univ, Dept Chem, Bangkok 10400, Thailand
[3] Mahidol Univ, Ctr Excellence Innovat Chem, Fac Sci, Bangkok 10400, Thailand
[4] Thammasat Univ, Fac Sci & Technol, Dept Chem, Pathum Thani 12120, Thailand
来源
MOLECULES | 2021年 / 26卷 / 21期
关键词
sugarcane juice; pH; Brix; phosphate; schlieren effect; molybdenum blue; ISFET; sequential injection; FLOW-INJECTION; LIQUID-CHROMATOGRAPHY; REDUCING SUGARS; SOFT DRINK; CANE JUICE; PHOSPHATE; SUCROSE; SACCHARIDES; CALCIUM; WATERS;
D O I
10.3390/molecules26216484
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
This work presents, for the first time, a new sequential injection analysis (SIA) method to simultaneously analyze degree Brix, orthophosphate and pH in raw cane juice. These key parameters relate to price of harvested sugarcane and quality of cane juice for sugar production. The SIA system employed two detectors: the first detector is a diode-array spectrophotometer, equipped with a regular flow cell, for measurements of degree Brix and orthophosphate. Quantitative of degree Brix (& DEG;Bx; ca. % (w/w) sucrose) was based on manipulation of the schlieren effect at the interface between plugs of sample and water. Orthophosphate analysis was carried out based on the molybdenum blue method with significant reduction in consumption of the reagents. Compensation of the schlieren effect from sucrose for determination of orthophosphate was achieved by using a dual-wavelength spectrometric detection. Second detector is a pH-sensing device, called ion-selective field-effect transistors (ISFET). The ISFET is based on the current through the ISFET arising according to the H+ concentration in solution. Our developed SIA system provides linear calibration graphs fitting for purpose in analysis of sugarcane juice (pH: 0-14, & DEG;Bx: 1.0-7.0 and P2O5: 20-200 mg L-1). Simultaneous analysis of sugarcane juice for pH, & DEG;Bx and P2O5 is carried out within 5 min (12 sample per h). Precision of SIA system is acceptable (RSD < 3%). Our SIA system gave quantitative results insignificantly different, as compared with conventional methods for analysis of pH, & DEG;Bx and P2O5 in sugarcane juice.
引用
收藏
页数:16
相关论文
共 2 条
  • [1] System Dynamics Analysis of Sugarcane Supply Chain in Indian Sugar Industry
    Singh, Sandeep
    Srivastava, Samir K.
    Jangirala, Srinivas
    GLOBAL BUSINESS REVIEW, 2021,
  • [2] Sequential injection analysis system with DGA resin for sample pretreatment in ICP-MS determination of 239Pu in nuclear industry samples
    Kolacinska, Kamila
    DeVol, Timothy A.
    Seliman, Ayman F.
    Dudek, Jakub
    Trojanowicz, Marek
    MICROCHEMICAL JOURNAL, 2020, 152