On-line Partial Discharge Source Location in Single-core Cables with Multi Sheath-ground Connections

被引:3
|
作者
Babaee, Abbas [1 ]
Shahrtash, S. Mohammad [1 ]
机构
[1] Iran Univ Sci & Technol, Ctr Excellence Power Syst Automat & Operat, Tehran, Iran
关键词
Partial Discharge; PD location; on-line test; PD pulse propagation; multi-grounded connection; cable; COMPENSATION; ARRIVAL; PULSES;
D O I
10.1109/TDEI.2015.7076805
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents an on-line method for location of single partial discharge (PD) source on a cable network with multi sheath-ground connections. The main approach relies on comparing those transient components of currents passing through any two adjacent sheath-ground connections that relate to each other only by parameters of in-between cable. The proposed method is more reliable than the methods based on wave arrival time (ATA), due to processing on more than single points of the two considered PD pulses, which is the basis of ATA methods. This approach is then employed in discrimination between internal and external PD sources on a cable section and also location of an internal PD source on defected cable section. Comprehensive and straightforward guidelines for applying the proposed algorithm in any on-line applications are given. The proposed algorithm has shown accurate simulation results for various PD source characteristics, cable properties, and PD source locations even with additive noise on reference signals.
引用
收藏
页码:1031 / 1041
页数:11
相关论文
共 8 条
  • [1] Effect of ground return path on partial discharge signal propagation along single-core and three-core power cables
    Li, Yan
    Wu, Lei
    Wouters, Peter A. A. F.
    Wagenaars, Paul
    van der Wielen, Peter C. J. M.
    Steennis, E. Fred
    [J]. INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2016, 26 (08): : 1783 - 1798
  • [2] Research on the insulation on-line monitoring of single-core XPLE cable metal sheath
    CEEE, Huazhong University of Science and Technology, Wuhan 430074, China
    [J]. Gaoya Dianqi, 2006, 2 (90-92):
  • [3] On-line Partial Discharge Defected Phase Selection and Localization in Cross-bonded Single Core Cables
    Babaee, Abbas
    Shahrtash, S. Mohammad
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (05) : 2995 - 3006
  • [4] The location of partial discharge sources in power cables: an on-line, low-cost solution
    Lin, Yu-Hsun
    [J]. PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 1236 - 1241
  • [5] Circulating current method for the on-line monitoring of the multipoint earthing on the metal sheath of the single-core XLPE cable
    Chen, Chuangting
    Zhang, Guosheng
    Zhou, Zhicheng
    Zhang, Dandan
    Chen, Junwu
    He, Junjia
    Wang, Yan
    Li, Zhengying
    [J]. Gaodianya Jishu/High Voltage Engineering, 2002, 28 (07):
  • [6] On-line partial discharge monitoring system for underground MV cables - Part II: Detection and location
    Milioudis, Apostolos
    Andreou, Georgios
    Labridis, Dimitris
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2019, 109 : 395 - 402
  • [7] A centralized condition monitoring system for MV power cables based on on-line partial discharge detection and location
    van der Wielen, Peter C. J. M.
    Steennis, E. Fred
    [J]. PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 1166 - 1170
  • [8] On-Line Monitoring and Positioning of Sheath Grounding for High-Voltage Single-Core Cable Based on Pulse Difference Method
    Chen, Jiahui
    Che, Renfei
    Zhang, Muye
    [J]. 2021 3RD ASIA ENERGY AND ELECTRICAL ENGINEERING SYMPOSIUM (AEEES 2021), 2021, : 27 - 31