A Room-Temperature Pre-calibration Procedure for Gradiometer Sifting

被引:1
|
作者
Zhang Shu-Lin [1 ,2 ]
Liu Yang-Bo [1 ,2 ]
Liu Ming [3 ]
Wang Yong-Liang [1 ]
Kong Xiang-Yan [1 ]
Xie Xiao-Ming [1 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Microsyst & Informat Technol, State Key Lab Funct Mat Informat, Shanghai 200050, Peoples R China
[2] Chinese Acad Sci, Grad Univ, Beijing 100190, Peoples R China
[3] Univ Sci & Technol China, Dept Elect Sci & Technol, Hefei 230026, Peoples R China
关键词
SQUID-MAGNETOMETER;
D O I
10.1088/0256-307X/28/3/038501
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
In order to detect extremely weak magnetic signals, superconducting quantum interference device (SQUID) gradiometers are widely used to suppress environmental noise. A hardware SQUID gradiometer consists of a niobium gradio-antenna and an SQUID, which are coupled via an input coil. Here gradiometer imbalance may greatly reduce its noise suppression performance. The gradiometer balance depends on the geometrical forms of the antenna wound by niobium wire. We describe a simple method based on Faraday's law for the pre-calibration of the gradiometer balance at room temperature, before the gradiometer is set up. The pre-calibrating results are compared with the measured balance of an SQUID gradiometer system. This method may be used for sifting hardware gradiometers for multi-channel systems.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] Calibration: Pre-Calibration Routines
    Reu, Phillip
    EXPERIMENTAL TECHNIQUES, 2013, 37 (04) : 1 - 2
  • [2] COARSE BALANCING A SUPERCONDUCTING GRADIOMETER AT ROOM-TEMPERATURE
    VAD, K
    MESZAROS, S
    CRYOGENICS, 1984, 24 (09) : 460 - 460
  • [3] Calibration: Pre-calibration routines
    Phillip Reu
    Experimental Techniques, 2013, 37 : 1 - 2
  • [4] IBIS Mask pre-calibration matrix
    Reglero, V
    Sánchez, F
    Rodrigo, J
    Velasco, T
    Gasent, JL
    Chato, R
    Alamo, J
    Burgos, JA
    Suso, J
    Blay, P
    Martínez, S
    Doñate, M
    Reina, M
    Sabau, D
    Ruiz-Urien, I
    Santos, I
    Zarauz, J
    EXPLORING THE GAMMA-RAY UNIVERSE, 2001, 459 : 619 - 622
  • [5] A Pre-calibration Method for Concrete Distributor
    Zhou, Peng
    Guo, Jingjing
    Li, Dong
    Zhang, Ke
    Zou, Defang
    PROCEEDINGS OF THE 2019 31ST CHINESE CONTROL AND DECISION CONFERENCE (CCDC 2019), 2019, : 3683 - 3686
  • [6] Development of a room-temperature gradiometer system for underground structure detection and characterization
    Dalichaouch, Y
    Perry, AR
    Whitecotton, B
    Moeller, C
    Czipott, PV
    UNATTENDED GROUND SENSOR TECHNOLOGIES AND APPLICATIONS II, 2000, 4040 : 74 - 82
  • [7] Calculations for the pre-calibration of LAMOST active optics
    Zhang, Y
    Cui, XQ
    CHINESE JOURNAL OF ASTRONOMY AND ASTROPHYSICS, 2005, 5 (03): : 302 - 314
  • [8] Calculations for the Pre-Calibration of LAMOST Active Optics
    Yong Zhang and Xiang-Qun Cui National Astronomical Observatories / Nanjing Institute of Astronomical Optics & Technology
    Graduate School of the Chinese Academy of Sciences
    Chinese Journal of Astronomy and Astrophysics, 2005, (03) : 302 - 314
  • [9] Radiometric pre-Calibration of Alsat-1 Camera
    Rachedi, A.
    Belkacemi, K.
    Benbouzid, A. B.
    Laidi, K.
    Belghoraf, A.
    Sweeting, Martin N.
    RAST 2009: PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON RECENT ADVANCES IN SPACE TECHNOLOGIES, 2009, : 361 - 366
  • [10] Relative pre-calibration of the ALICE electromagnetic calorimeter EMCAL
    Faivre, J.
    XIV INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS (CALOR 2010), 2011, 293