Development of Non-Invasive Blood-Glucose Measurement System

被引:0
|
作者
Anas, M. N. [1 ]
Lim, P. K. [1 ]
机构
[1] Univ Malaysia Perlis, Sch Mechatron Engn, Arau 02600, Malaysia
关键词
Blood-glucose; Bioelectrical Impedance; Constant current source; Non-Invasive measurement; IMPEDANCE;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Diabetes is already the world's most costly epidemic. Current glucose monitoring are invasive, which requires painful procedures and not reliable for long term usage. Impedance of human skin provides details about physiological structure and chemical composition of the skin and underneath tissues. Glucose concentration will affect the dielectric properties of cellular membranes, and therefore, changing the impedance of the blood. This paper describes a non-invasive measurement continuous glucose monitoring system based on bioelectrical impedance. In this project, an alternative current constant current source with a frequency of 50kHz and peak-to-peak of 1 mA is developed and injected to the finger tip through the developed tetra-polar electrode. The voltage drop across the finger will be measured and also used to determine the variation on glucose concentration. The developed prototype device will help to manage the painful procedures, cost-effective and reduce the infection rate as compared to the conventional invasive technique. Preliminary results show that 80% of measurement accuracy of the developed system measured non-invasively blood-glucose by means of bioelectrical impedance.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] A microwave frequency sensor for non-invasive blood-glucose measurement
    Jean, Buford Randall
    Green, Eric C.
    McClung, Melanie J.
    [J]. 2008 IEEE SENSORS APPLICATIONS SYMPOSIUM, 2008, : 4 - 7
  • [2] Non-invasive Blood Glucose Measurement System
    Deepthi, S.
    Valke, Nikita S.
    Parvathy, J. P.
    Sai, Anjaly Krishna
    Sajjan, Guttappa
    [J]. 2019 5TH IEEE INTERNATIONAL WIE CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (WIECON-ECE 2019), 2019,
  • [3] Derivative Spectroscopy in Non-Invasive Blood-Glucose Analysis
    Dontu, Vishnu
    [J]. 2016 IEEE FIRST INTERNATIONAL CONFERENCE ON CONNECTED HEALTH: APPLICATIONS, SYSTEMS AND ENGINEERING TECHNOLOGIES (CHASE), 2016, : 350 - 351
  • [4] A novel system for non-invasive measurement of blood levels of glucose
    Tysoe, Olivia
    [J]. NATURE REVIEWS ENDOCRINOLOGY, 2024, 20 (06) : 320 - 320
  • [5] An Optimized Non-Invasive Blood Glucose and Temperature Body Measurement System
    Ibrahim, Hagar
    Darweesh, M. Saeed
    Soltan, Ahmed
    [J]. 2022 11TH INTERNATIONAL CONFERENCE ON MODERN CIRCUITS AND SYSTEMS TECHNOLOGIES (MOCAST), 2022,
  • [6] An IoMT based Non-Invasive Precise Blood Glucose Measurement System
    Jain, Prateek
    Pancholi, Sidharth
    Joshi, Amit M.
    [J]. 2019 IEEE INTERNATIONAL SYMPOSIUM ON SMART ELECTRONIC SYSTEMS (ISES 2019), 2019, : 111 - 116
  • [7] Non-invasive blood glucose measurement Measurement of bioeletrical signal
    Anas, M. N.
    Nurun, N. K.
    Noral, A. N.
    Normahira, M.
    [J]. 2012 IEEE EMBS CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES), 2012,
  • [8] Overviews the Methods of non-invasive Blood glucose measurement
    Liu, Yuwei
    Li, Weixi
    Zheng, Tuhong
    Ling, Wing-Kuen
    [J]. 2016 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS-CHINA (ICCE-CHINA), 2016,
  • [9] Multiparameter techniques for non-invasive measurement of blood glucose
    Amaral, Carlos F.
    Brischwein, Martin
    Wolf, Bernhard
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2009, 140 (01): : 12 - 16
  • [10] Method and device for non-invasive blood glucose measurement
    Amerov, AK
    Jeon, KJ
    Kim, YJ
    Yoon, G
    [J]. OPTICAL DIAGNOSTICS OF BIOLOGICAL FLUIDS IV, PROCEEDINGS OF, 1999, 3599 : 33 - 42