A Study on Actual Conditions of Thermal Environment and Indoor Air Quality in a Japanese Traditional House Corresponding to Sericulture

被引:2
|
作者
Wang, Yan [1 ]
Yoshino, Yasuko [2 ]
Kumagai, Kazukiyo [3 ]
Takahashi, Miyuki [4 ]
机构
[1] Nihon Univ, Grad Sch, Funabashi, Chiba, Japan
[2] Nihon Univ, Jr Coll, Funabashi, Chiba, Japan
[3] Kyushu Univ, Res & Educ Ctr Carbon Resources, Fukuoka 812, Japan
[4] Setagaya Ward Educ Board, Tokyo, Japan
关键词
silkworm hearth; field measurement; thermal environment; IAQ; ventilation volume; simulation;
D O I
10.3130/jaabe.9.509
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study of the traditional sericulture residence, located inside the Minkaen, Jidayubori Park, Setagaya Ward, Tokyo, Japan, aims to clarify the environmental characteristics of a sericulture building from the engineering point of view. In sericulture, the silkworms are raised at different locations depending on their age. Therefore we describe the actual conditions of the thermal environment such as temperature and humidity when the silkworm is breeding, and the air quality such as CO2, CO, VOC, and carbonyl compound from the silkworm hearth. In addition to these factors the ventilation rate in each part of the traditional house corresponding to sericulture is determined. Moreover, the ventilation performance of the attic and the monitor roof is investigated. The mechanism of thermal conditions, IAQ and ventilation rate was clarified in this paper for the first time using the three-dimensional heat fluid simulation software. As described thus far, we have clarified the environmental situation in a sericulture house from the engineering point of view.
引用
收藏
页码:509 / 514
页数:6
相关论文
共 50 条
  • [1] Actual conditions and its mechanism on thermal environment and indoor air quality in a Japanese traditional house corresponding to sericulture
    Wang, Yan
    Yoshino, Yasuko
    Kumagai, Kazukiyo
    Sekiguchi, Katsuaki
    FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 907 - 914
  • [2] Actual conditions and the mechanism of thermal environment and indoor air quality in a traditional house corresponding to sericultural buildings
    Wang, Yan
    Yoshino, Yasuko
    Kumagai, Kazukiyo
    Takahashi, Miyuki
    Sekiguchi, Katsuaki
    Journal of Environmental Engineering, 2008, 73 (634) : 1451 - 1455
  • [3] HVAC design conditions, actual indoor air quality and thermal environment of patient rooms in Japan
    Tanaka, H
    Nagura, H
    Baba, H
    Okumiya, M
    Yamashita, T
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 1237 - 1242
  • [4] Experimental Study on the Influence of a Ventilated Window for Indoor Air Quality and Indoor Thermal Environment
    Jin, Wufeng
    Zhang, Ningning
    He, Junwei
    9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 217 - 224
  • [5] A sustainable localised air distribution system for enhancing thermal environment and indoor air quality of poultry house for semiarid region
    Al Assaad, Douaa K.
    Orabi, Mohamad S.
    Ghaddar, Nesreen K.
    Ghali, Kamel F.
    Salam, Darine A.
    Ouahrani, Djamel
    Farran, Mohamad T.
    Habib, Rima R.
    BIOSYSTEMS ENGINEERING, 2021, 203 : 70 - 92
  • [6] Impact of windcatcher on the thermal comfort and indoor air quality in a modern house
    Mamari, Manal Al
    Khan, Hayder Murad
    Al Saadi, Saleh
    Al Hashim, Alya
    BUILDING RESEARCH AND INFORMATION, 2025, 53 (1-2): : 204 - 219
  • [7] Critical review of standards for indoor thermal environment and air quality
    Khovalyg, Dolaana
    Kazanci, Ongun B.
    Halvorsen, Hanne
    Gundlach, Ida
    Bahnfleth, William P.
    Toftum, Jorn
    Olesen, Bjarne W.
    ENERGY AND BUILDINGS, 2020, 213
  • [8] SPATIAL-DISTRIBUTION OF THORON AND RADON CONCENTRATIONS IN THE INDOOR AIR OF A TRADITIONAL JAPANESE WOODEN HOUSE
    DOI, M
    FUJIMOTO, K
    KOBAYASHI, S
    YONEHARA, H
    HEALTH PHYSICS, 1994, 66 (01): : 43 - 49
  • [9] The Study of Indoor Air Thermal Environment and Energy in Winter
    Tang, Zhonghua
    2010 THE SECOND CHINA ENERGY SCIENTIST FORUM, VOL 1-3, 2010, : 177 - 181
  • [10] Evaluation of the influence of one air circulation system on LGS house indoor thermal environment
    Li, Jing
    Deng, Zhi-qiang
    Li, Chuan
    Zhou, Di
    PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING, PTS. 1-5, 2012, 204-208 : 4343 - 4348