MR Angiography at 3 Tesla to Assess Proximal Internal Carotid Artery Stenoses: Contrast-Enhanced or 3D Time-of-Flight MR Angiography?

被引:25
|
作者
Weber, J. [1 ]
Veith, P. [1 ]
Jung, B. [2 ,3 ]
Ihorst, G. [4 ]
Moske-Eick, O. [1 ]
Meckel, S. [1 ]
Urbach, H. [1 ]
Taschner, C. A. [1 ]
机构
[1] Univ Hosp Freiburg, Dept Neuroradiol, Neuroctr, D-79106 Freiburg, Germany
[2] Univ Hosp Freiburg, Dept Radiol, Med Phys, D-79106 Freiburg, Germany
[3] Univ Hosp Bern, Dept Radiol, CH-3010 Bern, Switzerland
[4] Univ Freiburg, Clin Trials Ctr, D-79106 Freiburg, Germany
关键词
Carotid stenosis; 3D TOF-MRA; CE-MRA; 3; Tesla; MDCTA; MAGNETIC-RESONANCE ANGIOGRAPHY; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; MULTIDETECTOR-ROW CT; CEREBRAL-ANGIOGRAPHY; NEUROLOGIC COMPLICATIONS; ROTATIONAL ANGIOGRAPHY; DIAGNOSTIC-ACCURACY; IMAGING MODALITY; ENDARTERECTOMY; QUANTIFICATION;
D O I
10.1007/s00062-013-0279-x
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The aim of this study was to compare the diagnostic accuracy of 3D time-of-flight (TOF-MRA) and contrast-enhanced (CE-MRA) magnetic resonance angiography at 3 T for detection and quantification of proximal high-grade stenosis using multidetector computed tomography angiography (MDCTA) as reference standard. The institutional ethics committee approved this prospective study. A total of 41 patients suspected of having internal carotid artery (ICA) stenosis underwent both MDCTA and MRA. CE-MRA and TOF-MRA were performed using a 3.0-T imager with a dedicated eight-element cervical coil. ICA stenoses were measured according to the North American Symptomatic Carotid Endarterectomy Trial criteria and categorized as 0-25 % (minimal), 25-50 % (mild), 50-69 % (moderate), 70-99 % (high grade), and 100 % (occlusion). Sensitivity and specificity for the detection of high-grade ICA stenoses (70-99 %) and ICA occlusions were determined. In addition, intermodality agreement was assessed with kappa-statistics for detection of high-grade ICA stenoses (70-99 %) and ICA occlusions. A total of 80 carotid arteries of 41 patients were reviewed. Two previously stented ICAs were excluded from analysis. On MDCTA, 7 ICAs were occluded, 12 ICAs presented with and 63 without a high-grade ICA stenosis (70-99 %). For detecting 70-99 % stenosis, both 3D TOF-MRA and CE-MRA were 91.7 % sensitive and 98.5 % specific, respectively. Both MRA techniques were highly sensitive (100 %), and specific (CE-MRA, 100 %; TOF-MRA, 98.7 %) for the detection of ICA occlusion. However, TOF-MRA misclassified one high-grade stenosis as occlusion. Intermodality agreement for detection of 70-99 % ICA stenoses was excellent between TOF-MRA and CE-MRA [kappa = 0.902, 95 % confidence interval (CI) = 0.769-1.000], TOF-MRA and MDCTA (kappa = 0.902, 95 % CI = 0.769-1.000), and CE-MRA and MDCTA (kappa = 0.902, 95 % CI = 0.769-1.000). Both 3D TOF-MRA and CE-MRA at 3 T are reliable tools for detecting high-grade proximal ICA stenoses (70-99 %). 3D TOF-MRA might misclassify pseudo-occlusions as complete occlusions. If there are no contraindications for CE-MRA, CE-MRA is recommended as primary MR imaging modality.
引用
收藏
页码:41 / 48
页数:8
相关论文
共 50 条
  • [1] MR Angiography at 3 Tesla to Assess Proximal Internal Carotid Artery Stenoses: Contrast-Enhanced or 3D Time-of-Flight MR Angiography?
    J. Weber
    P. Veith
    B. Jung
    G. Ihorst
    O. Moske-Eick
    S. Meckel
    H. Urbach
    C. A. Taschner
    Clinical Neuroradiology, 2015, 25 : 41 - 48
  • [2] Carotid Artery Stenosis: Comparison of 3D Time-of-Flight MR Angiography and Contrast-Enhanced MR Angiography at 3T
    Platzek, Ivan
    Sieron, Dominik
    Wiggermann, Philipp
    Laniado, Michael
    RADIOLOGY RESEARCH AND PRACTICE, 2014, 2014
  • [3] Contrast-enhanced 3D MR angiography of moyamoya disease: Comparison with conventional 3D time-of-flight MR angiography
    Yoon, H
    Shin, H
    Na, D
    Cho, Y
    Han, BK
    RADIOLOGY, 2000, 217 : 429 - 429
  • [4] Carotid artery stenosis: Intraindividual correlations of 3D time-of-flight MR angiography, contrast-enhanced MR angiography, conventional DSA, and rotational angiography for detection and grading
    Anzalone, N
    Scomazzoni, F
    Castellano, R
    Strada, L
    Righi, C
    Politi, LS
    Kirchin, MA
    Chiesa, R
    Scotti, G
    RADIOLOGY, 2005, 236 (01) : 204 - 213
  • [5] Contrast-enhanced 3D MR DSA of the carotid artery bifurcation: Preliminary study of comparison with unenhanced 2D and 3D time-of-flight MR angiography
    Willig, DS
    Turski, PA
    Frayne, R
    Graves, VB
    Korosec, FR
    Swan, JS
    Mistretta, CA
    Grist, TM
    RADIOLOGY, 1998, 208 (02) : 447 - 451
  • [6] 3D Contrast-enhanced MR angiography
    Zhang, HongLei
    Maki, Jeffrey H.
    Prince, Martin R.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (01) : 13 - 25
  • [7] Contrast-enhanced 3D MR angiography of the carotid artery:: Comparison with conventional digital subtraction angiography
    Remonda, L
    Senn, P
    Barth, A
    Arnold, M
    Lövblad, KO
    Schroth, G
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2002, 23 (02) : 213 - 219
  • [8] Contrast-Enhanced MR Angiography Is Not More Accurate Than Unenhanced 2D Time-of-Flight MR Angiography for Determining ≥70% Internal Carotid Artery Stenosis
    Babiarz, L. S.
    Romero, J. M.
    Murphy, E. K.
    Brobeck, B.
    Schaefer, P. W.
    Gonzalez, R. G.
    Lev, M. H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (04) : 761 - 768
  • [9] Contrast-enhanced MR angiography at 3T in the evaluation of intracranial aneurysms: A comparison with time-of-flight MR angiography
    Nael, K.
    Villablanca, J. P.
    Saleh, R.
    Pope, W.
    Nael, A.
    Laub, G.
    Finn, J. P.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2006, 27 (10) : 2118 - 2121
  • [10] Follow-up of coiled cerebral aneurysms at 3T: Comparison of 3D time-of-flight MR angiography and contrast-enhanced MR angiography
    Anzalone, N.
    Scomazzoni, F.
    Cirillo, M.
    Righi, C.
    Simionato, F.
    Cadioli, M.
    Iadanza, A.
    Kirchin, M. A.
    Scotti, G.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (08) : 1530 - 1536