Light output from six battery operated dental curing lights

被引:36
|
作者
Kenji Shimokawa, Carlos Alberto [1 ,2 ]
Turbino, Miriam Lacalle [1 ]
Harlow, Jessie Eudora [2 ]
Price, Hannah Louise [2 ]
Price, Richard Bengt [3 ,4 ]
机构
[1] Univ Sao Paulo, Sch Dent, Restorat Dent, Ave Prof Lineu Prestes 2227, BR-05508000 Sao Paulo, SP, Brazil
[2] Dalhousie Univ, Dent Clin Sci, Fac Dent, 5981 Univ Ave, Halifax, NS B3H 4R2, Canada
[3] Dalhousie Univ, Sch Biomed Engn, 5981 Univ Ave, Halifax, NS B3H 4R2, Canada
[4] Dalhousie Univ, Fac Dent, 5981 Univ Ave, Halifax, NS B3H 4R2, Canada
来源
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS | 2016年 / 69卷
关键词
Dental curing lights; Dental equipment; Beam profile; Emission spectrum analysis; Radiometry; ARGON ION LASER; COMPOSITE RESIN; HALOGEN LIGHT; CONVERSION; UNITS; ADHESIVES; DIODE; CURE;
D O I
10.1016/j.msec.2016.07.033
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Light Curing Units (LCUs) are used daily in almost every dental office to photocure resins, but because the light is so bright, the user is unable to tell visually if there are any differences between different LCUs. This study evaluated the light output from six dental LCUs: Elipar Deep Cure-S (3M ESPE), Bluephase G2 (Ivoclar Vivadent), Translux 2Wave (Heraeus Kulzer), Optilight Prime (Gnatus), Slim Blast (First Medica) and Led.B (Guilin Woodpecker) with a fully charged battery, after 50, and again after 100, 20 second light exposures. For each situation, the radiant power was measured 10 times with a laboratory-grade power meter. Then, the emission spectrum was measured using a fiber-optic spectrometer followed by an analysis of the light beam profile. It was found there were significant differences in the LCU power and the irradiance values between the LCUs (p < 0.01). The Optilight Prime and Slim Blast LCUs showed a significant reduction in light output after a 50 and 100 exposures, while Bluephase G2 exhibited a significant reduction only after 100 exposures (p < 0.01). The Bluephase G2 and Translux 2 Wave delivered an emission spectrum that had two distinct wavelength emission peaks. Only the Elipar Deep Cure-S and Bluephase G2 LCUs displayed homogeneous light beam profiles, the other LCUs exhibited highly non-homogeneous light beam profiles. It was concluded that contemporary LCUs could have very different light output characteristics. Both manufacturers and researchers should provide more information about the light output from LCUs. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:1036 / 1042
页数:7
相关论文
共 50 条
  • [1] Ability of four dental radiometers to measure the light output from nine curing lights
    Kenji Shimokawa, Carlos Alberto
    Harlow, Jessie Eudora
    Turbino, Miriam Lacalle
    Price, Richard Bengt
    JOURNAL OF DENTISTRY, 2016, 54 : 48 - 55
  • [2] Characterizing the output settings of dental curing lights
    Harlow, J. E.
    Sullivan, B.
    Shortall, A. C.
    Labrie, D.
    Price, R. B.
    JOURNAL OF DENTISTRY, 2016, 44 : 20 - 26
  • [3] Energy output of dental school curing lights.
    Pagniano, RP
    Ayad, M
    JOURNAL OF DENTAL RESEARCH, 1996, 75 : 2925 - 2925
  • [4] EVALUATING INTENSITY OUTPUT OF CURING LIGHTS IN PRIVATE DENTAL OFFICES
    BARGHI, N
    BERRY, T
    HATTON, C
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1994, 125 (07): : 992 - 996
  • [5] Response of THP-1 monocytes to blue light from dental curing lights
    Wataha, J. C.
    Lewis, J. B.
    Lockwood, P. E.
    Noda, M.
    Messer, R. L.
    Hsu, S.
    JOURNAL OF ORAL REHABILITATION, 2008, 35 (02) : 105 - 110
  • [6] Output intensity of curing lights.
    Cohen, E
    DellaBona, A
    JOURNAL OF DENTAL RESEARCH, 1996, 75 (05) : 1095 - 1095
  • [7] Evaluation of radiometers for dental curing lights
    Rossouw, S
    Pieters, MM
    Van der Grijp, I
    JOURNAL OF DENTAL RESEARCH, 2001, 80 (04) : 1361 - 1361
  • [8] The effect of distance from light source on light intensity from curing lights
    Felix, CA
    Price, RBT
    JOURNAL OF ADHESIVE DENTISTRY, 2003, 5 (04): : 283 - 291
  • [9] OPTICAL HAZARD EVALUATION OF DENTAL CURING LIGHTS
    ERIKSEN, P
    MOSCATO, PM
    FRANKS, JK
    SLINEY, DH
    COMMUNITY DENTISTRY AND ORAL EPIDEMIOLOGY, 1987, 15 (04) : 197 - 201
  • [10] Evaluating intensity and heat output of curing lights.
    Casalli, JL
    DellaBona, A
    Schleder, PV
    JOURNAL OF DENTAL RESEARCH, 1997, 76 (05) : 996 - 996