In vitro comparative testing of fracture fixation implants is limited by the highly variable material properties of cadaveric bone. Bone surrogate specimens are often employed to avoid this confounding variable. Although validated surrogate models of normal bone (NB) exist, no validated bone model simulating weak, osteoporotic bone (OPB) is available. This study presents an osteoporotic long-bone model designed to match the lower cumulative range of mechanical properties found in large series of cadaveric femora reported in the literature. Five key structural properties were identified from the literature: torsional rigidity and strength, bending rigidity and strength, and screw pull-out strength. An OPB surrogate was designed to meet the low range for each of these parameters, and was mechanically tested. For comparison, the same parameters were determined for surrogates of NB. The OPB surrogate had a torsional rigidity and torsional strength within the lower 2% and 16%, respectively, of the literature based cumulative range reported for cadaveric femurs. Its bending rigidity and bending strength was within the lower 11% and 8% of the literature-based range, respectively. Its pull-out strength was within the lower 2% to 16% of the literature based range. With all five structural properties being within the lower 16% of the cumulative range reported for native femurs, the OPB surrogate reflected the diminished structural properties seen in osteoporotic femora. In comparison, surrogates of NB demonstrated structural properties within 23-118% of the literature-based range. These results support the need and utility of the OPB surrogate for comparative testing of implants for fixation of femoral shaft fractures in OPB. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3297 / 3304
页数:8
相关论文
共 50 条
  • [1] Optimal administration frequency and dose of teriparatide for acceleration of biomechanical healing of long-bone fracture in a mouse model
    Ota, Masahiro
    Takahata, Masahiko
    Shimizu, Tomohiro
    Momma, Daisuke
    Hamano, Hiroki
    Hiratsuka, Shigeto
    Amizuka, Norio
    Hasegawa, Tomoka
    Iwasaki, Norimasa
    JOURNAL OF BONE AND MINERAL METABOLISM, 2019, 37 (02) : 256 - 263
  • [2] Optimal administration frequency and dose of teriparatide for acceleration of biomechanical healing of long-bone fracture in a mouse model
    Masahiro Ota
    Masahiko Takahata
    Tomohiro Shimizu
    Daisuke Momma
    Hiroki Hamano
    Shigeto Hiratsuka
    Norio Amizuka
    Tomoka Hasegawa
    Norimasa Iwasaki
    Journal of Bone and Mineral Metabolism, 2019, 37 : 256 - 263
  • [3] EFFECTS OF LITHIUM ON MOUSE OSTEOCLASTS AND ON THE BIOMECHANICAL PROPERTIES OF LONG-BONE IN THE RAT
    WILSON, AS
    PHILLIPS, JD
    BIRCH, NJ
    BIOCHEMICAL SOCIETY TRANSACTIONS, 1988, 16 (05) : 826 - 827
  • [4] Navigated Long-Bone Fracture Reduction
    Kahler, David M.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A : 102 - 107
  • [5] PRINCIPLES OF LONG-BONE FRACTURE MANAGEMENT
    BOUDRIEAU, RJ
    SINIBALDI, KR
    SEMINARS IN VETERINARY MEDICINE AND SURGERY-SMALL ANIMAL, 1992, 7 (01): : 44 - 62
  • [6] THE FATE OF MICROFRAGMENTS OF BONE IMPLANTS INTO THE MEDULLARY CAVITY OF A LONG-BONE
    GALLEY, A
    COULON, J
    PATRICOT, LM
    GASTELLU, J
    SOUZAFILHIO, R
    FISCHER, L
    LYON CHIRURGICAL, 1990, 86 (04) : 347 - 350
  • [7] Biomechanical considerations of fracture reduction and fixation in osteoporotic bone
    Chao, E
    Kim, Y
    Inoue, N
    OSTEOPOROSIS INTERNATIONAL, 2002, 13 : S4 - S4
  • [8] Limits of internal fixation in long-bone fracture
    Nieto, H.
    Baroan, C.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2017, 103 (01) : S61 - S66
  • [9] Assessment of stiffness and strength of 4 different implants available for equine fracture treatment:: A study on a 20° oblique long-bone fracture model using a bone substitute
    Florin, M
    Arzdorf, M
    Linke, B
    Auer, JA
    VETERINARY SURGERY, 2005, 34 (03) : 231 - 238
  • [10] SEMIRIGID ROD FIXATION FOR LONG-BONE FRACTURE
    WANG, GJ
    REGER, SI
    MABIE, KN
    RICHMAN, JA
    STAMP, WG
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1985, (192) : 291 - 298