Direct Comparison of Elastography Endoscopic Ultrasound Fine-Needle Aspiration and B-Mode Endoscopic Ultrasound Fine-Needle Aspiration in Diagnosing Solid Pancreatic Lesions

被引:7
|
作者
Gheorghiu, Marcel [1 ]
Sparchez, Zeno [1 ,2 ]
Rusu, Ioana [1 ,2 ]
Bolboaca, Sorana D. [3 ]
Seicean, Radu [4 ]
Pojoga, Cristina [2 ,5 ]
Seicean, Andrada [1 ,2 ]
机构
[1] Iuliu Hatieganu Univ Med & Pharm, Dept Gastroenterol, Cluj Napoca 400192, Romania
[2] Reg Inst Gastroenterol & Hepatol, Dept Gastroenterol, Prof Dr Octavian Fodor, Cluj Napoca 400192, Romania
[3] Iuliu Hatieganu Univ Med & Pharm, Dept Med Informat & BioStat, Cluj Napoca 400349, Romania
[4] Iuliu Hatieganu Univ Med & Pharm, Surg Dept 1, Cluj Napoca 400005, Romania
[5] Babes Bolyai Univ, Clin Psychol & Psychotherapy Dept, Cluj Napoca 400015, Romania
关键词
elastography; EUS-FNA (endoscopic ultrasound fine-needle aspiration); endoscopic ultrasound (EUS); fine needle aspiration (FNA); pancreatic cancer; diagnostic; histology; CONTRAST-ENHANCED EUS; GUIDED ELASTOGRAPHY; CLINICAL IMPACT; MASSES; FNA; ACCURACY; BIOPSY; TUMORS;
D O I
10.3390/ijerph19031302
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Elastography endoscopic ultrasound (E-EUS) has been proved to be a valuable supplement to endoscopic ultrasound fine-needle aspiration (EUS-FNA) in differentiating solid pancreatic lesions, but the improvement of EUS-FNA guided during E-EUS has not been proven. Our study aimed to evaluate whether E-EUS fine-needle aspiration (E-EUS-FNA) was superior to B-mode EUS-FNA for the diagnosis of solid pancreatic masses and whether the diagnostic rate was affected by specific factors. Our prospective study was conducted between 2019-2020 by recruiting patients with solid pancreatic masses. E-EUS examination was followed by one pass of E-EUS-FNA towards the blue part of the lesion and a second pass of EUS-FNA. The final diagnosis was based on surgery, E-EUS-FNA or EUS-FNA results, or a 12-month follow-up. Sixty patients with solid pancreatic lesions were evaluated. The sensitivity, specificity, and accuracy for diagnosing malignancy using E-EUS-FNA and EUS-FNA were 89.5%, 100%, 90%, 93%, 100%, and 93.3%, respectively, but the differences were not significant. Neither mass location nor the lesion size influenced the results. The lengths of the core obtained during E-EUS-FNA and EUS-FNA were similar. E-EUS-FNA in solid pancreatic lesions was not superior to B-mode EUS-FNA.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Comparison of Endoscopic Ultrasound Fine-Needle Aspiration and Fine-Needle Biopsy for Solid Pancreatic Masses
    Woldesellassie, Fitsum
    Cristian, Rios
    Ganguli, Surosree
    Thomas, Chandler
    Furmanek, Stephen
    McClave, Stephen
    Omer, Endashaw
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2019, 114 : S26 - S27
  • [2] A Comparison of Endoscopic Ultrasound-Guided Fine-Needle Aspiration and Fine-Needle Biopsy in the Diagnosis of Solid Pancreatic Lesions
    Ayres, Lachlan R.
    Kmiotek, Elizabeth K.
    Lam, Eric
    Telford, Jennifer J.
    [J]. CANADIAN JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2018, 2018
  • [3] Diagnostic accuracy of fine-needle aspiration of solid pancreatic lesions guided by endoscopic ultrasound elastography
    Facciorusso, Antonio
    Martina, Matteo
    Buccino, Rosario Vincenzo
    Nacchiero, Maurizio Cosimo
    Muscatiello, Nicola
    [J]. ANNALS OF GASTROENTEROLOGY, 2018, 31 (04): : 513 - 518
  • [4] Endoscopic ultrasound fine-needle aspiration for diagnosing gastroenterological disease
    Araki, M
    Kida, M
    Kikuchi, H
    Takezawa, M
    Yamazaki, Y
    Shirasu, K
    Shikama, N
    Kokuto, M
    Watanabe, M
    Kida, Y
    Imaizumi, H
    Yamada, Y
    Sakaguchi, T
    Saigenji, K
    [J]. GASTROINTESTINAL ENDOSCOPY, 2002, 56 (04) : S145 - S145
  • [5] Quantitative Elastography Versus Fine-needle Aspiration by Endoscopic Ultrasound for the Assessment of Pancreatic Solid Masses
    Hernandez Mondragon, Oscar V.
    Velez Resendiz, Juan M.
    Ruiz, Rodolfo R.
    [J]. JOURNAL OF CLINICAL GASTROENTEROLOGY, 2019, 53 (07) : E261 - E268
  • [6] The Role of Endoscopic Ultrasound-Guided Fine-Needle Aspiration of Pancreatic Lesions
    Yoshinaga, Shigetaka
    [J]. NORTH AMERICAN JOURNAL OF MEDICAL SCIENCES, 2016, 8 (01) : 12 - 12
  • [7] Diagnostic yield of endoscopic ultrasound with fine-needle aspiration in pancreatic cystic lesions
    Arguello, Lidia
    Sanchez-Montes, Cristina
    Mansilla-Vivar, Rodrigo
    Artes, Josefa
    Prieto, Mireya
    Alonso-Lazaro, Noelia
    Satorres-Paniagua, Carla
    Pons-Beltran, Vicente
    [J]. GASTROENTEROLOGIA Y HEPATOLOGIA, 2020, 43 (01): : 1 - 8
  • [9] Endoscopic ultrasound-guided fine-needle aspiration of solid liver lesions
    DeWitt, J
    LeBlanc, J
    McHenry, L
    Overton, J
    Sherman, S
    [J]. GASTROINTESTINAL ENDOSCOPY, 2002, 56 (04) : S131 - S131
  • [10] Comparison of Capillary Versus Aspiration Technique in Endoscopic Ultrasound-Guided Fine-Needle Aspiration for Solid Pancreatic Lesions
    Shah, Apeksha
    Khurana, Tanvi
    Malin, Jessica
    Hermna, Justin
    Ghumman, Saad
    Laique, Sobia
    Siddiqui, Ali
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2014, 109 : S84 - S84