Exergy analysis of a closed mechanical vapour compression desalination system by the entropy method

被引:1
|
作者
Yang, Junling [1 ]
Zhang, Zhentao [2 ]
Lin, Xuejun [2 ]
机构
[1] Tech Inst Phys & Chem, CAS Key Lab Cryogen, 29 Zhongguancun East Rd, Beijing, Peoples R China
[2] Tech Inst Phys & Chem, 29 Zhongguancun East Rd, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
Closed mechanical vapour compression; MVC; Desalination; Exergy loss; Entropy method; SEAWATER; PERFORMANCE; DESIGN; DRIVEN;
D O I
10.5004/dwt.2019.24427
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Corrosion is a common problem for desalination systems. To protect the compressor in a desalination system from being corroded and damaged, a novel mechanical vapour compression desalination system, denoted as a closed mechanical vapour compression desalination system, is proposed, in which the compressor does not contact the vapour produced by seawater directly. Mathematical models corresponding to the proposed system were established, and then an exergy analysis based on entropy method was achieved to investigate the performance of the system with a flow rate of 1,000 kg/h. The results showed that the total exergy loss was 29.4 kW, for which the circulating water tank accounts for 41% due to a superimposition of flashing and mixing, followed by the heat exchanger (23%), evaporator (16%), compressor (13%), preheater (5%) and pumps (1%). The exergy loss of the pumps is much smaller due to their lower power consumption.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 50 条
  • [1] Vapour Compression Flash seawater desalination system and its exergy analysis
    Jin, Cong-zhuo
    Chou, Qiao-li
    Jiao, Dong-sheng
    Shu, Peng-cheng
    [J]. DESALINATION, 2014, 353 : 75 - 83
  • [2] Analysis of mechanical vapour compression desalination process
    Ettouney, H
    El-Dessouky, H
    Al-Roumi, Y
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1999, 23 (05) : 431 - 451
  • [3] Entropy generation and exergy destruction analyses for vapour compression refrigeration system with various refrigerants
    Ankur Geete
    Mamta Sharma
    Pranjal Shrimali
    [J]. SN Applied Sciences, 2019, 1
  • [4] Entropy generation and exergy destruction analyses for vapour compression refrigeration system with various refrigerants
    Geete, Ankur
    Sharma, Mamta
    Shrimali, Pranjal
    [J]. SN APPLIED SCIENCES, 2019, 1 (07)
  • [5] Analysis of a mechanical vapor compression desalination system
    Aybar, HS
    [J]. DESALINATION, 2002, 142 (02) : 181 - 186
  • [6] Thermal performance and exergy analysis of a thermal vapor compression desalination system
    Hamed, OA
    Zamamiri, AM
    Aly, S
    Lior, N
    [J]. ENERGY CONVERSION AND MANAGEMENT, 1996, 37 (04) : 379 - 387
  • [7] Exergy analysis of vortex tube expansion vapour compression refrigeration system
    Sarkar, Jahar
    [J]. INTERNATIONAL JOURNAL OF EXERGY, 2013, 13 (04) : 431 - 446
  • [8] Energy/exergy analysis of solar driven mechanical vapor compression desalination system with nano-filtration pretreatment
    Farahat, Mohamed A.
    Fath, Hassan E. S.
    El-Sharkawy, Ibrahim I.
    Ookawara, Shinichi
    Ahmed, Mahmoud
    [J]. DESALINATION, 2021, 509
  • [9] ENERGY AND EXERGY ANALYSIS OF AN ORGANIC RANKINE CYCLE INTEGRATED WITH VAPOUR COMPRESSION REFRIGERATION SYSTEM
    Malwe, Prateek D.
    Gawali, Bajirao S.
    Choudhari, Mahmadrafik S.
    Dhalait, Rustam S.
    Deshmukh, Nandkishor S.
    [J]. ADVANCES AND APPLICATIONS IN MATHEMATICAL SCIENCES, 2021, 20 (10): : 2137 - 2150
  • [10] ENERGY, EXERGY AND SUSTAINABILITY ANALYSIS OF TWO-STAGE VAPOUR COMPRESSION REFRIGERATION SYSTEM
    Chopra, Kapil
    Sahni, V.
    Mishra, R. S.
    [J]. JOURNAL OF THERMAL ENGINEERING, 2015, 1 (04): : 440 - 445