Open source deformable image registration system for treatment planning and recurrence CT scans

被引:0
|
作者
Zukauskaite, Ruta [1 ,2 ]
Brink, Carsten [1 ,3 ]
Hansen, Christian Ronn [3 ,4 ]
Bertelsen, Anders [3 ,4 ]
Johansen, Jorgen [2 ]
Grau, Cai [5 ]
Eriksen, Jesper Grau [2 ]
机构
[1] Univ Southern Denmark, Inst Clin Res, Odense, Denmark
[2] Odense Univ Hosp, Dept Oncol, Sdr Blvd 29, DK-5000 Odense C, Denmark
[3] Odense Univ Hosp, Lab Radiat Phys, Odense, Denmark
[4] Univ Sydney, Inst Med Phys, Sch Phys, Sydney, NSW, Australia
[5] Aarhus Univ Hosp, Dept Oncol, Aarhus, Denmark
关键词
Computed tomography; Validation; elastix; head and neck; ADAPTIVE RADIATION-THERAPY; CONE-BEAM CT; NECK-CANCER; HEAD; VALIDATION; RADIOTHERAPY;
D O I
10.1007/s00066-016-0998-4
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Clinical application of deformable registration (DIR) of medical images remains limited due to sparse validation of DIR methods in specific situations, e. g. in case of cancer recurrences. In this study the accuracy of DIR for registration of planning CT (pCT) and recurrence CT (rCT) images of head and neck squamous cell carcinoma (HNSCC) patients was evaluated. Twenty patients treated with definitive IMRT for HNSCC in 2010-2012 were included. For each patient, a pCT and an rCT scan were used. Median interval between the scans was 8.5 months. One observer manually contoured eight anatomical regions-of-interest (ROI) twice on pCT and once on rCT. pCT and rCT images were deformably registered using the open source software elastix. Mean surface distance (MSD) and Dice similarity coefficient (DSC) between contours were used for validation of DIR. A measure for delineation uncertainty was estimated by assessing MSD from the re-delineations of the same ROI on pCT. DIR and manual contouring uncertainties were correlated with tissue volume and rigidity. MSD varied 1-3 mm for different ROIs for DIR and 1-1.5 mm for re-delineated ROIs performed on pCT. DSC for DIR varied between 0.58 and 0.79 for soft tissues and was 0.79 or higher for bony structures, and correlated with the volumes of ROIs (r = 0.5, p < 0.001) and tissue rigidity (r = 0.54, p < 0.001). DIR using elastix in HNSCC on planning and recurrence CT scans is feasible; an uncertainty of the method is close to the voxel size length of the planning CT images.
引用
收藏
页码:545 / 551
页数:7
相关论文
共 50 条
  • [1] Open source deformable image registration system for treatment planning and recurrence CT scans: Validation in the head and neck region; [Open-Source-System für die deformierbare Bildregistrierung von Planungs- und Rezidiv-CT-Datensätzen: Validierung im Kopf-Hals-Bereich]
    Zukauskaite R.
    Brink C.
    Hansen C.R.
    Bertelsen A.
    Johansen J.
    Grau C.
    Eriksen J.G.
    [J]. Strahlentherapie und Onkologie, 2016, 192 (8) : 545 - 551
  • [2] Evaluation of the Accuracy of Deformable Image Registration On the TomoTherapy Treatment Planning System
    Nakajima, Y.
    Suganami, R.
    Hashimoto, S.
    Ogawa, H.
    Kadoya, N.
    Karasawa, K.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E616 - E617
  • [3] Deep Learning for Rapid Deformable Image Registration of Liver CT Scans
    Anderson, B.
    Cazoulat, G.
    Lin, E.
    Odisio, B.
    Brock, K.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E370 - E371
  • [4] Deformable Image Registration of Diagnostical CT and Planning CT for Breast Conserving Radiotherapy
    Xie, X.
    Yan, H.
    Dai, J.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E599 - E599
  • [5] FINITE ELEMENT BASED DEFORMABLE REGISTRATION OF RADIOTHERAPY PLANNING CT USING TIME OF TREATMENT OPTICAL SURFACE SCANS
    Price, G.
    Parkhurst, J.
    Sharrock, P.
    Whitfield, G.
    Moore, C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S480 - S480
  • [6] Deformable image registration of the treatment planning CT with proton radiographies in perspective of adaptive proton therapy
    Palaniappan, Prasannakumar
    Meyer, Sebastian
    Kamp, Florian
    Belka, Claus
    Riboldi, Marco
    Parodi, Katia
    Gianoli, Chiara
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (04):
  • [7] QA of dose originating from deformable image registration of planning CT to CBCT on the Ethos system
    Sjolin, M.
    Vogelius, I. R.
    Jensen, N. K. G.
    Bak, M. E.
    Kjaer-Kristoffersen, F.
    Nottrup, T. J.
    Friborg, J.
    Hansen, V. N.
    Petersen, J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1427 - S1429
  • [8] Validation of a deformable image registration produced by a commercial treatment planning system in head and neck
    Garcia-Molla, Rafael
    de Marco-Blancas, Noelia
    Bonaque, Jorge
    Vidueira, Laura
    Lopez-Tarjuelo, Juan
    Perez-Calatayud, Jose
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (03): : 219 - 223
  • [9] Evaluation of Synthetic CT Images Generated by Deformable Image Registration of Outdated Planning CT to CBCT of Treatment Day
    Yoon, J.
    Yeo, I.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [10] Validation of a deformable registration image of a commercial treated planning system
    Garcia-Molla, R.
    Marco-Blancas, N.
    Bonaque, J.
    Viduera, L.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S261 - S262