Irreversible membrane fouling in microfiltration membranes filtering coagulated surface water

被引:86
|
作者
Kimura, Katsuki [1 ]
Maeda, Tomohiro [1 ]
Yamamura, Hiroshi [1 ]
Watanabe, Yoshimasa [1 ]
机构
[1] Hokkaido Univ, Div Built Environm, Kita Ku, Sapporo, Hokkaido 0608628, Japan
关键词
membrane filtration; water treatment; membrane fouling; coagulation; particle size;
D O I
10.1016/j.memsci.2008.04.018
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Chemical coagulation has been widely used as a method to mitigate membrane fouling in MF/UF membranes used for drinking water treatment. Optimization of coagulation as pre-treatment of membrane processes has not been achieved yet: the optimum condition of coagulation for conventional treatment systems is not necessarily applicable to membrane-based treatment systems. This study investigated (physically) irreversible membrane fouling in an MF membrane used with pre-coagulation by aluminum salt. In a series of bench-scale filtration tests, feed water containing commercially available humic acid or organic matter isolated from surface water was coagulated with polyaluminum chloride (PACl) under various conditions and subsequently filtered with an MF membrane with the nominal pore size of 0.1 mu m. It was found that coagulation conditions had great impacts on the degree of physically irreversible fouling. Acidic conditions improved the quality of treated water but generally caused greater physically irreversible fouling than did neutral or alkaline conditions. Also, dosage of coagulant was found to be influential on the degree of membrane fouling: high dosage of coagulant frequently caused more severe irreversible fouling. Sizes of flocs seemed to become small under acidic conditions in this study, which was indicated by high concentrations of aluminum in the permeate under acidic conditions. It is thought that small flocs produced under acidic conditions could migrate into micropores of the membrane and caused physically irreversible fouling by plugging or adsorption. These findings obtained in the bench-scale tests were verified in a long-term pilot-scale test. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:356 / 362
页数:7
相关论文
共 50 条
  • [1] Irreversible membrane fouling during ultrafiltration of surface water
    Kimura, K
    Hane, Y
    Watanabe, Y
    Amy, G
    Ohkuma, N
    [J]. WATER RESEARCH, 2004, 38 (14-15) : 3431 - 3441
  • [2] Microfiltration process for surface water treatment: irreversible fouling identification and chemical cleaning
    Liu, Junxia
    Dong, Bingzhi
    Cao, Bangqing
    Zhao, Dongsheng
    Wang, Zhihong
    [J]. RSC ADVANCES, 2016, 6 (115) : 114005 - 114013
  • [3] Influence of calcium on the evolution of irreversible fouling in microfiltration/ultrafiltration membranes
    Yamamura, Hiroshi
    Okimoto, Kenji
    Kimura, Katsuki
    Watanabe, Yoshimasa
    [J]. JOURNAL OF WATER SUPPLY RESEARCH AND TECHNOLOGY-AQUA, 2007, 56 (6-7): : 425 - 434
  • [4] Reversible and irreversible membrane fouling in hollow-fiber UF membranes filtering surface water: effects of ozone/powdered activated carbon treatment
    Huang, Weiwei
    Zhu, Yuanhong
    Wang, Lin
    Lv, Weiguang
    Dong, Bingzhi
    Zhou, Wenzong
    [J]. RSC ADVANCES, 2021, 11 (17) : 10323 - 10335
  • [5] Fouling of microfiltration membranes by the fractional components of natural organic matter in surface water
    Fan, L
    Harris, J
    Roddick, F
    Booker, N
    [J]. 3RD WORLD WATER CONGRESS: DRINKING WATER TREATMENT, 2002, 2 (5-6): : 313 - 320
  • [6] Mechanism involved in the evolution of physically irreversible fouling in microfiltration and ultrafiltration membranes used for drinking water treatment
    Yamamura, Hiroshi
    Kimura, Katsuki
    Watanabe, Yoshimasa
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2007, 41 (19) : 6789 - 6794
  • [7] Mechanisms of Physically Irreversible Fouling during Surface Water Microfiltration and Mitigation by Aluminum Electroflotation Pretreatment
    Gamage, Neranga P.
    Chellam, Shankararaman
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2014, 48 (02) : 1148 - 1157
  • [8] The influence of surface forces on the fouling of polypropylene microfiltration membranes
    Department of Chemistry, Australian National University, Canberra, ACT, Australia
    [J]. COLLOIDS SURF. A PHYSICOCHEM. ENG. ASP, 1 (63-81):
  • [9] The influence of surface forces on the fouling of polypropylene microfiltration membranes
    Meagher, L
    Klauber, C
    Pashley, RM
    [J]. COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 1996, 106 (01) : 63 - 81
  • [10] Transition in fouling mechanism in microfiltration of a surface water
    Yamamura, Hiroshi
    Chae, Soryong
    Kimura, Katsuki
    Watanabe, Yoshimasa
    [J]. WATER RESEARCH, 2007, 41 (17) : 3812 - 3822