Mid-term results for second-generation thoracic stent grafts

被引:55
|
作者
Bell, RE
Taylor, PR
Aukett, M
Sabharwal, T
Reidy, JF
机构
[1] Guys & St Thomas Hosp, Dept Gen & Vasc Surg, London SE1 7EH, England
[2] Guys & St Thomas Hosp, Dept Radiol, London SE1 7EH, England
关键词
D O I
10.1002/bjs.4178
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Thoracic stent grafts offer an alternative to open surgery for thoracic aortic disease, but their long-term durability is unknown. This report includes mid-term follow-up for commercially available thoracic devices. Methods: Data were collected prospectively for a series of endoluminal grafts used to treat thoracic aortic pathology. Results: Between July 1997 and October 2002, 67 patients received thoracic stent grafts. Elective procedures incurred a 30-day mortality rate of 2 per cent (one of 42 patients) and urgent repair 16 per cent (four of 25). Paraplegia affected three (4 per cent) of 67 patients and three patients had a stroke. The median follow-up was 17 (range 2-64) months; four patients were lost. There were six late deaths, two from aneurysm rupture (rupture of a mycotic aneurysm at 5 months and stent migration at 28 months). Other device-related complications comprised three proximal endoleaks, one of which required open surgical correction with removal of the stent graft, and two distal endoleaks, which were successfully treated with distal extension cuffs. Conclusion: In the mid term, endoluminal repair of thoracic aortic pathology appears to be a safe alternative to open surgery, but continued surveillance is essential.
引用
收藏
页码:811 / 817
页数:7
相关论文
共 50 条
  • [1] Thoracic stent grafts: mid-term results for commercial devices
    Bell, RE
    Aukett, M
    Reidy, JF
    Taylor, PR
    BRITISH JOURNAL OF SURGERY, 2003, 90 (04) : 509 - 509
  • [2] Chronic traumatic aneurysms of the descending thoracic aorta: mid-term results of endovascular repair using first and second-generation stent-grafts
    Demers, P
    Miller, C
    Mitchell, RS
    Kee, ST
    Chagonjian, RNL
    Dake, MD
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2004, 25 (03) : 394 - 400
  • [3] Endovascular implantation of stent-grafts in the thoracic aorta mid-term results of a prospective controlled study
    Duda, SH
    Pusich, B
    Raygrotzki, S
    Uckmann, FP
    Aebert, H
    Tepe, G
    Pereira, P
    Feuls, R
    Ziemer, G
    Claussen, CD
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (04): : 485 - 489
  • [4] Thoracic endovascular aortic repair with homemade stent grafts: Early and mid-term outcomes
    Seiji Onitsuka
    Atsuhisa Tanaka
    Hidetoshi Akashi
    Keiichi Akaiwa
    Keita Mikasa
    Kurando Kanaya
    Yusuke Shintani
    Shinichi Hiromatsu
    Shigeaki Aoyagi
    Surgery Today, 2011, 41 : 1054 - 1061
  • [5] Thoracic Endovascular Aortic Repair with Homemade Stent Grafts: Early and Mid-Term Outcomes
    Onitsuka, Seiji
    Tanaka, Atsuhisa
    Akashi, Hidetoshi
    Akaiwa, Keiichi
    Mikasa, Keita
    Kanaya, Kurando
    Shintani, Yusuke
    Hiromatsu, Shinichi
    Aoyagi, Shigeaki
    SURGERY TODAY, 2011, 41 (08) : 1054 - 1061
  • [6] French registry of coronary stent grafts. Acute and mid-term results
    Morice, MC
    Louvard, Y
    Maillard, L
    Guermonprez, JL
    Khalife, K
    Druelles, P
    Chevalier, B
    Hirsch, JL
    Wittenberg, O
    Boccara, A
    Valeix, B
    Cribier, A
    CIRCULATION, 1998, 98 (17) : 855 - 855
  • [7] Embolization of intracranial aneurysms with second-generation Matrix-2 detachable coils: mid-term and long-term results
    Ansari, Sameer A.
    Dueweke, Eric J.
    Kanaan, Yassine
    Chaudhary, Neeraj
    Gandhi, Dheeraj
    Thompson, B. Gregory
    Gemmete, Joseph J.
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2011, 3 (04) : 324 - 330
  • [8] Mid-Term Clinical Outcomes and Survivorship of a Second-Generation Modular Revision Knee System
    Kolich, Mark T.
    Adams, Joanne B.
    Morris, Michael J.
    Hurst, Jason M.
    Berend, Keith R.
    Lombardi, Adolph V., Jr.
    Crawford, David A.
    SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2021, 38
  • [9] TAArget versus EndoFit thoracic stent-grafts in thoracic endovascular aortic repair: a retrospective comparison of early and mid-term results in a single center
    Wu, Ziheng
    Qu, Lefeng
    Zhi, Kangkang
    Zhang, Hondkun
    Raithel, Dieter
    JOURNAL OF CARDIOVASCULAR SURGERY, 2016, 57 (03): : 466 - 473
  • [10] Comparison of Mid-term angiographic outcomes of second generation drug-eluting-stent
    Murase, S.
    Matsuda, O.
    Murata, A.
    Suzuki, Y.
    Ehara, M.
    Ito, T.
    EUROPEAN HEART JOURNAL, 2013, 34 : 547 - 547