Contact Lens Characteristics and Contrast Sensitivity of Patients With Keratoconus

被引:16
|
作者
Wei, Rui Hua [1 ,2 ]
Khor, Wei-Boon [1 ]
Lim, Li [1 ]
Tan, Donald T. H. [1 ]
机构
[1] Singapore Natl Eye Ctr, Dept Cornea & External Eye Dis, Singapore 168751, Singapore
[2] Tianjin Med Univ, Ctr Eye, Dept Cornea & External Eye Dis, Tianjin, Peoples R China
来源
关键词
Keratoconus; Contact lens; Contrast sensitivity; Cornea; Rigid gas permeable; KERATOPLASTY; ACUITY;
D O I
10.1097/ICL.0b013e3182254e7d
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objectives: The aim was to describe the contact lens characteristics and contrast sensitivity of patients with keratoconus managed conservatively with contacts lenses at a tertiary eye center in Singapore. Methods: A prospective cross-sectional study of 116 patients with clinically evident or suspected keratoconus (on videokeratography) recruited over 11 months. Demographic and medical details, visual acuity (VA) and refraction, corneal topography and contact lens characteristics were documented. Contrast sensitivity with contact lenses was performed with the Vision Contrast Test System 6500 under standardized conditions. Results: Overall, 67% of the study patients were wearing contact lenses. Of the 129 eligible eyes analyzed, there were 108 eyes with keratoconus and 21 eyes with keratoconus suspect, and 94% were fitted with rigid gas permeable (RGP) lenses. Proprietary keratoconus design lenses were fitted in 74.9% of keratoconus eyes and 30.0% of suspect eyes. With contact lens wear, 83.3% of keratoconus eyes and 100% of suspect eyes achieved 0.3 vision. Mean contrast sensitivity curves of eyes with keratoconus and keratoconus suspect were found to be within normal, although contrast sensitivity in the keratoconus group was consistently lower. Conclusions: Most of our patients were managed conservatively with contact lenses, and keratoconus design RGP lenses were the most common type fitted. Good VA can be achieved, but patients with keratoconus may still experience a reduction in contrast sensitivity.
引用
收藏
页码:307 / 311
页数:5
相关论文
共 50 条
  • [1] EFFECT OF CONTACT-LENS CORRECTION ON SINE WAVE CONTRAST SENSITIVITY IN KERATOCONUS PATIENTS AFTER PENETRATING KERATOPLASTY
    WICKER, D
    SANISLO, S
    GREEN, DG
    [J]. OPTOMETRY AND VISION SCIENCE, 1992, 69 (05) : 342 - 346
  • [2] Contact lens care and disease characteristics in keratoconus
    Hsiao, John Ching-Jen
    Chen, Shyan-Tarng
    [J]. LIFE SCIENCE JOURNAL-ACTA ZHENGZHOU UNIVERSITY OVERSEAS EDITION, 2013, 10 (01): : 285 - 287
  • [3] Characteristics of 244 patients with keratoconus seen in an optometric contact lens practice
    Shneor, Einat
    Millodot, Michel
    Blumberg, Sharon
    Ortenberg, Ilya
    Behrman, Shmuel
    Gordon-Shaag, Ariela
    [J]. CLINICAL AND EXPERIMENTAL OPTOMETRY, 2013, 96 (02) : 219 - 224
  • [4] Contact lens in keratoconus
    Rathi, Varsha M.
    Mandathara, Preeji S.
    Dumpati, Srikanth
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2013, 61 (08) : 410 - 415
  • [5] Characteristics and functional outcomes of 130 patients with keratoconus attending a specialist contact lens clinic
    N Lim
    U Vogt
    [J]. Eye, 2002, 16 : 54 - 59
  • [6] Characteristics and functional outcomes of 130 patients with keratoconus attending a specialist contact lens clinic
    Lim, N
    Vogt, U
    [J]. EYE, 2002, 16 (01) : 54 - 59
  • [7] Contact Lens Related Quality of Life in Patients With Keratoconus
    Erdurmus, Mesut
    Yildiz, Elvin H.
    Abdalla, Yasmine F.
    Hammersmith, Kristin M.
    Rapuano, Christopher J.
    Cohen, Elisabeth J.
    [J]. EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2009, 35 (03): : 123 - 127
  • [8] Comparison of contrast sensitivity in myopic patients using spectacle and contact lens correction
    Qayyum, Sadaf
    Wahab, Zubair
    Saeed, Rabia
    Zulfiqar, Anbar
    Shakeel, Ayisha
    Iqbal, Iqra
    [J]. PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2021, 15 (05): : 951 - 953
  • [9] Contact lens management of keratoconus
    Downie, Laura E.
    Lindsay, Richard G.
    [J]. CLINICAL AND EXPERIMENTAL OPTOMETRY, 2015, 98 (04) : 299 - 311
  • [10] CONTRAST SENSITIVITY WITH CONTACT-LENS CORRECTIONS FOR PRESBYOPIA
    COLLINS, MJ
    BROWN, B
    BOWMAN, KJ
    [J]. OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1989, 9 (02) : 133 - 138