Segmentation of diabetic macular edema for retinal OCT images

被引:0
|
作者
Chen, Minghui [1 ,2 ,3 ]
He, Jintao [1 ]
Jia, Wenyu [1 ]
Qin, Xianfu [1 ]
Chen, Zhongping [2 ,3 ]
机构
[1] Univ Shanghai Sci & Technol, Shanghai Inst Minimally Invas Therapy, Inst Biomed Opt & Optometry, 516 Jungong Rd, Shanghai 200093, Peoples R China
[2] Univ Calif Irvine, Beckman Laser Inst, Irvine, CA 92612 USA
[3] Univ Calif Irvine, Ctr Biomed Engn, Irvine, CA 92612 USA
关键词
optical coherence tomography (OCT); diabetic macular edema(DME); level set; segmentation; OPTICAL COHERENCE TOMOGRAPHY; DEGENERATION;
D O I
10.1117/12.2500684
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Optical coherence tomography (OCT) is becoming one of the most important detection modalities for fast and noninvasive assessment of ophthalmological diseases. Diabetic macular edema (DME) is one of the important reasons leads to blindness. Its pathological features are mainly manifested in the accumulation of fluid in the retina. An automated method is proposed to identify and quantify the volume of cystoid macular edema in Spectral Domain OCT (SD-OCT) images. In the first stage of preprocessing, we balance the apparent signal-to-noise of each retinal OCT image. Because the signal-to-noise of OCT images is variable from patient to patient, and balance of the signal-to-noise ensures consistent segmentation of cystoid fluid. Speckle noise is the main reason leads to quality degrading in OCT images. The denoising method should be efficient for the noise suppression, and the edge information can be preserved at the same time. Then we used the anisotropic diffusion filter to suppress shot noise. The intensity inhomogeneity in OCT images may lead to false detection in the further segmentation work. Then we used the gamma transformation to change the brightness, which eliminates the effect availably. In the second stage of segmentation, we solve the problem of segmentation effectively by the improved level set method and calculated the area of edema area, which provides quantitative analytic tools for clinical diagnosis and therapy. Finally, the proposed method was evaluated on 15 SD-OCT retinal images from DME adults. Leave-one-out evaluation resulted in a precision, sensitivity and dice similarity coefficient (DSC) of 81.12%, 86.90% and 80.05%, respectively.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Joint Diabetic Macular Edema Segmentation and Characterization in OCT Images
    Joaquim de Moura
    Gabriela Samagaio
    Jorge Novo
    Pablo Almuina
    María Isabel Fernández
    Marcos Ortega
    [J]. Journal of Digital Imaging, 2020, 33 : 1335 - 1351
  • [2] Joint Diabetic Macular Edema Segmentation and Characterization in OCT Images
    de Moura, Joaquim
    Samagaio, Gabriela
    Novo, Jorge
    Almuina, Pablo
    Fernandez, Maria Isabel
    Ortega, Marcos
    [J]. JOURNAL OF DIGITAL IMAGING, 2020, 33 (05) : 1335 - 1351
  • [3] Development of a Semi-Automatic Segmentation Method for Retinal OCT Images Tested in Patients with Diabetic Macular Edema
    Huang, Yijun
    Danis, Ronald P.
    Pak, Jeong W.
    Luo, Shiyu
    White, James
    Zhang, Xian
    Narkar, Ashwini
    Domalpally, Amitha
    [J]. PLOS ONE, 2013, 8 (12):
  • [4] Graph-Based Segmentation for Diabetic Macular Edema Selection in OCT Images
    Ilyasova, Nataly
    Shirokanev, Alexander
    Demin, Nikita
    Paringer, Rustam
    [J]. 2019 5TH INTERNATIONAL CONFERENCE ON FRONTIERS OF SIGNAL PROCESSING (ICFSP 2019), 2019, : 77 - 81
  • [5] Impact of Data Augmentation on Retinal OCT Image Segmentation for Diabetic Macular Edema Analysis
    Bar-David, Daniel
    Bar-David, Laura
    Soudry, Shiri
    Fischer, Anath
    [J]. OPHTHALMIC MEDICAL IMAGE ANALYSIS, OMIA 2021, 2021, 12970 : 148 - 158
  • [6] Computer aided diagnosis of diabetic macular edema in retinal fundus and OCT images: A review
    Pavithra, K. C.
    Kumar, Preetham
    Geetha, M.
    Bhandary, Sulatha V.
    [J]. BIOCYBERNETICS AND BIOMEDICAL ENGINEERING, 2023, 43 (01) : 157 - 188
  • [7] Automated Segmentation Of Intraretinal Cystoid Macular Edema For Retinal 3D OCT Images With Macular Hole
    Zhang, Li
    Zhu, Weifang
    Shi, Fei
    Chen, Haoyu
    Chen, Xinjian
    [J]. 2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI), 2015, : 1494 - 1497
  • [8] Automatic Segmentation of Macular Edema in Retinal OCT Images Using Improved U-Net plus
    Gao, Zhijun
    Wang, Xingle
    Li, Yi
    [J]. APPLIED SCIENCES-BASEL, 2020, 10 (16):
  • [9] Multiscale Unsupervised Retinal Edema Area Segmentation in OCT Images
    Yuan, Wenguang
    Lu, Donghuan
    Wei, Dong
    Ning, Munan
    Zheng, Yefeng
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION, MICCAI 2022, PT II, 2022, 13432 : 667 - 676
  • [10] Research on Semantic Segmentation Method of Macular Edema in Retinal OCT Images Based on Improved Swin-Unet
    Gao, Zhijun
    Chen, Lun
    [J]. ELECTRONICS, 2022, 11 (15)