Crestal bone changes around titanium implants: A methodologic study comparing linear radiographic with histometric measurements

被引:0
|
作者
Hermann, JS
Schoolfield, JD
Nummikoski, PV
Buser, D
Schenk, RK
Cochran, DL
机构
[1] Univ Texas, Hlth Sci Ctr, Sch Dent, Dept Periodont, San Antonio, TX 78284 USA
[2] Univ Zurich, Sch Dent, Div Periodont, Dept Prevent Dent Periodont & Cariol, Zurich, Switzerland
[3] Univ Texas, Hlth Sci Ctr, Dept Dent Diagnost Sci, San Antonio, TX 78284 USA
[4] Univ Bern, Sch Dent Med, Dept Oral Surg, Bern, Switzerland
关键词
animal study; crestal bone loss; endosseous implants; histometry; standardized radiography;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Generally, endosseous implants can be placed according to a nonsubmerged or a submerged technique and in 1-piece or 2-piece configurations. Recently, it has been shown that peri-implant crestal bone reactions differ significantly radiographically as well as histometrically under such conditions and are dependent on a rough/smooth implant border in 1-piece implants and on the location of a microgap (interface) between the implant and the abutment/restoration in 2-piece configurations. The purpose of this study was to evaluate whether standardized radiography as a noninvasive clinical diagnostic method correlates with peri-implant crestal bone levels as determined by histometric analysis. Fifty-nine implants were placed in edentulous mandibular areas of 5 foxhounds in a side-by-side comparison in both submerged and nonsubmerged techniques. Three months after implant placement, abutment connection was performed in the submerged implant sites. At 6 months, all animals were sacrificed, and evaluations of the first bone-to-implant contact (fBIC), determined on standardized periapical radiographs, were compared to similar analyses made from nondecalcified histology. it was shown that both techniques provide the same information (Pearson correlation coefficient = 0.993; P <.001). The precision of the radiographs was within 0.1 mm of the histometry in 73.4% of the evaluations, while the level of agreement fell to between 0.1 and 0.2 mm in 15.9% of the cases. These data demonstrate in an experimental study that standardized periapical radiography can evaluate crestal bone levels around implants clinically accurately (within 0.2 mm) in a high percentage (89%) of cases. These findings are significant because crestal bone levels can be determined using a noninvasive technique, and block sectioning or sacrifice of the animal subject is not required. In addition, longitudinal evaluations can be made accurately such that bone changes over various time periods can be assessed. Such analyses may prove beneficial when trying to distinguish physiologic changes from pathologic changes or when trying to determine causes and effects of bone changes around dental implants.
引用
收藏
页码:475 / 485
页数:11
相关论文
共 50 条
  • [1] Influence of a Machined Collar on Crestal Bone Changes Around Titanium Implants: A Histometric Study in the Canine Mandible
    Hermann, Joachim S.
    Jones, Archie A.
    Bakaeen, Lara G.
    Buser, Daniel
    Schoolfield, John D.
    Cochran, David L.
    [J]. JOURNAL OF PERIODONTOLOGY, 2011, 82 (09) : 1329 - 1338
  • [2] Crestal bone response to loaded zirconia and titanium implants: a radiographic and histometric analysis in canines
    Corinne E. Oeschger
    Dieter D. Bosshardt
    Stefan Roehling
    Michael Gahlert
    David L. Cochran
    Simone F. M. Janner
    [J]. Clinical Oral Investigations, 2020, 24 : 3609 - 3617
  • [3] Crestal bone response to loaded zirconia and titanium implants: a radiographic and histometric analysis in canines
    Oeschger, Corinne E.
    Bosshardt, Dieter D.
    Roehling, Stefan
    Gahlert, Michael
    Cochran, David L.
    Janner, Simone F. M.
    [J]. CLINICAL ORAL INVESTIGATIONS, 2020, 24 (10) : 3609 - 3617
  • [4] RADIOGRAPHIC STUDY OF CRESTAL BONE CHANGES AROUND NON-SUBMERGED DENTAL IMPLANTS
    PHAM, A
    WEBER, H
    FIORELLINI, J
    PAQUETTE, D
    WILLIAMS, R
    [J]. JOURNAL OF DENTAL RESEARCH, 1994, 73 : 399 - 399
  • [5] Crestal bone changes around titanium implants. A histometric evaluation of unloaded non-submerged and submerged implants in the canine mandible
    Hermann, JS
    Buser, D
    Schenk, RK
    Cochran, DL
    [J]. JOURNAL OF PERIODONTOLOGY, 2000, 71 (09) : 1412 - 1424
  • [6] Crestal bone changes around titanium implants. A radiographic evaluation of unloaded nonsubmerged and submerged implants in the canine mandible
    Hermann, JS
    Cochran, DL
    Nummikoski, PV
    Buser, D
    [J]. JOURNAL OF PERIODONTOLOGY, 1997, 68 (11) : 1117 - 1130
  • [7] Influence of the size of the microgap on crestal bone changes around titanium implants. A histometric evaluation of unloaded non-submerged implants in the canine mandible
    Hermann, JS
    Schoolfield, JD
    Schenk, RK
    Buser, D
    Cochran, DL
    [J]. JOURNAL OF PERIODONTOLOGY, 2001, 72 (10) : 1372 - 1383
  • [8] Cyclosporine-a and bone density around titanium implants: a histometric study in rabbits
    Sakakura, Celso Eduardo
    Valerio Lopes, Beatriz Maria
    Margonar, Rogerio
    Queiroz, Thallita Pereira
    Nociti Junior, Francisco Humberto
    Marcantonio Junior, Elcio
    [J]. JOURNAL OF OSSEOINTEGRATION, 2011, 3 (02) : 25 - 29
  • [9] A Prospective Multicenter Study on Radiographic Crestal Bone Changes Around Dental Implants Placed at Crestal or Subcrestal Level: One-Year Findings
    Gatti, Claudio
    Gatti, Fulvio
    Silvestri, Maurizio
    Mintrone, Francesco
    Rossi, Roberto
    Tridondani, Gabriele
    Piacentini, Giacomo
    Borrelli, Paola
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (04) : 913 - 918
  • [10] Changes in Crestal Bone Around Endosseous Implants During Functional Loading: A Radiographic Evaluation in Edentulous Patients Comparing Different Implant Designs
    Tymstra, Nynke
    Meijer, Henny J. A.
    Raghoebar, Gerry M.
    Vissink, Arjan
    [J]. INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2012, 32 (06) : 677 - 686