New polymer gel dosimeter with high refractive index for artifact-free optical CT scanning

被引:0
|
作者
Maryanski, M [1 ]
机构
[1] MGS Res Inc, Madison, CT USA
关键词
D O I
10.1118/1.1997937
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In order to enable optical CT scanning of gels with inserts representing tissue heterogeneities such as bone or air spaces as well as brachytherapy catheters and applicators, as well as to remove artifacts which arise when scanning across regions adjacent to container walls, we have explored the feasibility of developing a new polymer gel that would result in matching the refractive index of the gel to that of the container material. Method and Material: We have developed a new type of polymer gel dosimeter (and named it BANG4), based on cellulose acetate (gelling agent) in benzyl alcohol. The monomer we used in this study was methacrylic acid, which precipitates in benzyl alcohol upon polymerization. The gel is made under nitrogen atmosphere. These gels are optically clear and mechanically strong. Benzyl alcohol has the refractive index of 1.538 and methacrylic acid 1.429. Therefore, we can adjust the refractive index of the gel to match the material of the container (phantom) or insert, be it Lucite, PVC, PETG, Barex or glass. We have tested the dose response of the new gel using Torrex 150D X ray machine (EG&G, Long Beach, CA) and a spectrophotometer. We also scanned irradiated BANG4 gels in Barex and Lucite containers, using commercial OCTOPUS™ optical CT scanner (MGS Research, Madison, CT). Results: We found the dose response of the new gel to be linear up to 6 Gy. The optical CT images of BANG4 gels reveal that the refractive artifact was entirely removed, as can be seen from image profiles. Conclusion: We have successfully demonstrated the feasibility of a new class of polymer gels that can be OCT‐scanned without the refractive artifact. Further studies are planned to investigate radiological properties of the new dosimeter. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1998 / 1998
页数:1
相关论文
共 50 条
  • [1] Effects of refractive index mismatch in optical CT imaging of polymer gel dosimeters
    Manjappa, Rakesh
    Makki, Sharath S.
    Kumar, Rajesh
    Kanhirodan, Rajan
    MEDICAL PHYSICS, 2015, 42 (02) : 750 - 759
  • [2] New optical scanning microscope for refractive index profiles measurement
    Loffredo, A.
    Journal of Optical Communications, 1988, 9 (03) : 88 - 91
  • [3] PbS/polymer nanocomposite optical materials with high refractive index
    Lü, CL
    Guan, C
    Liu, YF
    Cheng, YR
    Yang, B
    CHEMISTRY OF MATERIALS, 2005, 17 (09) : 2448 - 2454
  • [4] An investigation comparing optical CT with MR scanning for polymer gel dosimetry
    Oldham, M
    Siewerdsen, JH
    Shetty, A
    Jaffray, DA
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 1165 - 1171
  • [5] New X-CT Dose Calibration Method Using Polymer Gel Dosimeter
    Ota, J.
    Kurosawa, R.
    Kobayashi, T.
    Yoshitada, M.
    Chida, K.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [6] 3-D dosimetry with optical CT scanning of polymer gels and radiochromic plastic dosimeter
    Wuu, Cheng-Shie
    Xu, Y.
    RADIATION MEASUREMENTS, 2011, 46 (12) : 1903 - 1907
  • [7] Sensitivity calibration procedures in optical-CT scanning of polymer gel dosimeters
    Xu, Y
    Wuu, C
    Maryanski, M
    MEDICAL PHYSICS, 2004, 31 (06) : 1833 - 1833
  • [8] New PFAS-free optical adhesive with high heat resistance and low refractive index
    Kajiwara, Masashi
    Yamada, Yoshito
    Yamaguchi, Takashi
    Sakai, Noriyuki
    2024 13TH IEEE CPMT SYMPOSIUM JAPAN, ICSJ 2024, 2024, : 102 - 105
  • [9] Accuracy of high-resolution optical CT scanning system for polymer gel dosimetry as applied to intravascular brachytherapy
    Liang, R
    Wuu, C
    Maryanski, M
    MEDICAL PHYSICS, 2002, 29 (06) : 1206 - 1206
  • [10] High Quality and Artifact-Free 4D Cone Beam CT and Its Application in Adaptive Treatment Planning
    Niu, K.
    Li, K.
    Smilowitz, J.
    Chen, G.
    MEDICAL PHYSICS, 2014, 41 (06) : 574 - 574