Multi-residue analysis of selected pharmaceuticals in wastewater samples by stir-bar sorptive extraction followed by liquid desorption and liquid chromatography-mass spectrometry

被引:1
|
作者
Klancar, A. [1 ]
Zakotnik, M. [1 ]
Roskar, R. [1 ]
Trontelj, J. [1 ]
机构
[1] Univ Ljubljana, Fac Pharm, Dept Biopharmaceut & Pharmacokinet, Askerceva 7, Ljubljana 1000, Slovenia
关键词
PERSONAL CARE PRODUCTS; STEROID SEX-HORMONES; THERMAL-DESORPTION; EMERGING CONTAMINANTS; ORGANIC CONTAMINANTS; ENVIRONMENTAL WATERS; AQUATIC ENVIRONMENT; POLAR; ESTROGENS; OPTIMIZATION;
D O I
10.1039/c7ay01310h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
New organic pollutants such as pharmaceuticals have been recently classified as emerging pollutants. These are chemically active compounds and may pose a risk to environmental organisms as well as to humans. Nowadays, separation and analytical techniques enable detection and quantification at extremely low concentrations. We aimed to develop and optimise a new method that would minimise (organic) solvent consumption and miniaturise and simplify sample preparation through the use of stirbar sorptive extraction of selected pharmaceuticals, followed by liquid desorption and liquid chromatography coupled to mass spectrometry. Several conditions and parameters that affect the extraction procedure (extraction time, sample pH, sample volume, extraction temperature, and addition of salt and organic modifier) were evaluated for suitable extraction efficiency. The optimised method (sample volume, 20 mL; sample pH, 9; extraction time, 150 min; and desorption time, 15 min; in an acetonitrile and methanol [50 : 50 v/v] mixture at 50 degrees C, without any added modifier) was validated and provided recoveries above 80% for 12 analytes, and for 6 analytes they were between 45% and 65%, while for another 6 analytes the recoveries were below 25%. The method provided a wide linear range (mainly 1.25-1250 ng L-1, R-2 > 0.99) with very low limits of quantification for all analytes (1.25-5.0 ng L-1). The method was used to test 15 wastewater samples and 22 out of 24 monitored pharmaceuticals were detected, generally in concentrations below 200 ng L-1.
引用
收藏
页码:5310 / 5321
页数:12
相关论文
共 50 条
  • [1] Multi-residue screening of endocrine disrupters chemicals in water samples by stir bar sorptive extraction-liquid desorption-capillary gas chromatography-mass spectrometry detection
    Serôdio, P
    Nogueira, JMF
    [J]. ANALYTICA CHIMICA ACTA, 2004, 517 (1-2) : 21 - 32
  • [2] Multiresidue analysis of acidic and polar organic contaminants in water samples by stir-bar sorptive extraction-liquid desorption-gas chromatography-mass spectrometry
    Quintana, Jose Benito
    Rodil, Rosario
    Muniategui-Lorenzo, Soledad
    Lopez-Mahia, Purificacion
    Prada-Rodriguez, Dario
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1174 (1-2) : 27 - 39
  • [3] Application of stir-bar sorptive extraction with liquid desorption to the determination of chlorinated hydrocarbons in water samples
    Wejnerowska, Grazyna
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2022, 102 (02) : 589 - 601
  • [4] Multi-residue off-flavour profiling in wine using stir bar sorptive extraction-thermal desorption-gas chromatography-mass spectrometry
    Franc, Celine
    David, Frank
    de Revel, Gilles
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (15) : 3318 - 3327
  • [5] Quantitative determination of triclocarban in wastewater effluent by stir bar sorptive extraction and liquid desorption-liquid chromatography-tandem mass spectrometry
    Klein, Dustin R.
    Flannelly, David F.
    Schultz, Melissa M.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (11) : 1742 - 1747
  • [6] Multi-residue analysis of avermectins in swine liver by immunoaffinity extraction and liquid chromatography-mass spectrometry
    Wu, ZG
    Li, JS
    Zhu, L
    Luo, HP
    Xu, XJ
    [J]. JOURNAL OF CHROMATOGRAPHY B, 2001, 755 (1-2): : 361 - 366
  • [7] Multi-residue screening of pesticides in vegetables, fruits and baby food by stir bar sorptive extraction-thermal desorption-capillary gas chromatography-mass spectrometry
    Sandra, P
    Tienpont, B
    David, F
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2003, 1000 (1-2) : 299 - 309
  • [8] Matrix effects in pesticide multi-residue analysis by liquid chromatography-mass spectrometry
    Kruve, Anneli
    Kuennapas, Allan
    Herodes, Koit
    Leito, Ivo
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2008, 1187 (1-2) : 58 - 66
  • [9] Stir bar sorptive extraction and trace analysis of selected endocrine disruptors in water, biosolids and sludge samples by thermal desorption with gas chromatography-mass spectrometry
    Tan, Benjamin L. L.
    Hawker, Darryl W.
    Mueller, Jochen F.
    Tremblay, Louis A.
    Chapman, Heather F.
    [J]. WATER RESEARCH, 2008, 42 (1-2) : 404 - 412
  • [10] Development of stir-bar sorptive extraction-thermal desorption-gas chromatography-mass spectrometry for the analysis of musks in vegetables and amended soils
    Aguirre, Josu
    Bizkarguenaga, Ekhine
    Iparraguirre, Arantza
    Angel Fernandez, Luis
    Zuloaga, Olatz
    Prieto, Ailette
    [J]. ANALYTICA CHIMICA ACTA, 2014, 812 : 74 - 82