Influence of Screw Design, Sex, and Approach in Scaphoid Fracture Fixation

被引:15
|
作者
Meermans, Geert [1 ]
Verstreken, Frederik [2 ]
机构
[1] Lievensberg Hosp, Bergen Op Zoom, Netherlands
[2] Monica Hosp, Deurne, Belgium
关键词
HERBERT SCREW; CAST IMMOBILIZATION; INTERNAL-FIXATION; WAIST FRACTURES; DORSAL APPROACH; PLACEMENT; EPIDEMIOLOGY; AGREEMENT; INSERTION; NONUNION;
D O I
10.1007/s11999-011-2218-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Screw fixation of scaphoid fractures has gained popularity. A long central screw has been shown to be biomechanically advantageous. We compared the ability of different screw designs to obtain this goal and determined the influence of sex and approach on screw length. We performed all measurements on three-dimensional reconstructions of 20 CT scans of normal scaphoids (10 men and 10 women) with the use of software. The three-dimensional computer models were analyzed, the central axis was defined, and the screws were placed along this axis. We compared 15 different available screw designs and volar and dorsal screw placement. The length of the scaphoid along its central axis was longer in men (mean, 27.14 mm; standard error of the mean, 0.97 mm) than in women (mean, 23.86 mm; standard error of the mean, 0.37 mm). The screw length that can be used was longer in the volar approach (mean, 23.72 mm; standard error of the mean, 0.19 mm) than in the dorsal approach (mean, 23.31 mm; standard error of the mean, 0.19 mm) regardless of the screw design. Screws with a trailing thread diameter greater than 3.9 mm and leading thread diameter greater than 3.0 mm were shorter. Scaphoids in women are smaller than in men. Theoretically, fixation of scaphoid fractures through a volar approach will allow the surgeon to use longer screws. The screw design has a significant influence on the screw length that can be used in scaphoid fracture fixation. We recommend using a differential pitch screw with a thread diameter of 3.9 mm or less.
引用
收藏
页码:1673 / 1681
页数:9
相关论文
共 50 条
  • [1] Screw fixation for scaphoid fracture: A comparision of volar and dorsal approach
    Fujitani, R.
    Omokawa, S.
    Dohi, Y.
    Ono, H.
    Furuta, K.
    PROCEEDINGS OF THE 10TH CONGRESS OF THE INTERNATIONAL FEDERATION OF SOCIETIES FOR SURGERY OF THE HAND & 7TH CONGRESS OF THE INTERNATIONAL FEDERATION OF SOCIETIES FOR HAND THERAPY, 2007, : 183 - +
  • [2] A simplified approach for unstable scaphoid fracture fixation using the acutrak screw
    Chung, KC
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2002, 110 (07) : 1697 - 1703
  • [3] Screw Fixation Alone for Scaphoid Fracture Nonunion
    Ernst, Stephen Michael Crowe
    Green, David P.
    Saucedo, James M.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2018, 43 (09): : 837 - 843
  • [4] INDICATIONS OF PERCUTANEOUS SCREW FIXATION IN SCAPHOID FRACTURE
    WOZASEK, GE
    MOSER, KD
    UNFALLCHIRURG, 1991, 94 (07): : 342 - 345
  • [5] Trans-scaphoid perilunate fracture dislocations: Results of screw fixation of the scaphoid and lunotriquetral repair with a dorsal approach
    Knoll, VD
    Allan, C
    Trumble, TE
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2005, 30A (06): : 1145 - 1152
  • [6] Scaphoid Proximal Pole Fracture Following Headless Screw Fixation
    Rancy, Schneider K.
    Zelken, Jonathan A.
    Lipman, Joseph D.
    Wolfe, Scott W.
    JOURNAL OF WRIST SURGERY, 2016, 5 (01) : 71 - 76
  • [7] The Headless Compression Screw - Technical challenges in scaphoid fracture fixation
    Ahmed, Usman
    Malik, Shahbaz
    David, Michael
    Simpson, Claire
    Tan, Simon
    Power, Dominic
    JOURNAL OF ORTHOPAEDICS, 2015, 12 : S211 - S216
  • [8] Percutaneous cannulated screw fixation of acute scaphoid waist fracture
    Yip, HSF
    Wu, WC
    Chang, RYP
    So, TYC
    JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2002, 27B (01): : 42 - 46
  • [9] Modified Fluoroscopic Imaging Technique for the Central Screw Placement in Percutaneous Screw Fixation of Scaphoid Fracture
    Lee, Jung Il
    Lee, Yong Seuk
    Cho, Sung Bum
    Rhyu, Im Joo
    Park, Jung Ho
    Kang, Jong Woo
    Jeon, Woo Joo
    Park, Jong Woong
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2010, 68 (03): : 616 - 619
  • [10] Percutaneous Screw Fixation for Scaphoid Fracture: A Comparison Between the Dorsal and the Volar Approaches
    Jeon, In-Ho
    Micic, Ivan D.
    Oh, Chang-Wug
    Park, Byung-Chul
    Kim, Poong-Taek
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2009, 34A (02): : 228 - 236