Effects of digitalis on mortality in a large cohort of implantable cardioverter defibrillator recipients: results of a long-term follow-up study in 1020 patients

被引:18
|
作者
Erath, Julia W. [1 ]
Vamos, Mate [1 ]
Hohnloser, Stefan H. [1 ]
机构
[1] Goethe Univ Frankfurt, Div Clin Electrophys, Dept Cardiol, Theodor Stern Kai 7, D-60590 Frankfurt, Germany
关键词
Digitalis; ICD; Mortality; Atrial fibrillation; Congestive heart failure; ATRIAL-FIBRILLATION; OUTCOMES; THERAPY;
D O I
10.1093/ehjcvp/pvw008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims The effects of digitalis on mortality in patients with structural heart disease are controversially discussed. We aimed to assess the effects of digitalis administration in implantable cardioverter defibrillator (ICD) recipients. Methods and results This retrospective analysis comprises 1020 consecutive patients who received an ICD at our institution and who were followed for up to 10 years (median 37 months). A total of 438 patients were receiving digitalis at the time of ICD implantation and 582 did not. Patients on digitalis were more often in atrial fibrillation and had more often a prolonged QRS duration of = 120 ms, a severely impaired left ventricular ejection fraction, and higher New York Heart Association (NYHA) classification heart failure. Crude Kaplan-Meier analysis demonstrated significantly higher mortality in patients on digitalis (HR = 2.47; 95% CI 1.87-3.25; P = 0.001). After adjustment for patient characteristics found statistically significant in adjusted Cox regression analysis (age, gender, NYHAclassification, and QRS duration of = 120 ms), a HR of 1.65 remained (95% CI 1.14-2.39; P = 0.01). Patients on digitalis died more often from cardiac arrhythmic and cardiac non-arrhythmic causes than patients not on digitalis (P = 0.04). There was no difference in mortality between patients receiving digitoxin and those receiving digoxin (HR = 1.55; 95% CI 0.74-3.25; P = 0.25). Conclusion In this large ICD patient population, digitalis use at baseline was independently associated with increased mortality even after careful adjustment for possible confounders. Digitalis should be used with great caution in this population.
引用
收藏
页码:168 / 174
页数:7
相关论文
共 50 条
  • [1] Long-term follow-up of patients with tetralogy of Fallot and implantable cardioverter defibrillator
    Waldmann, V.
    Bouzeman, A.
    Marquie, C.
    Labombarda, F.
    Koutbi, R.
    Sellal, J. M.
    Fauchier, L.
    Mondoly, P.
    Pasquie, J. L.
    Anselme, F.
    Eschalier, R.
    Iserin, L.
    Thambo, J. B.
    Combes, N.
    Marijon, E.
    [J]. EUROPEAN HEART JOURNAL, 2019, 40 : 1368 - 1368
  • [2] Long-term follow-up of patients with tetralogy of Fallot and implantable cardioverter defibrillator
    Waldmann, V
    Bouzeman, A.
    Duthoit, G.
    Koutbi, R.
    Bessiere, F.
    Labombarda, F.
    Marquie, C.
    Gourraud, J. B.
    Ladouceur, M.
    Mondoly, P.
    Sacher, F.
    Iserin, L.
    Thambo, J. B.
    Combes, N.
    Marijon, E.
    [J]. EUROPEAN HEART JOURNAL, 2020, 41 : 792 - 792
  • [3] Long-term follow-up study of uncertainty and psychosocial adjustment among implantable cardioverter defibrillator recipients
    Mauro, Ann Marie P.
    [J]. INTERNATIONAL JOURNAL OF NURSING STUDIES, 2010, 47 (09) : 1080 - 1088
  • [4] Long-term follow-up of implantable cardioverter defibrillator patients with regard to appropriate therapy, complications, and mortality
    Mattsson, Gustav
    Magnusson, Peter
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2020, 43 (02): : 245 - 253
  • [5] Impact of programming in a large cohort of implantable cardioverter-defibrillator patients with long-term follow-up: findings from the UMBRELLA study
    Briongos Figuero, S.
    Garcia Alberola, A.
    Rubio, J. B.
    Segura, J. M.
    Rodriguez, A.
    Peinado, R.
    Alzueta, J.
    Martinez Ferrer, J. B.
    Vinolas, X.
    Munoz-Aguilera, R.
    Perez, M. L.
    [J]. EUROPEAN HEART JOURNAL, 2021, 42 : 394 - 394
  • [6] Implantable cardioverter defibrillator recipients: comparison of primary and secondary indicated patients during long-term follow-up
    Borleffs, C. J. W.
    Van Welsenes, G. H.
    Van Erven, L.
    Van Bommel, R. J.
    Van der Velde, E. T.
    Rosendaal, F. R.
    Van der Wall, E. E.
    Bax, J. J.
    Schalij, M. J.
    [J]. EUROPEAN HEART JOURNAL, 2009, 30 : 308 - 308
  • [7] Implantable Cardioverter Defibrillator Recipients: Comparison of Primary and Secondary Indicated Patients During Long-Term Follow-up
    Borleffs, C. Jan Willem
    van Welsenes, Guido H.
    van Erven, Lieselot
    van Bommel, Rutger J.
    van der Velde, Enno T.
    Rosendaal, Frits R.
    van der Wall, Ernst E.
    Bax, Jeroen J.
    Schalij, Martin J.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A132 - A132
  • [8] Long-term follow-up of paediatric patients with a subcutaneous implantable cardioverter-defibrillator
    Van der Stuijt, W.
    De Wilde, K. C.
    Baalman, S. W. E.
    Quast, A. B. E.
    Blom, N. A.
    Wilde, A. A. M.
    Knops, R. E.
    [J]. EUROPEAN HEART JOURNAL, 2020, 41 : 3209 - 3209
  • [9] Long-term follow-up of primary and secondary prevention implantable cardioverter defibrillator patients
    van Welsenes, Guido H.
    van Rees, Johannes B.
    Borleffs, C. Jan Willem
    Cannegieter, Suzanne C.
    Bax, Jeroen J.
    van Erven, Lieselot
    Schalij, Martin J.
    [J]. EUROPACE, 2011, 13 (03): : 389 - 394
  • [10] Long-term follow-up of implantable cardioverter, defibrillator therapy for hypertrophic cardiomyopathy
    Jayatilleke, I
    Doolan, A
    Ingles, J
    McGuire, M
    Booth, V
    Richmond, DR
    Semsarian, C
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2004, 93 (09): : 1192 - 1194