Discrimination of Partial Discharges in Gaseous and Liquid Nitrogen by Using Waveform Characteristics

被引:2
|
作者
Yamada, Kazuki [1 ]
Kawashima, Tomohiro [1 ]
Obana, Tetsuhiro [2 ]
Murakami, Yoshinobu [1 ]
Nagao, Masayuki [1 ]
Hozumi, Naohiro [1 ]
机构
[1] Toyohashi Univ Technol, Dept Elect & Elect Informat Engn, Toyohashi, Aichi 4418580, Japan
[2] Natl Inst Fus Sci, Device Engn & Adv Phys Res Div, Toki, Gifu 5095292, Japan
来源
关键词
electrical insulation; partial discharge; waveform characteristics; liquid nitrogen; gaseous nitrogen; BREAKDOWN CHARACTERISTICS;
D O I
10.1585/pfr.15.2401025
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
The cryogenic coolant is important as an electrical insulation in an immersion cooling. One of the dielectric breakdown mechanisms of the cryogenic coolant is via bubbles, caused by partial discharge (PD). The insulation performance has been discussed with PD parameters and breakdown voltage. However, the essential PD mechanism has not been clarified in detail. In this paper, PDs in gaseous and liquid nitrogen were discriminated based on characteristics of the original PD waveform. It was shown that the difference in charge behavior appears significantly in the fall time of the original PD waveform. (C) 2020 The Japan Society of Plasma Science and Nuclear Fusion Research
引用
收藏
页数:4
相关论文
共 50 条
  • [1] The feasibility of using UHF sensors to measure partial discharges in liquid nitrogen
    Truong, L. H.
    Swaffield, D. J.
    Lewin, P. L.
    Judd, M. D.
    [J]. 2011 IEEE INTERNATIONAL CONFERENCE ON DIELECTRIC LIQUIDS (ICDL), 2011,
  • [2] ON THE MECHANISM OF PARTIAL DISCHARGES IN GASEOUS CAVITIES IN CONTACT WITH SOLID OR LIQUID INSULATORS
    BEZBORODKO, P
    LESAINT, O
    TOBAZEON, R
    [J]. PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON CONDUCTION AND BREAKDOWN IN SOLID DIELECTRICS, 1989, : 392 - 396
  • [3] Spectroscopic investigation of corona discharges in liquid and high density gaseous nitrogen
    Nur, M
    HernandezAvila, JL
    Bonifaci, N
    Denat, A
    Belevtsev, AA
    [J]. ICDL 1996 - 12TH INTERNATIONAL CONFERENCE ON CONDUCTION AND BREAKDOWN IN DIELECTRIC LIQUIDS, 1996, : 238 - 242
  • [4] CHARACTERISTICS OF GASEOUS DISCHARGES IN MICRONOZZLES
    GALEEV, IG
    GONCHAROV, VE
    TIMERKAEV, BA
    TOPOROV, VG
    FAKHRUTDINOV, IK
    [J]. HIGH TEMPERATURE, 1992, 30 (03) : 342 - 346
  • [5] Waveform analysis of partial discharge current in liquid nitrogen immersed insulation
    Kanegami, M
    Hozumi, N
    Suzuki, H
    Okamoto, T
    [J]. IEEE 1996 ANNUAL REPORT - CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS I & II, 1996, : 529 - 532
  • [6] SUSCEPTIBILITY OF LIQUID-NITROGEN IMPREGNATED ELECTRICAL INSULATION TO PARTIAL DISCHARGES
    JUCHNIEWICZ, JR
    BULINSKI, AT
    ZAK, W
    [J]. CRYOGENICS, 1975, 15 (07) : 419 - 420
  • [7] Laboratory discrimination of radiated partial discharges
    Ramirez, C.
    Moore, P. J.
    [J]. 2007 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-10, 2007, : 3116 - 3122
  • [8] PARTIAL DISCHARGES IN GASEOUS VOIDS FOR DC VOLTAGE
    KREUGER, FH
    FROMM, U
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1994, 33 (02): : 1079 - 1084
  • [9] Phase Resolved Analysis of Partial Discharges in Liquid Nitrogen Under AC Voltages
    Truong, L. H.
    Lewin, P. L.
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2013, 20 (06) : 2179 - 2187
  • [10] PARTIAL DISCHARGES IN LIQUID-NITROGEN IMPREGNATED, TAPED-CABLE INSULATION
    RIGBY, SJ
    WEEDY, BM
    [J]. PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1976, 123 (02): : 165 - 170