A comprehensive study of the Gafchromic EBT2 radiochromic film. A comparison with EBT

被引:135
|
作者
Andres, C. [1 ]
del Castillo, A. [1 ]
Tortosa, R. [1 ]
Alonso, D. [1 ]
Barquero, R. [2 ]
机构
[1] Hosp Clin Univ, Unidad Radiofis, Valladolid 47003, Spain
[2] Univ Valladolid, Dpto Radiol, Hosp Univ Rio Hortega, Valladolid 47012, Spain
关键词
GafChromic EBT2; GafChromic EBT; Radiochromic film dosimetry; FLAT-BED; DOSE MEASUREMENTS; DOSIMETRY; ABSORPTION; PHOTON; SCANNERS; BEAM; ELECTRON;
D O I
10.1118/1.3512792
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Radiochromic film has become an important tool to assess complex dose distributions. In particular, EBT was accepted by the scientific community as a reference two-dimensional detector. Recently, Gafchromic EBT2 has replaced old film, providing new improvements in both accuracy and handling. Methods: This work presents a dosimetric study of the new Gafchromic EBT2 using an Epson 10000XL flatbed scanner, also comparing the results with EBT film as reference when necessary. The most important film characteristics have been studied, such as ambient light sensitivity, different possibilities of the three RGB color channels, postirradiation development, high dose behavior, exposition at temperatures similar to the human body, and dependence on orientation during the scanning process. Results: The results obtained confirm a considerably lower sensitivity to ambient light of EBT2, as well as a fast stabilization of the film within 2 h. It has also been found that the green channel has a better behavior at high dose levels up to 35 Gy, in addition to good behavior of the red channel at doses below 10 Gy. Other features, such as temperature independence and scanning orientation dependence, have also been shown. Conclusions: Gafchromic EBT2 can be used for clinical practice in the same way as the old EBT film. However, a much easier handling as the result of all new enhancements improves film behavior, expanding in this way the potential applications of radiochromic film dosimetry. (C) 2010 American Association of Physicists in Medicine. [DOI: 10.1118/1.3512792]
引用
收藏
页码:6271 / 6278
页数:8
相关论文
共 50 条
  • [1] Solar ultraviolet radiation response of EBT2 Gafchromic, radiochromic film
    Butson, Ethan T.
    Yu, Peter K. N.
    Butson, Martin J.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (21): : N287 - N294
  • [2] Comparison of Gafchromic EBT, EBT2 and EBT3 radiochromic films when used with flat bed scanners
    Chelminski, K.
    Buczek, B.
    Bulski, W.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S736 - S736
  • [3] A comparison between radiochromic EBT2 film model and its predecessor EBT film model
    Carrasco, M. A.
    Perucha, M.
    Luis, F. J.
    Baeza, M.
    Herrador, M.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2013, 29 (04): : 412 - 422
  • [4] Comparison of the radio chromatic EBT film Dosimetry with EBT2 (Gafchromic) for IMRT Verification
    Schwedas, M.
    Howitz, S.
    Wiezorek, T.
    Wendt, T. G.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 : 105 - 105
  • [5] Neutron response of GafChromic® EBT2 film
    Hsiao, Ming-Chen
    Liu, Yuan-Hao
    Chen, Wei-Lin
    Jiang, Shiang-Huei
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (05): : 1391 - 1413
  • [6] Response of the modified GAFCHROMIC EBT2 radiochromic film to DC glow discharge plasma
    Farag, Omar F.
    Kotb, Omar M.
    El Ghazaly, M.
    EL-Sayed, Naglaa M.
    [J]. SCIENTIFIC REPORTS, 2024, 14 (01)
  • [7] On the registration of low energy alpha particle with modified GafChromic EBT2 radiochromic film
    El-Naggar, Hala I.
    Ghanim, E. H.
    El Ghazaly, M.
    Salama, T. T.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2022, 191
  • [8] Response of the modified GAFCHROMIC EBT2 radiochromic film to DC glow discharge plasma
    Omar F. Farag
    Omar M. Kotb
    M. El Ghazaly
    Naglaa M. EL-Sayed
    [J]. Scientific Reports, 14
  • [9] A Study of Dose Response Characteristic for Gafchromic EBT2 Film
    Chen, W.
    Di, X.
    Wang, S.
    Wang, B.
    Bai, X.
    Yang, J.
    Guo, B.
    Huang, K.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [10] Comparing Homogeneity Between Gafchromic Film EBT2 and EBT3
    Mizuno, H.
    Sumida, I.
    Tanaka, A.
    Ogawa, K.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 239 - 239