Intra-cavity multi-point sensor for C2H2 detection in photoacoustic spectroscopy based on acousto-optic Q-switched fiber laser

被引:0
|
作者
Zhang, Qinduan [1 ,2 ]
Chang, Jun [1 ,2 ]
Cong, Zhenhua [1 ,2 ]
Wang, Zongliang [3 ,4 ]
Wang, Fupeng [1 ,2 ]
Sun, Jiachen [1 ,2 ]
Zhu, Cunguang [5 ]
机构
[1] Shandong Univ, Sch Informat Sci & Engn, Jinan 250100, Peoples R China
[2] Shandong Univ, Shandong Prov Key Lab Laser Technol & Applicat, Jinan 250100, Peoples R China
[3] Liaocheng Univ, Sch Phys Sci & Informat Technol, Liaocheng 252059, Shandong, Peoples R China
[4] Liaocheng Univ, Shandong Key Lab Opt Commun Sci & Technol, Liaocheng 252059, Shandong, Peoples R China
[5] Univ Jinan, Sch Phys & Technol, Jinan 250022, Peoples R China
来源
OPTIK | 2020年 / 206卷
基金
中国国家自然科学基金;
关键词
Multi-point sensor; Fiber laser; Photoacoustic spectroscopy; HIGH-SENSITIVITY; ACETYLENE;
D O I
10.1016/j.ijleo.2020.164277
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In this paper, we reported a new multi-point sensor for C2H2 detection based on photoacoustic spectroscopy and acousto-optic Q-switched fiber laser. Three transmission-type PAS cells were placed inside the fiber laser cavity and used for C2H2 detection simultaneously to demonstrate the potential of spatially resolved measurements. A maximum pulse peak power of similar to 544 mW was generated by the acousto-optic Q-switched fiber laser. The signal-to-noise ratios (SNR) calculated from the experimental results was 57.7 dB, 45.1 dB and 57.2 dB. This resulted in a minimum detection limit (MDL) for C2H2 of 1.73 ppmv, 7.82 ppmv and 1.93 ppmv for PAS cell 1, PAS cell 2 and PAS cell 3, respectively.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Intra-cavity multi-point sensor for C2H2 detection in photoacoustic spectroscopy based on acousto-optic Q-switched fiber laser
    Zhang, Qinduan
    Chang, Jun
    Cong, Zhenhua
    Wang, Zongliang
    Wang, Fupeng
    Sun, Jiachen
    Zhu, Cunguang
    [J]. Optik, 2020, 206
  • [2] Acousto-Optic Q-Switched Fiber Laser-Based Intra-Cavity Photoacoustic Spectroscopy for Trace Gas Detection
    Zhang, Qinduan
    Chang, Jun
    Wang, Qiang
    Wang, Zongliang
    Wang, Fupeng
    Qin, Zengguang
    [J]. SENSORS, 2018, 18 (01):
  • [3] The fiber ring laser intra-cavity gas sensor for C2H2 and CO2 detection based on photoacoustic spectroscopy
    Zhang, Hengbiao
    Bi, Shaoqiang
    Zhang, Qinduan
    Tian, Cunwei
    Wang, Zongliang
    [J]. INFRARED PHYSICS & TECHNOLOGY, 2023, 131
  • [4] Multi-point, fiber-optic gas detection with intra-cavity spectroscopy
    Zhang, Y
    Zhang, M
    Jin, W
    [J]. OPTICS COMMUNICATIONS, 2003, 220 (4-6) : 361 - 364
  • [5] Q-switched fiber laser based on an acousto-optic modulator with injection seeding technique
    Li, Wencai
    Liu, Haowei
    Zhang, Ji
    Long, Hu
    Feng, Sujuan
    Mao, Qinghe
    [J]. APPLIED OPTICS, 2016, 55 (17) : 4584 - 4588
  • [6] Experimental researches on acousto-optic Q-switched CO2 laser
    He, Yang
    Lu, Jun
    Chen, Fei
    Li, Dianjun
    Zheng, Changbin
    Xie, Jijiang
    Guo, Jin
    [J]. Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2015, 44 (08): : 2280 - 2285
  • [7] The intra-cavity QEPAS sensor using fiber-ring laser for C2H2 and CO2 detection
    Zhang, Hengbiao
    Yu, Yuanfang
    Bi, Shaoqiang
    Zhang, Qinduan
    Tian, Cunwei
    Wang, Zongliang
    [J]. MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2023, 65 (11) : 3021 - 3026
  • [8] Acousto-optic Q-switched Er:CaF2-SrF2 laser at 2.73 μm
    Liu, Jingjing
    Zong, Mengyu
    Wang, Dongzhou
    Zhang, Zhen
    Liu, Jie
    Su, Liangbi
    [J]. INFRARED PHYSICS & TECHNOLOGY, 2021, 116
  • [9] Acousto-Optic Q-Switched Ho:YLF Ring Laser Based on Anti-Misalignment Resonant Cavity
    Wang, Yunpeng
    Zhang, Dongming
    Yan, Dong
    Dai, Tongyu
    Ju, Youlun
    [J]. PHOTONICS, 2023, 10 (10)
  • [10] Pptv-Level Intra-Cavity QEPAS Sensor for Acetylene Detection Using a High Power Q-Switched Fiber Laser
    Zhang, Qinduan
    Chang, Jun
    Cong, Zhenhua
    Bong, Yiwen
    Wang, Zongliang
    Wang, Fupeng
    Sun, Jiachen
    [J]. IEEE SENSORS JOURNAL, 2019, 19 (15) : 6181 - 6186