Open Reduction and Internal Fixation of Extraarticular Scapular Neck and Body Fractures With Good Short Term Functional Outcome

被引:3
|
作者
Asihin, Muhammad Azrin Mohd [1 ]
Bajuri, Mohd Yazid [2 ]
Ganaisan, Premganesh K. [1 ]
Ahmad, Abdul Rauf [1 ]
机构
[1] Hosp Tuanku Jaafar, Dept Orthopaed, Seremban, Malaysia
[2] Univ Kebangsaan Malaysia, Med Ctr, Hosp Canselor Tuanku Mukhriz, Dept Orthopaed & Traumatol, Kuala Lumpur, Malaysia
来源
FRONTIERS IN SURGERY | 2019年 / 6卷
关键词
extraarticular; scapula fracture; decision making; functional outcome; open reduction; OPERATIVE MANAGEMENT; GLENOID NECK; SF-36;
D O I
10.3389/fsurg.2019.00071
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: The study aims to evaluate the short-term functional outcome of open reduction and internal fixation of extraarticular scapular neck and body fractures treated at our center over a period of 2-year duration at a tertiary referral center. Patients and Methods: Between October 2015 and October 2017, we operated on 20 extraarticular scapular neck and body fracture. Ten were available for a one-off assessment. The mean time to surgery was 10 days (range, 3-19 days) and one-off assessment was done within 6-24 months (mean, 13 months). Indications includes (1) medial/lateral displacement (M/L) >= 20 mm, (2) M/L >= 15 mm if angular deformity >= 30 degrees, (3) Angular deformity >= 45 degrees, (4) Double lesion of superior shoulder suspensory complex (SSSC), with displacement >= 10 mm in both lesion, (5) Glenopolar angle (GPA) <= 22 degrees, and (6) open scapular fracture. The functional outcome was measured using range motion and strength. Patient-reported outcome was assessed using Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire and Short-Form-36 (SF-36) version 1. Results: All patients achieved radiological union at time of assessment. None of the patients had post-operative complications. The mean DASH score was 19.3 (range, 1.7-39.3). All subcategories of SF-36 questionnaire scores between 70 and 89.6, with exception to REE (role limitations due to emotional problems) and REP (role limitations due to physical health). The average range of motion for the injured shoulders; forward flexion 157 degrees, abduction 114 degrees, and external rotation 42 degrees. The strength of operated and non-operated shoulders, respectively, 6.5 and 8.1 kgF of forward flexion, 5.5 and 7.2 kgF of abduction, and 4.1 and 6.3 kgF of external rotation. Conclusion: Open reduction and internal fixation of surgically indicated scapular neck and body fracture is feasible with predictably good functional outcome. The reduced external rotation ROM and strength may be due to the use of Classic Judet approach, however we do not enough data to support this.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] OPEN REDUCTION AND INTERNAL-FIXATION OF IPSILATERAL FRACTURES OF THE SCAPULAR NECK AND CLAVICLE
    LEUNG, KS
    LAM, TP
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (07): : 1015 - 1018
  • [2] Posterior Approach for Open Reduction and Internal Fixation for Scapular Fractures
    Nelson, Chase T.
    Thorne, Tyler J.
    Higgins, Thomas F.
    Rothberg, David L.
    Haller, Justin M.
    Marchand, Lucas S.
    JBJS ESSENTIAL SURGICAL TECHNIQUES, 2023, 13 (03):
  • [3] A short term functional outcome study comparing closed reduction percutaneous wire fixation with open reduction internal fixation for fractures of the distal radius: a pilot study
    Cooper, Lisa
    Mauffrey, Cyril
    Hull, Peter
    Brewster, Mark
    Lewis, Charlie
    Makrides, Panos
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2008, 18 (08): : 551 - 554
  • [4] A short term functional outcome study comparing closed reduction percutaneous wire fixation with open reduction internal fixation for fractures of the distal radius: a pilot study
    Lisa Cooper
    Cyril Mauffrey
    Peter Hull
    Mark Brewster
    Charlie Lewis
    Panos Makrides
    European Journal of Orthopaedic Surgery & Traumatology, 2008, 18 : 551 - 554
  • [5] A Prospective Study on Functional Outcome of Open Reduction and Internal Fixation of Acetabular Fractures
    Pillella, Venkata Kiran
    John, J. Lionel
    JOURNAL OF PHARMACEUTICAL RESEARCH INTERNATIONAL, 2020, 32 (13) : 174 - 183
  • [6] DISPLACED SCAPULAR FRACTURES - INDICATION AND LONG-TERM RESULTS OF OPEN REDUCTION AND INTERNAL-FIXATION
    BAUER, G
    FLEISCHMANN, W
    DUSSLER, E
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1995, 114 (04) : 215 - 219
  • [7] OPEN REDUCTION AND INTERNAL FIXATION OF UNUNITED FRACTURES OF THE NECK OF THE FEMUR
    WALKER, HR
    TOFFELMIER, DD
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1953, 35-A (03): : 788 - 789
  • [8] Functional and Radiologic Outcome of Open Reduction and Internal Fixation of Condylar Head and Neck Fractures Using Miniplate or Microplate System
    Xie, Si-Tian
    Singhal, Dhruv
    Chen, Chien-Tzung
    Chen, Yu-Ray
    ANNALS OF PLASTIC SURGERY, 2013, 71 : S61 - S66
  • [9] Functional outcome of patients following open reduction internal fixation for bilateral calcaneus fractures
    Zmurko, MG
    Karges, DE
    FOOT & ANKLE INTERNATIONAL, 2002, 23 (10) : 917 - 921
  • [10] Outcome Following Open Reduction and Internal Fixation of Open Pilon Fractures
    Boraiah, Sreevathsa
    Kemp, Travis J.
    Erwteman, Andrew
    Lucas, Paul A.
    Asprinio, David E.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (02): : 346 - 352