A New Approach Combining Analytical Methods for Workplace Exposure Assessment of Inhalable Multi-Walled Carbon Nanotubes

被引:7
|
作者
Tromp, Peter C. [1 ]
Kuijpers, Eelco [1 ,2 ]
Bekker, Cindy [1 ,2 ]
Godderis, Lode [3 ,4 ]
Lan, Qing [5 ]
Jedynska, Aleksandra D. [1 ]
Vermeulen, Roel [2 ]
Pronk, Anjoeka [1 ]
机构
[1] TNO, Netherlands Org Appl Res, Utrecht, Netherlands
[2] IRAS, Mol Epidemiol & Risk Assessment Utrecht, Utrecht, Netherlands
[3] Katholieke Univ Leuven, Ctr Environm & Hlth, Leuven, Belgium
[4] IDEWE, External Serv Prevent & Protect Work, Heverlee, Belgium
[5] NCI, Occupat & Environm Epidemiol Branch, Div Canc Epidemiol & Genet, Bethesda, MD 20892 USA
关键词
carbon analysis; ICP-MS; multi-walled carbon nanotubes; scanning electron microscopy; PARTICULATE MATTER; NANOFIBER PRIMARY; ELEMENTAL CARBON; PART I; PARTICLES; MOBILITY; DENSITY; MASS; AEROSOLS; SAMPLER;
D O I
10.1093/annweh/wxx053
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
To date there is no consensus about the most appropriate analytical method for measuring carbon nanotubes (CNTs), hampering the assessment and limiting the comparison of data. The goal of this study is to develop an approach for the assessment of the level and nature of inhalable multi-wall CNTs (MWCNTs) in an actual workplace setting by optimizing and evaluating existing analytical methods. In a company commercially producing MWCNTs, personal breathing zone samples were collected for the inhalable size fraction with IOM samplers; which were analyzed with carbon analysis, inductively coupled plasma mass spectrometry (ICP-MS) and scanning electron microscopy/ energy dispersive X-ray spectroscopy (SEM/EDX). Analytical methods were optimized for carbon analysis and SEM/EDX. More specifically, methods were applied and evaluated for background correction using carbon analyses and SEM/EDX, CNT structure count with SEM/EDX and subsequent mass conversion based on both carbon analyses and SEM/EDX. A moderate-to-high concordance correlation coefficient (R-C) between carbon analyses and SEM/EDX was observed [R-C = 0.81, 95% confidence interval (CI): 0.59-0.92] with an absolute mean difference of 59 mu g m(-3). A low R-C between carbon analyses and ICP-MS (R-C = 0.41, 95% CI: 0.07-0.67) with an absolute mean difference of 570 mu g m-3 was observed. The large absolute difference between EC and metals is due to the presence of non-embedded inhalable catalyst particles, as a result of which MWCNT concentrations were over-estimated. Combining carbon analysis and SEM/EDX is the most suitable for quantitative exposure assessment of MWCNTs in an actual workplace situation.
引用
收藏
页码:759 / 772
页数:14
相关论文
共 50 条
  • [1] Multi-walled carbon nanotubes (Baytubes®): Approach for derivation of occupational exposure limit
    Pauluhn, Juergen
    REGULATORY TOXICOLOGY AND PHARMACOLOGY, 2010, 57 (01) : 78 - 89
  • [2] Multi-Walled Carbon Nanotubes
    Morais, Simone
    APPLIED SCIENCES-BASEL, 2019, 9 (13):
  • [3] Biomembrane damage caused by exposure to multi-walled carbon nanotubes
    Shimizu, Kosuke
    Uchiyama, Arina
    Yamashita, Mina
    Hirose, Akihiko
    Nishimura, Tetsuji
    Oku, Naoto
    JOURNAL OF TOXICOLOGICAL SCIENCES, 2013, 38 (01): : 7 - 12
  • [4] Effects of Subchronic Exposure to Multi-Walled Carbon Nanotubes on Mice
    Liang, Geyu
    Yin, Lihong
    Zhang, Juan
    Liu, Ran
    Zhang, Tao
    Ye, Bing
    Pu, Yuepu
    JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH-PART A-CURRENT ISSUES, 2010, 73 (07): : 463 - 470
  • [5] A new approach to functionalize multi-walled carbon nanotubes by the use of functional polymers
    Hong, Chun-Yan
    You, Ye-Zi
    Pan, Cai-Yuan
    POLYMER, 2006, 47 (12) : 4300 - 4309
  • [6] Comparison of different methods for characterizing multi-walled carbon nanotubes
    Gommes, C
    Blacher, S
    Dupont-Pavlovsky, N
    Bossuot, C
    Lamy, M
    Brasseur, A
    Marguillier, D
    Fonseca, A
    McRae, E
    Nagy, JB
    Pirard, JP
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2004, 241 (1-3) : 155 - 164
  • [7] Preparation and Characterization of Oxidized Multi-Walled Carbon Nanotubes and Glycine Functionalized Multi-Walled Carbon Nanotubes
    Deborah, M.
    Jawahar, A.
    Mathavan, T.
    Dhas, M. Kumara
    Benial, A. Milton Franklin
    FULLERENES NANOTUBES AND CARBON NANOSTRUCTURES, 2015, 23 (07) : 583 - 590
  • [8] Purification of Multi-Walled Carbon Nanotubes
    Pillai, Sreejarani K.
    Ray, Suprakas Sinha
    Moodley, Mathew
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2008, 8 (12) : 6187 - 6207
  • [9] Nitrogenation of multi-walled carbon nanotubes
    Bitter, Julie L.
    Fairbrother, Howard
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2010, 240
  • [10] Functionalization of multi-walled carbon nanotubes
    Gergely, A.
    Telegdi, J.
    Kalman, E.
    MATERIALS SCIENCE, TESTING AND INFORMATICS III, 2007, 537-538 : 623 - +