Bridging the Gap between Point-of-Care Testing and Laboratory Testing in Hemostasis

被引:18
|
作者
Kitchen, Dianne P. [1 ]
Jennings, Ian [1 ]
Kitchen, Steve [1 ]
Woods, Timothy A. L. [1 ]
Walker, Isobel D. [1 ]
机构
[1] UK Natl External Qual Assessment Scheme Blood Coa, Sheffield S10 2QD, S Yorkshire, England
来源
SEMINARS IN THROMBOSIS AND HEMOSTASIS | 2015年 / 41卷 / 03期
关键词
point of care; INR monitoring; primary care; secondary care; ORAL ANTICOAGULANT-THERAPY; VITAMIN-K ANTAGONISTS; BRITISH COMMITTEE; HEMATOLOGY; GUIDELINES; MANAGEMENT; STANDARDS; PROFESSIONALS; GUIDANCE; PROGRAM;
D O I
10.1055/s-0035-1544197
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Point-of-care (POC) testing within hemostasis is an expanding field, with the most widely used test being POC international normalized ratio (INR). Many of these devices are being used in a nonlaboratory setting by staff with no laboratory training. In the United Kingdom, external quality assessment (EQA) is provided by the organization UK National External Quality Assessment Scheme for Blood Coagulation (UK NEQAS BC). Participants within the UK NEQAS BC POC INR program are largely based in primary care (77%), with the majority of EQA samples and patients tests being performed by nurses (70%). Many of these centers do not have support from the laboratory staff and may, therefore, not understand the requirement for a robust quality control (QC) system comprising both internal quality control (IQC) and EQA. From data acquired through a questionnaire of these UK NEQAS BC users, we observed that 2% of the centers never perform IQC tests, only 29% perform IQC tests when starting a new batch of test strips, and just 15% carry out IQC with each clinic as recommended by the UK guidelines. The imprecision of EQA tests was greater for POC users than in the UK NEQAS BC hospital laboratory program, with average coefficients of variation for a 2-year period of 11.0 and 7.3%, respectively. This may reflect the handling of EQA samples rather than the imprecision of the method, due to the lack of laboratory training amongst POC staff. POC INR in the UK could greatly benefit from more interaction and support from laboratories to these POC testers.
引用
收藏
页码:272 / 278
页数:7
相关论文
共 50 条
  • [1] Utilization of Point-of-Care Testing in hemostasis
    Nuttall, G
    [J]. CLINICAL CHEMISTRY, 2001, 47 (06) : S20 - S20
  • [2] Point-of-care Laboratory Testing
    Gauglitz, Guenter
    Luppa, Peter B.
    [J]. CHEMIE IN UNSERER ZEIT, 2009, 43 (05) : 308 - 318
  • [3] Point-of-Care Testing of Hemostasis in Cardiac Surgery
    Domenico Prisco
    Rita Paniccia
    [J]. Thrombosis Journal, 1 (1)
  • [4] Bridging the gap between development of point-of-care nucleic acid testing and patient care for sexually transmitted infections
    Hsieh, Kuangwen
    Melendez, Johan H.
    Gaydos, Charlotte A.
    Wang, Tza-Huei
    [J]. LAB ON A CHIP, 2022, 22 (03) : 476 - 511
  • [5] Point-of-care Testing versus Central Laboratory Testing of Electrolytes in Neonates
    Choi, Ha-young
    Corder, Wil
    Abubakar, Kabir
    [J]. PEDIATRICS, 2018, 141
  • [6] The Equine Neonatal Intensive Care Laboratory: Point-of-Care Testing
    Wilkins, Pamela A.
    [J]. CLINICS IN LABORATORY MEDICINE, 2011, 31 (01) : 125 - +
  • [7] Laboratory testing during critical care transport: point-of-care testing in air ambulances
    Di Serio, Francesca
    Petronelli, Maria Antonia
    Sammartino, Eugenio
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2010, 48 (07) : 955 - 961
  • [8] Point-of-Care Testing: The Good, the Bad, and the Laboratory Oversight
    Shaw, Julie L. V.
    [J]. JOURNAL OF APPLIED LABORATORY MEDICINE, 2021, 6 (04): : 1090 - 1093
  • [9] THE SATELLITE LABORATORY AND POINT-OF-CARE TESTING - INTEGRATION OF INFORMATION
    JACOBS, E
    LAUDIN, AG
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1995, 104 (04) : S33 - S39
  • [10] POINT-OF-CARE TESTING
    Newnam, Katherine M.
    [J]. ADVANCES IN NEONATAL CARE, 2018, 18 (02) : 84 - +