Dusting Hole Film Cooling Heat Transfer on a Transonic Turbine Blade Tip

被引:0
|
作者
Manneschmidt, Ward [1 ]
Collopy, Hallie [1 ]
Ligrani, Phillip [1 ]
Goethals, Kyle [1 ]
Cox, Matthew [1 ]
Xu, Hongzhou [2 ]
Fox, Michael [2 ]
机构
[1] Univ Alabama, Huntsville, AL 35899 USA
[2] Solar Turbines Inc, San Diego, CA 92186 USA
关键词
HIGH-PRESSURE TURBINE; SQUEALER TIP; LEAKAGE FLOW; OPTIMIZATION; PERFORMANCE;
D O I
10.1155/2022/2006572
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Investigated is a transonic turbine blade tip with a squealer rim and a squealer recess, with a single dusting film cooling hole contained within the leading edge region of the squealer recess. Data are provided for transonic flow conditions for a range of film cooling blowing ratios for two tip gap values, using a linear cascade, with no relative motion between the blade and the casing. Surface heat transfer characteristics are measured using the transient impulse-response measurement approach, employed with infrared thermography. Line-averaged adiabatic film cooling effectiveness values, for the 1.4 mm tip gap, are generally very small along the pressure side rim, with only small, locally increased values along the suction side rim. For the 0.8 mm tip gap, line-averaged adiabatic film cooling effectiveness values are generally somewhat higher along the pressure side rim and along the suction side rim. In general, effectiveness values for both tip gap values, for these locations, and for the recess region, increase as the blowing ratio increases. As the tip gap decreases from 1.4 mm to 0.8 mm, line-averaged adiabatic film cooling effectiveness generally increases on the rims and downstream regions of the recess, with increased magnitudes which are spread over larger spatial surface areas. For tip gaps of 0.8 mm and 1.4 mm, for regions where the line-averaged heat transfer coefficient ratio deviates significantly from 1.00, values generally decrease as the blowing ratio increases. Across every region of the blade, line-averaged heat transfer coefficient ratios either decrease or remain approximately invariant, as the tip gap value decreases from 1.4 mm to 0.8 mm.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Effects of dusting film cooling placement and configuration on surface heat transfer characteristics of a transonic turbine squealer blade tip
    Collopy, Hallie
    Ligrani, Phillip
    Manneschmidt, Ward
    Xu, Hongzhou
    Fox, Michael
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2023, 212
  • [2] Transonic Turbine Blade Tip Heat Transfer with Pressure Side Film Cooling
    Collopy, Hallie
    Ligrani, Phillip M.
    Xu, Hongzhou
    Fox, Michael
    [J]. JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2022, 36 (03) : 720 - 733
  • [3] Effects of tip gap on transonic turbine blade heat transfer characteristics with pressure side film cooling
    Collopy, Hallie
    Ligrani, Phillip M.
    Xu, Hongzhou
    Fox, Michael
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2022, 187
  • [4] Effects of pressure side film cooling hole placement and condition on surface heat transfer coefficients along a transonic turbine blade tip
    Collopy, Hallie
    Ligrani, Phillip M.
    Xu, Hongzhou
    Fox, Michael
    [J]. INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2023, 192
  • [5] Blade-tip heat transfer in a transonic turbine
    Thorpe, SJ
    Yoshino, S
    Thomas, GA
    Ainsworth, RW
    Harvey, NW
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2005, 219 (A6) : 421 - 430
  • [6] Heat transfer and film cooling effectiveness on the squealer tip of a turbine blade
    Park, Jun Su
    Lee, Dong Hyun
    Rhee, Dong-Ho
    Kang, Shin Hyung
    Cho, Hyung Flee
    [J]. ENERGY, 2014, 72 : 331 - 343
  • [7] Investigations of film cooling and heat transfer on a turbine blade squealer tip
    He, Kun
    [J]. APPLIED THERMAL ENGINEERING, 2017, 110 : 630 - 647
  • [8] Film cooling characteristics analysis of turbine blade tip in transonic flow
    Zhang, Bolun
    Xia, Jun
    Hu, Qigao
    Zhu, Huiren
    [J]. Guofang Keji Daxue Xuebao/Journal of National University of Defense Technology, 2024, 46 (02): : 153 - 161
  • [9] Effect of cooling-hole distributions on heat transfer and cooling effectiveness on turbine blade tip
    Huang Y.
    Yan X.
    He K.
    Li J.
    [J]. Yan, Xin, 2016, Xi'an Jiaotong University (50): : 101 - 107
  • [10] Effects of pressure side film cooling hole placement and condition on adiabatic film cooling effectiveness characteristics of a transonic turbine blade tip
    Collopy, Hallie
    Ligrani, Phillip M.
    Xu, Hongzhou
    Fox, Michael
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2022, 199