Sequential Injection Analysis Hyphenated with Other Flow Techniques: A Review

被引:10
|
作者
Pinto, Paula C. A. G. [1 ]
Lucia, M. [1 ]
Saraiva, M. F. S. [1 ]
Lima, Jose L. F. C. [1 ]
机构
[1] Univ Porto, Fac Farm, Serv Quim Fis, REQUIMTE, P-4099030 Oporto, Portugal
关键词
Flow techniques; Hyphenization; Review; SIA; ATOMIC-ABSORPTION-SPECTROMETRY; LAB-ON-VALVE; PLASMA-MASS SPECTROMETRY; WETTING-FILM EXTRACTION; SOLID-PHASE EXTRACTION; AUTOMATED SAMPLE PREPARATION; 2 POTENTIOMETRIC DETECTORS; BEADS PACKED-COLUMN; GRANS PLOT METHOD; ANALYSIS SYSTEM;
D O I
10.1080/00032719.2010.500780
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the last two decades, sequential injection analysis (SIA) became an important automation tool in several analytical fields as it provided advantages in terms of versatility, robustness, and consumption of samples and reagents. The noteworthy versatility of an SIA selection valve allowed its association with several units, including devices typically associated with other flow techniques, resulting in generally better analytical performance. This review discusses the hyphenization of SIA with other flow approaches outlining its advantages and motivations, which are related mainly with sample manipulation and solutions management. The future trends and perspectives in this field are also addressed.
引用
收藏
页码:374 / 397
页数:24
相关论文
共 50 条
  • [1] Tandem (hyphenated or coupled) flow injection systems: a new dimension in flow injection analysis
    Van, Staden, J. F.
    South African Journal of Chemistry, 49 (3-4):
  • [2] Tandem (hyphenated or coupled) flow injection systems: A new dimension in flow injection analysis
    vanStaden, JF
    SOUTH AFRICAN JOURNAL OF CHEMISTRY-SUID-AFRIKAANSE TYDSKRIF VIR CHEMIE, 1996, 49 (3-4): : 53 - 58
  • [3] Multisyringe flow injection analysis in spectroanalytical techniques - A review
    Cerda, Victor
    Ferrer, Laura
    Portugal, Lindomar A.
    de Souza, Cheilane T.
    Ferreira, Sergio L. C.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2018, 98 : 1 - 18
  • [4] Automated Determination of Captopril by Flow and Sequential Injection Analysis: A Review
    Tzanavaras, Paraskevas D.
    ANALYTICAL LETTERS, 2011, 44 (1-3) : 560 - 576
  • [5] REVIEW ON HYPHENATED ANALYTICAL TECHNIQUES IMPLEMENTED FOR ANALYSIS OF ROSUVASTATIN
    Shirkhedkar, Atul A.
    Mahajan, Pankaj D.
    Patil, Amod S.
    INDO AMERICAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2019, 6 (05): : 9183 - 9195
  • [6] ION CHROMATOGRAPHY, FLOW-INJECTION ANALYSIS AND OTHER TECHNIQUES FOR THE FUTURE
    TSANG, WS
    BENGTSSON, M
    TJEBBES, J
    CLARKE, MA
    ZUCKERINDUSTRIE, 1991, 116 (01): : 42 - 47
  • [7] CONTINUOUS SEPARATION TECHNIQUES IN FLOW-INJECTION ANALYSIS - A REVIEW
    VALCARCEL, M
    DECASTRO, MDL
    JOURNAL OF CHROMATOGRAPHY, 1987, 393 (01): : 3 - 23
  • [8] CONTINUOUS PRECIPITATION TECHNIQUES IN FLOW-INJECTION ANALYSIS - A REVIEW
    KUBAN, V
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 346 (10-11): : 873 - 881
  • [9] Arsenic speciation analysis in water samples: A review of the hyphenated techniques
    Terlecka, E
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2005, 107 (1-3) : 259 - 284
  • [10] Recent applications of flow-injection and sequential-injection analysis techniques to chemiluminescence determination of pharmaceuticals
    Mervartova, Katerina
    Polasek, Miroslav
    Calatayud, Jose Martinez
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 45 (03) : 367 - 381