Performance results of a new DOI detector block for a high resolution PET-LSO research tomograph HRRT

被引:0
|
作者
Schmand, M [1 ]
Eriksson, L [1 ]
Casey, ME [1 ]
Andreaco, MS [1 ]
Melcher, C [1 ]
Wienhard, K [1 ]
Flugge, G [1 ]
Nutt, R [1 ]
机构
[1] CTI PET Syst Inc, Knoxville, TN USA
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
To improve the spatial resolution and uniformity in modern high resolution brain PET systems over the entire field of view (FOV), it is necessary to archive the depth of interaction (DOI) information and correct for spatial resolution degradation. In this work we present the performance results of a high resolution LSO/GSO phoswich block detector with DOI capability. This detector design will be used in the new CTI High Resolution Research Tomograph, ECAT HRRT. The two crystal layer (19x19x7.5 mm(3)) and a light guide are stacked on each other and mounted on a (2x2) PMT set, so that the corners of the phoswich are positioned over the PMT centers. The crystal phoswich is cut into a 8x8 matrix of discrete crystals. The separation of the LSO and the GSO layer by pulse shape discrimination allows discrete DOI information to be obtained. The high light output and the light guide design results in an accurate identification of the 128 single crystals per block. Flood source measurements document a very good homogeneity of events, energy centroid stability and energy resolution (14-20% FWHM) per single crystal. An intrinsic resolution of similar to 1.3 nm and the DOI feasibility is extracted by coincidence measurements with a single GSO crystal.
引用
收藏
页码:934 / 938
页数:5
相关论文
共 50 条
  • [1] Performance results of a new DOI detector block for a High Resolution PET-LSO Research Tomograph HRRT
    Schmand, M
    Eriksson, L
    Casey, ME
    Andreaco, MS
    Melcher, C
    Wienhard, K
    Flügge, G
    Nutt, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (06) : 3000 - 3006
  • [2] Performance evaluation of a new LSO High Resolution Research Tomograph -: HRRT
    Schmand, M
    Wienhard, K
    Casey, ME
    Eriksson, L
    Jones, WF
    Reed, JH
    Treffert, J
    Lenox, M
    Luk, P
    Bao, J
    Young, JW
    Baker, K
    Miller, SD
    Knoess, C
    Vollmar, S
    Richerzhagen, N
    Flügge, G
    Heiss, WD
    Nutt, R
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1067 - 1071
  • [3] HRRT a new high resolution LSO-FET research tomograph.
    Schmand, M
    Casey, ME
    Wienhard, K
    Eriksson, L
    Jones, WF
    Lenox, M
    Young, JW
    Baker, K
    Miller, SD
    Reed, JH
    Heiss, WD
    Nutt, R
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 76P - 76P
  • [4] Characteristics of a single LSO crystal layer high resolution research tomograph (HRRT) PET scanner.
    Boellaard, R
    Buijs, F
    Lenox, N
    Casey, ME
    Gremillion, T
    Jagt, P
    Lammertsma, AA
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 226P - 227P
  • [5] The ECAT HRRT: Performance and first clinical application of the new high resolution research tomograph
    Wienhard, K
    Schmand, M
    Casey, ME
    Baker, K
    Bao, J
    Eriksson, L
    Jones, WF
    Knoess, C
    Lenox, M
    Lercher, M
    Luk, P
    Michel, C
    Reed, JH
    Richerzhagen, N
    Treffert, J
    Vollmar, S
    Young, JW
    Heiss, WD
    Nutt, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (01) : 104 - 110
  • [6] Evaluation of the Depth of Interaction (DOI) for the High Resolution Research Tomograph (HRRT) - a comparison between scanners with and without DOI
    Knoess, C
    Boellaard, R
    Lenox, M
    Vollmar, S
    Casey, M
    Fluegge, G
    Lammertsma, A
    Wienhard, K
    Heiss, WD
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1447 - 1451
  • [7] Evaluation of a new high resolution research tomograph: The ECAT HRRT.
    Wienhard, K
    Lenox, M
    Knoess, C
    Bao, J
    Burbar, Z
    Byars, L
    Casey, ME
    Eriksson, L
    Gremillion, T
    Jones, WF
    Luk, P
    Michel, C
    Reed, JH
    Richerzhagen, N
    Roddy, R
    Vollmar, S
    Watson, C
    Young, JW
    Heiss, WD
    Nutt, R
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 227P - 227P
  • [8] The ECAT HRRT: NEMA NEC evaluation of the HRRT system, the new high resolution research tomograph.
    Wienhard, K
    Eriksson, L
    Eriksson, M
    Casey, ME
    Knoess, C
    Bruckbauer, T
    Hamill, J
    Schmand, M
    Gremillion, T
    Lenox, A
    Conti, M
    Bendriem, B
    Heiss, WD
    Nutt, R
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1227 - 1230
  • [9] The ECAT HRRT: NEMA NEC evaluation of the HRRT system, the new high-resolution research tomograph
    Eriksson, L
    Wienhard, K
    Eriksson, M
    Casey, ME
    Knoess, C
    Bruckbauer, T
    Hamill, J
    Schmand, M
    Gremillion, T
    Lenox, M
    Conti, M
    Bendriem, B
    Heiss, WD
    Nutt, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) : 2085 - 2088
  • [10] Development of a daily quality check procedure for the High Resolution Research Tomograph (HRRT) using natural LSO background radioactivity
    Knoess, C
    Gremillion, T
    Schmand, M
    Casey, ME
    Eriksson, L
    Lenox, M
    Treffert, JT
    Vollmar, S
    Fluegge, G
    Wienhard, K
    Heiss, WD
    Nutt, R
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1115 - 1119