Assessment of Usability of Armoured Single-Core Low Voltage Power Cables

被引:0
|
作者
Pipa, Marek [1 ]
Kment, Attila [1 ]
Lelak, Jaroslav [1 ]
Janicek, Frantisek [1 ]
机构
[1] Fac Elect Engn & Informat Technol STU Bratislava, Inst Power & Appl Elect Engn, Bratislava, Slovakia
关键词
armouring of cables; LV cables; LV power distribution; voltage drop;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Increase of mechanical immunity of LV cables wrapped around the steel tape and with the final plastic coating can achieve a significant reduction in the likelihood of failure caused by improper / negligent installation and the occurrence of unforeseen mechanical factors. For cables with internal sealed a three-phase system, it may be a good choice. Substantial problems may arise when single-core cable system is armored. Customer may by entice by easier installation - especially in larger dimensions, but he may be a backfire in operation. What are the possible impacts and consequences, here are supported by results of measurements in this paper
引用
收藏
页码:402 / 405
页数:4
相关论文
共 50 条
  • [1] Usability of Armoured Single-core Low Voltage Power Cables
    Pipa, Marek
    Kment, Attila
    Lelak, Jaroslav
    Janicek, Frantisek
    PROCEEDINGS OF THE 8TH INTERNATIONAL SCIENTIFIC SYMPOSIUM ON ELECTRICAL POWER ENGINEERING (ELEKTROENERGETIKA 2015), 2015, : 236 - 239
  • [2] A calculation model for determination of impedance of power high voltage single-core cables with polymer insulation
    Bezprozvannych, G., V
    Kostiukov, I. A.
    ELECTRICAL ENGINEERING & ELECTROMECHANICS, 2021, (03) : 47 - 51
  • [3] Analysis and optimation for operation of the single-core power cables in parallel
    Fan, You-Bing
    Zhao, Jian-Kang
    Qian, Kang
    Meng, Shao-Xin
    Dou, Fei
    Peng, Chao
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (10): : 2607 - 2612
  • [4] Assessment of dielectric strength and partial discharges patterns in nanocomposites insulation of single-core power cables
    Thabet, Ahmed
    Fouad, M.
    JOURNAL OF ADVANCED DIELECTRICS, 2021, 11 (04)
  • [5] Influence of semiconducting layers on the attenuation behaviour of single-core power cables
    Steinbrich, K
    IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2005, 152 (02) : 271 - 276
  • [6] PROPOSALS FOR INSTALLATION PRACTICE OF SINGLE-CORE CABLES
    FOULSHAM, N
    METCALFE, JC
    PHILBRIC.SE
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1974, 121 (10): : 1168 - 1174
  • [7] Harmonic impedance of single-core armored cables
    Yuan, ZH
    Du, Y
    2003 IEEE PES TRANSMISSION AND DISTRIBUTION CONFERENCE & EXPOSITION, VOLS 1-3, CONFERENCE PROCEEDINGS: BLAZING TRAILS IN ENERGY DELIVERY AND SERVICES, 2003, : 45 - 48
  • [8] PROPOSALS FOR INSTALLATION OF SINGLE-CORE CABLES - DISCUSSION
    PARR, RG
    CROCKETT, AE
    BARNES, CC
    ROLLS, TB
    THOMAS, AG
    WILSON, A
    GOOD, AJ
    FOULSHAM, N
    METCALFE, JC
    PHILBRICK, SE
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1976, 123 (01): : 73 - 75
  • [9] Power Lines Made of Many Parallel Single-Core Cables: A Case Study
    Freschi, Fabio
    Tartaglia, Michele
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2013, 49 (04) : 1744 - 1750
  • [10] Current distribution in single-core cables connected in parallel
    Du, Y
    Burnett, J
    IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2001, 148 (05) : 406 - 412