COOPERATIVE DESIGN AND OPTIMIZATION OF REACTOR COOLANT SYSTEM PIPING SUPPORTS UNDER STATIC AND DYNAMICAL LOAD CONDITIONS

被引:0
|
作者
Xiong, Fu-Rui [1 ]
Lan, Bin [1 ]
机构
[1] Nucl Power Inst China, Sci & Technol Reactor Syst Design Technol Lab, Chengdu, Sichuan, Peoples R China
基金
美国国家科学基金会;
关键词
MULTIOBJECTIVE OPTIMIZATION;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The main pipes of reactor coolant systems (RCS) are usually long flexible structures that are connected to multiple key equipment and components of the nuclear system (e.g., reactor pressure vessel, steam generator, main pump, etc.). Mechanical analysis of pipe responses at key elbows and weld seams under static and dynamical load conditions is an essential step to ensure safety and reliability of the whole RCS. Common practice to keep the structural integrity of RCS piping under dynamical load (seismic or shock load) is to impose supporting devices at various locations so that the stiffness at weak spots can be improved. Nevertheless, the introduction of supporting devices, especially the mechanical stops, may cause significant increase of thermal stress due to the block of thermal expansion path of the piping. Hence, cooperative design and optimization of RCS piping supports by jointly considering the piping responses under static and dynamical load cases becomes quite a necessity. In this paper, such an optimal design task is formulated as a multi-objective optimization problem (MOP) with the stress level at key elbows and weld seams of the main pipes as objectives; and various parameters of each supporting device as design variables. The key feature of such MOP is that the number of design variables is unknown in prior. A single support sampling strategy is first proposed to observe the influence of one supporting device. Clustering algorithms are then applied to discover patterns from the single support sampling pool. A 3-snubber-3-stop main pipe support layout is determined via unsupervised clustering algorithms. We perform the surrogate model based parameter optimization once the optimization framework is fixed. Simulation results of the optimal piping support design show good satisfactions of stress level according to ASME boiler and pressure vessel code (BPVC) under both static and dynamical load cases. The data-driven design and optimization procedures presented in this paper suit the optimal design with conflicting objectives and unclear number of design variables.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Study on Transient Hydraulic Load of Reactor Coolant System under the Condition of Reactor Coolant Pump Rotor Seizure
    Cui H.
    Tan X.
    Wang Y.
    Kuang C.
    Su S.
    Hedongli Gongcheng/Nuclear Power Engineering, 2024, 45 (01): : 230 - 236
  • [2] Effect of microstructure on failure behavior of light water reactor coolant piping under severe accident conditions
    Harada, Y
    Maruyama, Y
    Maeda, A
    Shibazaki, H
    Kudo, T
    Hidaka, A
    Hashimoto, K
    Sugimoto, J
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1999, 36 (10) : 923 - 933
  • [3] MODELING OF CHEMISTRY IN THE REACTOR COOLANT SYSTEM UNDER SEVERE ACCIDENT CONDITIONS
    CLOUGH, PN
    WHEATLEY, CJ
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1988, 195 : 127 - NUCL
  • [4] Optimization Design for Reactor Coolant Average Temperature Control System of Hualong I
    Zhang Y.
    Chen Z.
    Li Y.
    Shanghai Jiaotong Daxue Xuebao/Journal of Shanghai Jiaotong University, 2018, 52 : 26 - 30
  • [5] Dynamical strength and design optimization of pipe-joint system under pressure impact load
    Yongshou, L.
    Xindang, H.
    Youhai, Z.
    Zhufeng, Y.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART G-JOURNAL OF AEROSPACE ENGINEERING, 2012, 226 (G8) : 1029 - 1040
  • [6] An Optimization Strategy for High Efficiency and Low Axial Load Design of Hydraulic Model for Nuclear Reactor Coolant Pump
    Lu Y.
    Wang X.
    Zhou F.
    Hedongli Gongcheng/Nuclear Power Engineering, 2019, 40 (02): : 42 - 48
  • [7] Design Parameters Optimization of MGT-ORC System based on Load Demand under Off-design Conditions
    Xu, Hong Can
    Pan, Lei
    Shen, Jiong
    PROCEEDINGS OF THE 32ND 2020 CHINESE CONTROL AND DECISION CONFERENCE (CCDC 2020), 2020, : 3360 - 3365
  • [8] Design and optimization of average coolant temperature control system for the small lead-bismuth fast reactor
    Zhang, Ru
    Sun, Aodi
    Li, Muping
    Sun, Peiwei
    Wei, Xinyu
    ANNALS OF NUCLEAR ENERGY, 2025, 213
  • [9] Power distribution system design for operation under nonsinusoidal load conditions
    United States General Services, Administration, Kansas City, United States
    IEEE Trans Ind Appl, 3 (513-519):
  • [10] Experimental study on transport behavior of cesium iodide in the reactor coolant system under LWR severe accident conditions
    Miyahara, Naoya
    Miwa, Shuhei
    Gouello, Melany
    Imoto, Junpei
    Horiguchi, Naoki
    Sato, Isamu
    Osaka, Masahiko
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2020, 57 (12) : 1287 - 1296