Quantifying the mechanical and histological properties of thrombus analog made from human blood for the creation of synthetic thrombus for thrombectomy device testing

被引:19
|
作者
Merritt, William [1 ,2 ]
Holter, Anne Marie [1 ,2 ]
Beahm, Sharna [1 ,2 ]
Gonzalez, Connor [1 ,2 ]
Becker, Timothy A. [1 ,2 ]
Tabor, Aaron [2 ]
Ducruet, Andrew F. [3 ]
Bonsmann, Laura S. [1 ,2 ]
Cotter, Trevor R. [2 ]
Frenklakh, Sergey [4 ]
机构
[1] No Arizona Univ, Mech Engn Dept, Flagstaff, AZ 86011 USA
[2] No Arizona Univ, Ctr Bioengn Innovat, Flagstaff, AZ 86011 USA
[3] Barrow Neurol Inst, Phoenix, AZ 85013 USA
[4] Stryker Neurovasc Intervent Res & Dev, Fremont, CA USA
关键词
thrombectomy; stroke; device; ACUTE ISCHEMIC-STROKE; POLYMER;
D O I
10.1136/neurintsurg-2017-013675
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Background Untreated ischemic stroke can lead to severe morbidity and death, and as such, there are numerous endovascular blood-clot removal (thrombectomy) devices approved for human use. Human thrombi types are highly variable and are typically classified in qualitative terms - 'soft/red,' 'hard/white,' or 'aged/calcified.' Quantifying human thrombus properties can accelerate the development of thrombus analogs for the study of thrombectomy outcomes, which are often inconsistent among treated patients. Methods 'Soft'human thrombi were created from blood samples ex vivo (ie, human blood clotted in sample vials) and tested for mechanical properties using a hybrid rheometer material testing system. Synthetic thrombus materials were also mechanically tested and compared with the 'soft' human blood clots. Results Mechanical testing quantified the shear modulus and dynamic (elastic) modulus of volunteer human thrombus samples. This data was used to formulate a synthetic blood clot made from a composite polymer hydrogel of polyacrylamide and alginate (PAAM-Alg). The PAAM-Alg interpenetrating network of covalently and ionically cross-linked polymers had tunable elastic and shear moduli properties and shape memory characteristics. Conclusions Due to its adjustable properties, PAAM-Alg can be modified to mimic various thrombi classifications. Future studies will include obtaining and quantitatively classifying patient thrombectomy samples and altering the PAAM-Alg to mimic the results for use with in vitro thrombectomy studies.
引用
收藏
页码:1168 / 1173
页数:6
相关论文
共 3 条
  • [1] Development of physiologically relevant synthetic thrombus for use in visual analysis of in vitro mechanical thrombectomy device testing
    Berns, Holly
    Robertson, Sophia
    Lewis, Kailey
    Wells, Jesse
    Clark, Wyatt
    Becker, Timothy A.
    [J]. JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2024,
  • [2] BRIDGING-THERAPY VS MECHANICAL THROMBECTOMY ALONE: ANALYSIS AND COMPARISON OF RETRIEVED THROMBUS SIZE AND HISTOLOGICAL COMPOSITION OF 300 AIS CASES FROM CURAM RESTORE REGISTRY.
    Rossi, R.
    Fitzgerald, S.
    Mereuta, O.
    Douglas, A.
    Molina, S.
    Pandit, A.
    Gilvarry, M.
    McCarthy, R.
    Vadasz, A.
    Nagy, A.
    O'Hare, A.
    Nordanstig, A.
    Murphy, B.
    Alderson, J.
    Psychogios, K.
    Szikora, I.
    Thornton, J.
    Rentzos, A.
    Tatlisumak, T.
    Doyle, K.
    [J]. INTERNATIONAL JOURNAL OF STROKE, 2020, 15 (1_SUPPL) : 32 - 32
  • [3] Mechanical properties of clot made from human and bovine whole blood differ significantly
    Sugerman, Gabriella P.
    Bechtel, Grace N.
    Malinowska, Zuzanna
    Parekh, Sapun H.
    Rausch, Manuel K.
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2024, 154