Fluorimetric screening assay for protein carbonyl evaluation in biological samples

被引:14
|
作者
Stocker, P. [1 ]
Ricquebourg, E. [1 ]
Vidal, N. [1 ,2 ]
Villard, C. [3 ]
Lafitte, D. [3 ]
Sellami, L. [3 ]
Pietri, S. [1 ]
机构
[1] Aix Marseille Univ, CNRS, UMR 7273, ICR SMBSO, F-13397 Marseille 20, France
[2] SARL YELEN, F-13820 Ensues La Redonne, France
[3] Aix Marseille Univ, Ctr Rech Encol Biol & Oncopharmacol CRO2, INSERM, F-13385 Marseille, France
关键词
Protein carbonyls; NBDH; Oxidized BSA; Fluorescence; MALDI-TOF; OXIDATIVE STRESS; OXIDIZED PROTEINS; DIABETIC-RATS; AMINO-ACIDS; DAMAGE; IDENTIFICATION; PHENYLGLYOXAL; DIFFICULTIES; ALDEHYDES; RESIDUES;
D O I
10.1016/j.ab.2015.04.021
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Many assays are available for the detection of protein carbonyls (PCs). Currently, the measurement of PC groups after their derivatization with 2,4-dinitrophenol hydrazine (DNPH) is widely used for measuring protein oxidation in biological samples. However, this method includes several washing steps. In this context, we have developed a rapid, sensitive, and accurate fluorimetric method adapted to 96-well microplates for the convenient assessment of protein carbonyl level in biological samples. The method reported here is based on the reaction of carbonyl content in proteins with 7-hydrazino-4-nitroben zo-2,1,3-oxadiazole (NBDH) to form highly fluorescent derivatives via hydrazone formation. PCs were determined using the DNPH and NBDH assays in fully reduced bovine serum albumin (BSA) and plasma and liver homogenates obtained from healthy control rats up the addition of various amounts of HOC1-oxidized BSA (OxBSA). Using the NBDH assay, PC concentrations as low as 0.2 nmol/mg were detected with precision as low as 5%. Matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectroscopy was used to successfully identify the formation of the NBDH adducts after derivatization with standard oxidized peptides. Finally, the two methods were further used for PC determination in plasma and liver samples from diabetic and normal rats, showing that the NBDH assay can be reliably used in biological experiments. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:55 / 61
页数:7
相关论文
共 50 条
  • [1] IMPROVED FLUORIMETRIC ASSAY OF CHLOROQUINE IN BIOLOGICAL SAMPLES
    ADELUSI, SA
    SALAKO, LA
    JOURNAL OF PHARMACY AND PHARMACOLOGY, 1980, 32 (10) : 711 - 712
  • [2] Use of a biological assay as a dioxin screening assay for environmental samples.
    Chu, MD
    Brown, D
    Kishimoto, Y
    Ikeno, O
    Nomura, J
    Murakami, T
    Murata, H
    Clark, G
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2002, 224 : U541 - U542
  • [3] Fluorimetric determination of selenium in biological samples
    Rodríguez, EMR
    Alaejos, MS
    Romero, CD
    ANALYTICAL LETTERS, 1999, 32 (09) : 1699 - 1721
  • [4] HPLC-fluorimetric assay of phospholipase A2. Application to biological samples with high protein content and various reaction conditions
    Karkabounas, A.
    Kitsiouli, E. I.
    Nakos, G.
    Lekka, M. E.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (19): : 1557 - 1564
  • [5] MODIFIED FLUORIMETRIC DETERMINATION OF CHLOROQUINE IN BIOLOGICAL SAMPLES
    SCHULMAN, SG
    YOUNG, JF
    ANALYTICA CHIMICA ACTA, 1974, 70 (01) : 229 - 232
  • [6] Fluorimetric assay of interaction of protein with ferrofluids
    Mallik, Dhriti
    Mir, Aparna
    Bhattacharya, Soumya
    Nayar, Suprabha
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2011, 78 (01) : 332 - 336
  • [7] Validation of a modified fluorimetric assay for the screening of trichomonacidal drugs
    Ibanez Escribano, Alexandra
    Meneses Marcel, Alfredo
    Machado Tugores, Yanetsy
    Nogal Ruiz, Juan Jose
    Aran Redo, Vicente J.
    Escario Garcia-Trevijano, Jose Antonio
    Gomez Barrio, Alicia
    MEMORIAS DO INSTITUTO OSWALDO CRUZ, 2012, 107 (05): : 637 - 643
  • [8] Rapid fluorimetric assay for primary amine groups in water samples
    A. Sevillano Cabeza
    Y. Moliner Martinez
    C. Molins Legua
    P. Campíns Falcó
    Analytical and Bioanalytical Chemistry, 2003, 376 : 918 - 922
  • [9] CRITICAL EVALUATION OF FLUORIMETRIC ASSAY METHODS FOR MORPHINE
    CHALMERS, RA
    JACKSON, AFJ
    REVUE ROUMAINE DE CHIMIE, 1977, 22 (04) : 575 - 581
  • [10] Rapid fluorimetric assay for primary amine groups in water samples
    Cabeza, AS
    Martinez, YM
    Legua, CM
    Falcó, PC
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 376 (06) : 918 - 922