PRESAGE® as a new calibration method for high intensity focused ultrasound therapy

被引:6
|
作者
Costa, M. [1 ,2 ]
McErlean, C. [3 ]
Rivens, I. [1 ]
Adamovics, J. [4 ]
Leach, M. O. [3 ]
ter Haar, G. [1 ]
Doran, S. J. [3 ,5 ]
机构
[1] Inst Canc Res, Dept Phys, London SW3 6JB, England
[2] Fundacao Ciencia & Tecnol, Lisbon, Portugal
[3] Inst Canc Res, CRUK Canc Imaging Ctr, London SW3 6JB, England
[4] Rider Univ, Dept Chem & Biol, Lawrenceville, NJ 08648 USA
[5] Univ Surrey, Dept Phys, Guildford GU2 5XH, Surrey, England
关键词
DOSIMETER; WATER;
D O I
10.1088/1742-6596/573/1/012026
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
High Intensity Focused ultrasound (HIFU) is a non-invasive cancer therapy that makes use of the mainly thermal effects of ultrasound to destroy tissue. In order to achieve reliable treatment planning, it is necessary to characterise the ultrasound source (transducer) and to understand how the wave propagates in tissue and the energy deposition in the focal region. This novel exploratory study investigated how HIFU affects PRESAGE (R), an optical phantom used for radiotherapy dosimetry, which is potentially a rapid method of calibrating the transducer. Samples, of two different formulations, were exposed to focused ultrasound and imaged using Optical Computed Tomography. First results showed that, PRESAGE (R) changes colour on ultrasound exposure (darker green regions were observed) with the alterations being related to the acoustic power and sample composition. Future work will involve quantification of these alterations and understanding how to relate them to the mechanisms of action of HIFU.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] High intensity focused ultrasound calibration - Status and challenges
    Rivers, IH
    ter Haar, GR
    AMUM 2004: Advanced Metrology for Ultrasound in Medicine 2004, 2004, 1 : 180 - 180
  • [2] High Intensity Focused Ultrasound Surgery and Therapy
    Farahani, K.
    O'Neill, B.
    MEDICAL PHYSICS, 2014, 41 (06) : 531 - 531
  • [3] High-intensity focused ultrasound therapy
    Cheung, Vincent Y. T.
    BEST PRACTICE & RESEARCH CLINICAL OBSTETRICS & GYNAECOLOGY, 2018, 46 : 74 - 83
  • [4] High intensity focused ultrasound: A method of hemostasis
    Vaezy, S
    Martin, R
    Crum, L
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2001, 18 (04): : 309 - 315
  • [5] Anaesthesia for high intensity focused ultrasound (HIFU) therapy
    Yao, C. -L.
    Trinh, T.
    Wong, G. T. C.
    Irwin, M. G.
    ANAESTHESIA, 2008, 63 (08) : 865 - 872
  • [6] Is high-intensity focused ultrasound therapy option?
    Weiss, Johannes
    ZEITSCHRIFT FUR GASTROENTEROLOGIE, 2014, 52 (05):
  • [7] THE CALIBRATION OF TARGETING FOR AN ULTRASOUND-GUIDED HIGH-INTENSITY FOCUSED ULTRASOUND SYSTEM
    Li, Ke
    Bai, Jing-feng
    Chen, Ya-zhu
    Ji, Xiang
    PROCEEDINGS OF 2016 SYMPOSIUM ON PIEZOELECTRICITY, ACOUSTIC WAVES, AND DEVICE APPLICATIONS (SPAWDA), 2016, : 213 - 216
  • [8] Theoretical analysis of the high intensity focused ultrasound method for cancer therapy and phantom experiments
    Toda, Yasunaga
    Yamaji, Masato
    Fujii, Mamiko
    Kanai, Hiroshi
    Japanese Journal of Medical Electronics and Biological Engineering, 1998, 36 (02):
  • [9] The efficacy of a new high intensity focused ultrasound therapy for locally advanced pancreatic cancer
    Zhao, Jing
    Zhao, Fuguang
    Shi, Yulan
    Deng, Yongchuan
    Hu, Xiaoye
    Shen, Hong
    JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 2017, 143 (10) : 2105 - 2111
  • [10] The efficacy of a new high-intensity focused ultrasound therapy for metastatic pancreatic cancer
    Zhao, Jing
    Shen, Hong
    Hu, Xiaoye
    Wang, Yuebing
    Yuan, Ying
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2021, 38 (01) : 288 - 295