Extubation Failure in a Burn Intensive Care Unit: Examination of Contributing Factors

被引:4
|
作者
Rizzo, Julie A. [1 ,2 ]
Haq, Mahdi [1 ,3 ]
McMahon, Ryan A. [4 ,5 ]
Aden, James K. [4 ]
Brillhart, Daniel B. [6 ]
Cancio, Leopoldo C. [1 ]
机构
[1] US Army, Inst Surg Res, Ft Sam Houston, TX 78234 USA
[2] Uniformed Serv Univ Hlth Sci, Bethesda, MD 20814 USA
[3] Metis Fdn, San Antonio, TX USA
[4] Brooke Army Med Ctr, Ft Sam Houston, TX 78234 USA
[5] US Army, Med Ctr Excellence, Joint Base San Antonio, TX USA
[6] Darnell Army Med Ctr, Ft Hood, TX USA
来源
JOURNAL OF BURN CARE & RESEARCH | 2021年 / 42卷 / 02期
关键词
ENDOTRACHEAL INTUBATION; NOSOCOMIAL PNEUMONIA; INHALATION; RESUSCITATION; REQUIREMENTS; REINTUBATION; TRIALS; RISK;
D O I
10.1093/jbcr/iraa162
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Extubation failure is associated with negative outcomes making the identification of risk factors for failure paramount. Burn patients experience a high incidence of respiratory failure requiring mechanical ventilation. There is no consensus on the acceptable rate of extubation failure and many conventional indices do not accurately predict extubation outcomes in burn patients. The purpose of this study was to examine the rate of extubation failure in the burned population and to examine the impact of factors on extubation outcomes. Burn patients from a single center over 9 years were examined and included if they were intubated prior to arrival or within 48 hours of admission and underwent a planned extubation. From this cohort, a matched case-control analysis based on age, TBSA, and sex was performed of patients who succeeded after extubation, defined as not requiring reintubation within 72 hours, to those who failed. Characteristics and clinical parameters were compared to determine whether any factors could predict extubation failure. There was a 12.3% incidence of extubation failure. In the matched case-control analysis, the presence of inhalation injury was associated with extubation success. Higher heart rate and lower serum pH were associated with extubation failure. ANCOVA analysis demonstrated that a sodium trending higher before extubation was associated with more successes, possibly indicative of a lower volume status. Classic extubation criteria do not accurately predict extubation outcomes in burn patients; analysis of other parameters may be able to provide better predictions. A constellation of these parameters needs to be studied prospectively.
引用
收藏
页码:177 / 181
页数:5
相关论文
共 50 条
  • [1] Risk Factors For Extubation Failure In Intensive Care Unit Patients
    Saddy, F.
    Thompson, A.
    Serafim, R. B.
    Carnevale, R.
    Charris, N.
    Pantoja, J. G.
    Rocco, P. R. M.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2011, 183
  • [2] The Incidence and Outcome of Extubation Failure in Burn Intensive Care Patients
    Smailes, Sarah T.
    Martin, Rebecca V.
    McVicar, Andrew J.
    [J]. JOURNAL OF BURN CARE & RESEARCH, 2009, 30 (03): : 386 - 392
  • [3] Extubation failure in intensive care unit: Predictors and management
    Kulkarni, Atul P.
    Agarwal, Vandana
    [J]. INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2008, 12 (01) : 1 - 9
  • [4] Factors associated with extubation failure in an intensive care unit: a case-control study
    Arcanjo, Ana Beatriz Braga
    Beccaria, Lucia Marinilza
    [J]. REVISTA LATINO-AMERICANA DE ENFERMAGEM, 2023, 31
  • [5] Associated factors to extubation failure in the term newborns from a neonatal intensive care unit
    Antonio Tapia-Rombo, Carlos
    Edith Cortes-Ortiz, Reyna
    Uscanga-Carrasco, Herminia
    Tena-Reyes, Daniel
    [J]. REVISTA DE INVESTIGACION CLINICA-CLINICAL AND TRANSLATIONAL INVESTIGATION, 2011, 63 (05): : 484 - 493
  • [6] Factors associated with extubation failure in intensive care unit: a case-control study
    Arcanjo, Ana Beatriz Braga
    Beccaria, Lucia Marinilza
    [J]. REVISTA LATINO-AMERICANA DE ENFERMAGEM, 2023, 31
  • [7] Factors associated with extubation failure in an intensive care unit: a case-control study*
    Arcanjo, Ana Beatriz Braga
    Beccaria, Lucia Marinilza
    [J]. REVISTA LATINO-AMERICANA DE ENFERMAGEM, 2023, 31
  • [8] Endoscopic management of pediatric extubation failure in the intensive care unit
    Liu, Yupeng
    Wu, Wenjin
    Huang, Qi
    [J]. INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2020, 139
  • [9] Outcomes of extubation failure in medical intensive care unit patients
    Thille, Arnaud W.
    Harrois, Anatole
    Schortgen, Frederique
    Brun-Buisson, Christian
    Brochard, Laurent
    [J]. CRITICAL CARE MEDICINE, 2011, 39 (12) : 2612 - 2618
  • [10] Prediction of extubation failure in medical intensive care unit patients
    Saugel, Bernd
    Rakette, Philipp
    Hapfelmeier, Alexander
    Schultheiss, Caroline
    Phillip, Veit
    Thies, Philipp
    Treiber, Matthias
    Einwaechter, Henrik
    von Werder, Alexander
    Pfab, Rudi
    Eyer, Florian
    Schmid, Roland M.
    Huber, Wolfgang
    [J]. JOURNAL OF CRITICAL CARE, 2012, 27 (06) : 571 - 577