Where Is the Distal Fracture Line Location of Dorsally Displaced Distal Radius Fractures?

被引:20
|
作者
Baumbach, Sebastian Felix [1 ]
Schmidt, Reinhard [1 ]
Varga, Peter [2 ]
Heinz, Thomas [1 ]
Vecsei, Vilmos [1 ]
Zysset, Philippe K. [2 ]
机构
[1] Med Univ Vienna, Dept Trauma Surg, A-1090 Vienna, Austria
[2] Vienna Univ Technol, Inst Lightweight Design & Struct Biomech, A-1040 Vienna, Austria
关键词
distal radius fracture; HR-pQCT; osteoporosis; biomechanical fracture model; GEOMETRIC-PROPERTIES; STRENGTH PREDICTION; EXTERNAL FIXATION; BONE-DENSITY; FOREARM; STABILITY; COLLES; PLATE; MODEL; LOAD;
D O I
10.1002/jor.21268
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
No consensus currently exists on the facture location of dorsally displaced distal radius fractures (DRFs). We present a systematic evaluation of the distal fracture line (DFL) location of DRFs and possible influencing factors. Determining the average location of DRFs provides a basis for developing more sensitive tests to determine bone strength using a variety of imaging techniques and for developing improved biomechanical models to test fracture characteristics and surgical implants. Initial radiographs of 157 DRFs dorsally displaced DRFs in patients aged 40-74 years were identified, patient and trauma specific data were collected, and standard radiographic measurements and (AO) fracture classification were performed. The dorsal and palmar DFL locations relative to the corresponding apex of the lunate facet were measured. The DFL was located dorsally 7.9 +/- 2.7 mm and palmarly 11.7 +/- 3.9 mm proximal to the corresponding lunate fossa apex. The dorsal DFL was significantly distal to the palmar one (p<0.001), but the two did not correlate (r(2) = 0.018,p = 0.095). DFL location was independent of age, energy of the fall, and fracture complexity. (C) 2010 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 29:489-494, 2011
引用
收藏
页码:489 / 494
页数:6
相关论文
共 50 条
  • [1] Palmar plating for dorsally displaced fractures of the distal radius
    Kamano, M
    Honda, Y
    Kazuki, K
    Yasuda, M
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (397) : 403 - 408
  • [2] Dorsally displaced fractures of the distal radius A CRITICAL APPRAISAL OF THE DRAFFT (DISTAL RADIUS ACUTE FRACTURE FIXATION TRIAL) STUDY
    Fullilove, S.
    Gozzard, C.
    BONE & JOINT JOURNAL, 2016, 98B (03): : 298 - 300
  • [3] Fixation of Dorsally Displaced Distal Radius Fractures With Volar Plate
    Othman, Ahmed Y.
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2009, 66 (05): : 1416 - 1420
  • [4] Volar neutralization plate fixation of dorsally displaced distal radius fractures
    Constantine, KJ
    Clawson, MC
    Stern, PJ
    ORTHOPEDICS, 2002, 25 (02) : 125 - 128
  • [5] Volar fixation for dorsally displaced fractures of the distal radius: A preliminary report
    Orbay, JL
    Fernandez, DL
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2002, 27A (02): : 205 - 215
  • [6] Initial experience with the Forte plate for dorsally displaced distal radius fractures
    Finsen, V
    Aasheim, T
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2000, 31 (06): : 445 - 448
  • [7] Dorsally angulated fractures of the distal radius
    Deakin, D. E.
    Deshmukh, S. C.
    TRAUMA-ENGLAND, 2010, 12 (01): : 21 - 29
  • [8] Kirschner Wire Fixation in Dorsally Displaced Distal Radius Fractures: A Biomechanical Evaluation
    Sanders, Liam
    Johnson, Nick
    Dias, Joseph J.
    JOURNAL OF WRIST SURGERY, 2022, 11 (01) : 21 - 27
  • [9] Internal fixation of dorsally displaced fractures of the distal part of the radius - A biomechanical analysis of volar plate fracture stability
    Willis, Andrew A.
    Kutsumi, Keiji
    Zobitz, Mark E.
    Cooney, William P., III
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (11): : 2411 - 2417
  • [10] LOCKING PALMAR PLATE FIXATION FOR DORSALLY DISPLACED FRACTURES OF THE DISTAL RADIUS: A PRELIMINARY REPORT
    Moriya, Koji
    Saito, Hidehiko
    Takahashi, Yuji
    Ohi, Hiroyuki
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2011, 16 (03): : 363 - 369